Heart Valve Replacement With Ionescu-Shiley Valves: Report Of 265 Cases

IonescuShiley 판막 사용 심장판막이식술[265례 보고]

  • Published : 1981.12.01

Abstract

In this department 504 cases of valve replacement were done since 1968 to the end of October 1981. Since October 31, 1978 to the end of October 1981 ,333 Ionescu-Shiley bovine pericardial xenograft bioprosthetic cardiac valves were replaced in 265 patients. There were 149 males and 116 female. Ages ranged from 2 to 63 years with 25 cases under 15 years of age. Among 265 cases of Ionescu valve replacement there were 157 MVR, 36 VAR, 6 TVR, 45 MVR+ AVR, 16 MVR+TVR and 5 MVR+AVR+TVR cases with mortality of 5.7%, 8.3%, 16.7%, 8.9%, 18.8% and 20% for each group respectively. Over all mortality rate in 265 Ionescu valve replacement cases was 7.9% with 21 total deaths. Main causes of operative deaths were due to LCOS in 7, bleeding in 5, arrhythmia in 3, air embolism in 2,and heart block in 2 cases. There were 12 late complications with 6 deaths. Over all long-term survival rate was 89.8%. MVR showed the highest long-term survival rate with 92.4%, and MVR+AVR+TVR the lower with 80% lower with 80%.Average follow-up period was 14 month duration. Twenty five congenital anomaly cases were operated with Ionescu-valve replacement that consisted of 7 VSD+AI, and 5 Ebstein anomaly cases with over all operative mortality of 16% and late mortality of 14.3% among 21 operative survivors. There were 25 Ionescu valve replacement cases in pediatric patients under the age of 15 years, with 4 operative deaths. Fourteen MVR, 7 AVR, and 3 TVR cases were found. Even though long-term follow-up study was short in postoperative period with total of 33~.0 months among 244 operative survivors ranging one to 36 months, the late survivors showed beneficial long-term results two thromboembolic episodes in 244 patients were found. More cases and longer term follow-up study are warranted for valve replacement in pediatric and TVR cases with Ionescu-valves which have advantageous hemodynamic structures compared with other bio-prosthetic heart valves.

Keywords