Journal of ILASS-Korea (한국분무공학회지)
- Volume 4 Issue 3
- /
- Pages.42-52
- /
- 1999
- /
- 1226-2277(pISSN)
- /
- 2288-9051(eISSN)
Evaluation of Thermal Utilization of Dousing System in PHWR Nuclear Power Plant
Abstract
An effectiveness of thermal utilization of a dousing system in the 600 MW PHWR Nuclear Power Plant has been evaluated. The behavior and conditions of water droplet sprayed in a postulated accident conditions in containment configuration has been calculated. In this calculation, two pressure conditions with the consideration of obstruction area and containment wall effect has been established : one being the minimum containment pressure of 7 kPa(g) encountered for dousing shut off and the other being the containment design pressure 124 kPa(g). The results revealed that the effectiveness of the thermal utilization ranges from 93% to 97%. In the analysis on two cases without/with side wall effect in the containment building, the thermal utilization decreases with obstruction area from 89% to 85%, which satisfies the design criteria set for the containment pressure against the accident condition.