Removal of Organic Pollutants from Aqueous Solution by Hollow Fiber Module

중공사모듈에 의한 수용액으로부터 유기오염물의 제거

  • 유홍진 (순천향대학교 신소재화학공학부)
  • Published : 2003.06.01

Abstract

This study is to remove several organic pollutants from wastewater by non-dispersive membrane solvent extraction technique. The distribution coefficients of several solvents were determined and the experimental system was operated counter-currently and cocurrently with respect to the aqueous phase and solvent. In these experiments, as the flow rate of aqueous solution inclosed, due to being shortened contact time to solvent, the rate of removal of organic pollutants decreased and as the flow rate of solvent increased, the rate of removal increased. Meanwhile, the rate of removal of organic pollutants for the countercurrent flow system was higher than that for the occurrent flow system.

본 연구는 폐수로부터 몇 가지의 유기오염물(Phenol, 2-Chlorophenol, Nitrobenzene)을 비분산 용매추출법으로 동시 제거하는 실험이다. 몇 가지의 용매(MIBK, IPAc, Hexane)에 대하여 분배계수를 구하였고, 용매와 폐수사이의 향류와 병류 흐름에 의한 추출 실험을 하였다. 수용액상의 유량이 증가함에 따라 용매와의 접촉시간이 짧아져 제거율이 떨어지고, 용매의 유량이 증가함에 따라 제거율이 증가함을 알 수 있었다. 그리고 병류보다는 향류에서 유기오염물의 제거율이 증가하는 것을 알 수 있었다. 이러한 결과를 토대로 유기오염물만이 아닌 다른 중금속 오염물 둥도 처리할 수 있는 산업용 폐수처리장치의 개발을 위한 기초자료로 쓰일 수 있다.

Keywords