급수가열기 추기노즐의 개선된 충격판 모델에 관한 연구

A Study on Advanced Impinging Baffle Model in Extraction Nozzle of a Feedwater Heater

  • 이우 ((주)대지금속 기술연구소) ;
  • 황경모 (한국전력기술(주) 재료기술연구그룹) ;
  • 김경훈 (경희대학교 테크노공학대학 기계 공학과 (산학협력기술연구원 원전 운영기술고도화센터))
  • 발행 : 2007.03.31

초록

Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle - installed downstream of the high pressure turbine extraction steam line - inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes the comparisons between the numerical analysis results using the FLUENT code and the down scale experimental data in an effort to determine root causes of the shell wall thinning of the high pressure feedwater heaters. The numerical analysis and experimental data were also confirmed by actual wall thickness measured by an ultrasonic test.

키워드