Evaluation of High Order Statistical Parameter for Electrochemical Noise Analysis

  • Published : 2008.10.01

Abstract

High order statistical parameters were evaluated using the electrochemical noise data collected during corrosion of type 430 stainless steel coupled to a inert, platinum electrode in 3.5% NaCl solution. High order statistical parameters are shown to predict uniform corrosion properly. However, Localization index, skewness of current, kurtosis and skewness of potential are capable of predicting pitting corrosion only when the transients are large with long life time. Of the high order statistical parameters evaluated, kurtosis of current is found to be the most sensitive parameter for detecting uniform and pitting corrosion.

Keywords

References

  1. J. L. Dawson, ASTM STP 1277, p. 3, 1996
  2. J. F. Chen and W. F. Bogaerts, Corrosion, 52, 1218 (1996)
  3. J. F. Chen, J. Shadley, E. F. Rybicki, and W. F. Bogaerts, Corrosion '99, paper no. 193, NACE (1999).
  4. A. N. Rothwell and D. A. Eden, Corrosion '92, paper no. 223, NACE (1992)
  5. A. N. Rothwell, G. L. Edgemon, and G. E. C. Bell, Corrosion '99, paper no. 192, NACE (1999)
  6. M. Hashimoto, S. Miyajima, and T. Murata, Corrosion Sci., 33, 917 (1992) https://doi.org/10.1016/0010-938X(92)90055-8