Heat Transfer Characteristics by the Right Angled Triangle Rod Array in Impinging Air Jet System

충돌공기제트시스템에서 직삼각형로드에 의한 열전달특성

  • 금성민 (한라대학교 기계자동차공학부)
  • Published : 2008.03.31

Abstract

This experimental study was carried out to examine the heat transfer characteristics of impinging air jet on a flat plate with a set of right angled triangle rods. Each right angled triangle rod in the array was positioned normal to the flow direction and parallel to the flat plate surface. The clearances from a right angled triangle rod to flat plate surface (C=1, 2 and 4 mm) and the distance from nozzle exit to flat plate (H=100 and 500 mm) were changed for the pitch between each right angled triangle rods (P=40 mm). As a result, heat transfer shows best performance at the clearance of C=1 mm, in case clearance changed, and the average heat transfer enhancement rate increased up to 47% compared to the result of a flat plate without a right angled triangle rod.

Keywords