A Study of 2-dimensional X-ray Detector using Monte Carlo Simulation

몬테 카를로 시뮬레이션을 이용한 2차원 X-선 검출기에 대한 연구

  • Shin, Hyoung-Sup (Dept. of Electronics and Electrical Engineering, Dankook University) ;
  • Lee, Hak-Jae (Dept. of Radiologic Science, Korea University) ;
  • Lee, Ki-Sung (Dept. of Radiologic Science, Korea University) ;
  • Kang, Jung-Won (Dept. of Electronics and Electrical Engineering, Dankook University)
  • 신형섭 (단국대학교 전자전기공학과) ;
  • 이학재 (고려대학교 방사선과학과) ;
  • 이기성 (고려대학교 방사선과학과) ;
  • 강정원 (단국대학교 전자전기공학과)
  • Received : 2010.11.30
  • Accepted : 2010.12.17
  • Published : 2010.12.31

Abstract

X-ray absorption rate and multiplication factor of X-ray detector were calculated with Garfield code. High Z (= atomic number) was important factor to increase the absorption rate but low Z is also important to increase the multiplication. Five different gas composition were examined under the condition of 1400 V bias and 400 um gap. Xe 100% gas showed the highest absorption rate and He 96% + isobutene 4% showed the highest multiplication.

Keywords

References

  1. Granfors, P. R. and Albagli, D., "Scintillator-based flat panel x-ray imaging detectors," J. of the SID, 17(6), pp. 535-542, 2009
  2. Zentai, G., "Photoconductor-based (direct) large-area x-ray imagers," J. of the SID, 17(6), pp. 543-550, 2009
  3. Yun, M., Cho, S., Oh, K., Kim, M., Jung, S., Jang, G., Heo, S., Kwon, C. and Nam, S., "Measurement of the properties of a flat panel gas X-ray detector," Nuclear Instruments and Methods in Physics Research A, 607, pp. 162-165, 2009 https://doi.org/10.1016/j.nima.2009.03.174
  4. Friedman, P. S., Ball, R., Chapman, J. W., Levin, D. S., Weaverdyck, C., Zhou, B., Benhammou, Y., Etzion, E., Moshe, M. B., Silver, Y., Beene, J. R. and Varner Jr., R. L., "Large-area plasma-panel radiation detectors for nuclear medicine imaging to homeland security and the super large hadron collider," Proc. SID, 10 Digest, pp. 1080-1083, 2010
  5. Knoll, G. F., Radiation detection and Measurement 3rd ed, John Wiley & Sons, pp. 129-217, 2000
  6. Veenhof, R., Garfield, a drift-chamber simulation program, W5050, 1999
  7. . http://garfield.web.cern.ch/garfield/