DOI QR코드

DOI QR Code

국내 커튼월 시스템의 기밀성능 요구수준 및 향상방안에 관한 연구

A Study on the Air-tightness Criteria and Performance Improvement Methods of Domestic Curtain-wall Systems

  • 투고 : 2011.12.01
  • 발행 : 2012.03.25

초록

Curtain-wall systems in office buildings have repeated joints between units, which cause unintentional infiltration. It means that air-tightness of curtain-wall systems is directly related to building energy performance. Many countries have already enhanced air-tightness performance demands through Energy Code. In this study, a variety of air-tightness performance criteria and mock-up lab test results of curtain wall systems were analyzed. As results, air-tightness performance criteria for curtain-wall systems are suggested as follows. DIN EN 12153 and DIN EN 12207 are used as a comparison tool to analyze present states of fixed lights and opening lights in domestic buildings with curtain wall systems. According to the analyst, we suggested that Class A4 is suitable for fixed lights and Class 4 is suitable for opening lights of curtain wall system.

키워드

과제정보

연구 과제 주관 기관 : 이화여자대학교

참고문헌

  1. 국토해양부 고시 제 2010-1031호, 건축물의 에너지절약 설계기준, 2010
  2. 권오현, Blower Door를 이용한 국내 주거용 건물의 기밀도 실측 사례 분석, 대한건축학회논문집, 제26권 제7호, 2010.07
  3. 구성한, 조재훈, 여명석, 김광우, 실측을 통한 초고층 주거건물의 기밀도 특성에 관한 연구, 대한건축학회 학술발표대회 논문집, pp. 754-757, 2004.04
  4. 문현준, 최민석, 박진우, 유승호, 이준서, 초고층 주거건물에서의 차압 및 기밀성능 측정 연구, 한국건축친환경설비학회 학술발표대회논문집, pp. 199-202, 2009
  5. 박선효, 원종서, 조재훈, 기밀 시공관리에 따른 기밀도 현황 연구, 대한건축학회 춘계학술발표대회 논문집, 제7권 제1호, 2007.03
  6. 석호태, 김장한, 정만석, 초고층 주거건물의 에너지 성능 분석에 관한 연구, 한국주거학회논문집, 제15권 제4호, pp. 35-44, 2004.08
  7. 이광호, 김상민, 박용후, 문장수, 손장열, 초고층 주상복합 아파트의 기밀성능 및 연돌효과 특성에 관한 연구, 대한건축학회논문집, 제21권 제12호, pp. 279-286, 2005. 12
  8. 조재훈, 초고층 주거건물에서의 단위세대 기밀성능 측정 및 평가, 대한건축학회논문집, 제26권 제10호, pp. 337-344, 2010.10
  9. 지식경제부 기술표준원, KS F 2292, 창호의 기밀성 시험방법, 2008
  10. Building Regulations Part L2A Conservation of fuel and power in new buildings other than dwellings, 영국, 2006
  11. ASTM, ASTM E 283, Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors under Specified Pressure Difference Across the Specimen, 2004
  12. DIN EN 12152 : 2002 Curtain walling-Air Permeability Performance Requirements and Classification, 2002
  13. Singapore Standard SS381:1996 Materials and performance Tests for Aluminium Curtain Walls, 1996
  14. AAMA, AAMA 501-05 Methods of Tests for Exterior Walls, 2005
  15. AAMA, AAMA 503-03 Voluntary Specification for Field Testing of Storefronts, Curtain Walls and Sloped Glazing Systems, 2003
  16. CWCT(Center for Window & Cladding Technology), Standard and Guide to Good Practice for Curtain Walling, 1996
  17. IECC Envelope Provisions, Section 502 Building Envelope Requirements, 2009
  18. Washington State Legislature, WAC 51-11-1314 Air Leakage, Section 1314.2, 2010
  19. MNECB(Model National Energy Code for Buildings), Energy efficiency measures-Commercial, 2010
  20. National Standard of Canada, CAN / CSA-A440-00 Windows, 2007
  21. ASHRAE, ASHRAE 90.1-Energy Standard for Buildings Expect Low-Rise Residential Buildings -Section 5. Building Enevelope, 2007
  22. NFRC(Nationsal Fenestration Rating Council Incorporated)400, Procedure for Determining Fenestration Product Air Leakage, 2004
  23. DIN EN 12207 Windows and Doors Air Permeability Classification, 1999