Evaluations of corrosion resistance of Ni-Cr plated and Zn-plated Fe Substrates Using an Electrolytic Corrosion Test

전해부식시험을 이용한 니켈-크롬도금강판 및 아연도금강판의 내식성 비교평가시험

  • Lee, Jae-Bong (School of Advanced Materials Engineering, Kookmin University) ;
  • Kim, Kyung-Wook (School of Advanced Materials Engineering, Kookmin University) ;
  • Park, Min-Woo (School of Advanced Materials Engineering, Kookmin University) ;
  • Song, Tae-Jun (School of Advanced Materials Engineering, Kookmin University) ;
  • Lee, Chae-Seung (School of Advanced Materials Engineering, Kookmin University) ;
  • Lee, Eui-Jong (Korea Testing Laboratory) ;
  • Kim, Sang-Yeol (Korea Testing Laboratory)
  • 이재봉 (국민대학교 공과대학 신소재 공학부) ;
  • 김경욱 (국민대학교 공과대학 신소재 공학부) ;
  • 박민우 (국민대학교 공과대학 신소재 공학부) ;
  • 송태준 (국민대학교 공과대학 신소재 공학부) ;
  • 이채승 (국민대학교 공과대학 신소재 공학부) ;
  • 이의종 (한국산업기술시험원) ;
  • 김상열 (한국산업기술시험원)
  • Received : 2013.02.21
  • Accepted : 2013.02.27
  • Published : 2013.02.15

Abstract

An Eectrolytic Corrosion(EC) test method was evaluated by the comparison with Copper Accelerated Acetic Salt Spray(CASS) and Neutral Salt Spray(SS) tests. Those methods were applied in order to evaluate corrosion resistance of Ni-Cr plated and Zn-plated Fe substrates. The correlations between results obtained by different test methods were investigated. Results showed that the electrochemical method such as the EC test method was superior to the conventional methods such as CASS and SS, in terms of the quantitative accuracy and the test-time span. Furthermore, the EC test method provided the useful means to estimate the initiation of corrosion of each layer by monitoring the rest potentials of the coated layers such as Ni, Cr, and Zn on Fe substrate. With regard to test time spans, the EC test provided the 78 times and 182 times faster results than the CASS test in cases of $Fe+5{\mu}m$ $Ni+0.5{\mu}m$ Cr and $Fe+20{\mu}m$ $Ni+0.5{\mu}m$ Cr respectively, while the EC test was 85 times faster results than the Salt Spray test in the case of $Fe+20g/m^2$ Zn. Therefore, the EC test can be the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as the SS test and the CASS.

Keywords

References

  1. KS D 8334, Methods of Corrosion Resistance Test of Metallic Coatings (1990).
  2. KS D 9502, Methods of Neutral Salt Spray Testing (2009).
  3. KS D 9504, Copper Accelerated Acetic Acid Salt Spray Testing Methods (1983).
  4. ASTM B 627-84, Standard Test Methods for Electrolytic Corrosion Testing (EC test) (1992).
  5. ISO 4539, Electrodeposited chromium coatings-Electrolytic corrosion testing (EC test) (1980).
  6. R. L. Saur and R. P. Basco, Plating, 53, 35 (1966).
  7. R. L. Saur and R. P. Basco, Plating, 53, 320 (1966).
  8. R. L. Saur and R. P. Basco, Plating, 53, 981 (1966).
  9. R. L. Saur, Plating, 54, 393 (1967).