맥진 깊이 판단을 위한 실시간 압력 측정기

Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse

  • 조정호 (부산대학교 한의학전문대학원 한의공학연구실) ;
  • 김대복 (부산대학교 한의학전문대학원 한의공학연구실) ;
  • 김기왕 (부산대학교 한의학전문대학원 한의공학연구실)
  • Cho, Jong Ho (Division of Applied Medicine, School of Korean Medicine, Pusan National University) ;
  • Kim, Dae Bok (Division of Applied Medicine, School of Korean Medicine, Pusan National University) ;
  • Kim, Gi Wang (Division of Applied Medicine, School of Korean Medicine, Pusan National University)
  • 투고 : 2013.05.07
  • 심사 : 2013.06.18
  • 발행 : 2013.06.25

초록

In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin($10{\mu}m$) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.

키워드

참고문헌

  1. 임양근. 맥진(진단학 아틀라스3). 서울, 도서출판 정담, pp 11-12, 2003.
  2. 홍성천, 금경수, 황우준, 이시형,전병욱. 한방의료정보화 현황 및 발전방안에 관한 연구. 대한한의정보학회지 10(2):114-188, 2004.
  3. Hyunho Kim, Jong Yeol Kim, Young-Jae Park, Young-Bae Park, Development of pulse diagnostic devices in Korea, Integrative Medicine Research. 2: 7-17, 2013, https://doi.org/10.1016/j.imr.2013.01.003
  4. 金鍾悅, 金敬堯高, 高基德, 맥진기의 문제점과 개선방안에 관한 연구. 대한한의진단학회지 3(1):28-36, 1999
  5. 김경철, 신순식, 강희정, 차철용, 맥진의 현대적인 객관화 연구를 위한 기반조사. 대한동의생리학회지 17(5):1147-1150, 2003.
  6. Rayburn, Ray A. Eargle's The Microphone Book. 2nd rev:Elsevier. pp 112-114, 2011.
  7. 이향숙, 이용범, 신용섭, 김희주, 서정철, 이준무, 이혜정, 최선미. 팔체질의학 맥진의 신뢰성 연구. 대한경락경혈학회지 22(4):1-8, 2005.