DOI QR코드

DOI QR Code

An Eight-directional Airborne Chloride Collection Method for the Application of an Appropriate Anti-corrosive Material for Each Side of a Building

  • Cho, Gyuhwan (Fire Research Institute, Korea Institute of Civil Engineering and Building Technology) ;
  • Yeo, Inhwan (Fire Research Institute, Korea Institute of Civil Engineering and Building Technology) ;
  • Park, Dongcheon (Department Architecture Ocean Space, Korea Maritime and Ocean University)
  • 투고 : 2015.12.28
  • 심사 : 2016.05.31
  • 발행 : 2016.06.30

초록

To secure the anticorrosive performance of structures in the oceanic environment it is necessary to select appropriate finishing materials and thickness of cover. However, airborne chloride deposition varies depending on the collector used, and it is difficult to select appropriate finishing materials. For this reason, an eight-directional collector is proposed in this study through reviewing the differences between existing airborne chloride collectors and the new one. To analyze airborne chloride deposition according to the direction from which it flows and verify the performance of the collector proposed in this study, airborne chlorides were deposited on the collector for one year at five different locations in an oceanic environment. From the experiment, it was verified that in terms of direction, there were differences in airborne chloride deposition of up to more than 1.5 times. Based on these research findings, the anti-corrosive method applied can be different for each side of a building's structure, and this is believed to serve as an effective and systemic chloride resistance design.

키워드

참고문헌

  1. Akiyama, M., Frangopol, D. M., & Suzuki, M. (2012). Integration of the effects of airborne chlorides into reliability-based durability design of reinforced concrete structures in a marine environment. Structure and Infrastructure Engineering, 8(2): 125-134. https://doi.org/10.1080/15732470903363313
  2. Meira, G. R., Andrade, M. C., Padaratz, I. J., Alonso, M. C., &Borba, J. C. (2006).Measurements and modelling of marine salt transportation and deposition in a tropical region in Brazil. Atmospheric Environment, 40(29): 5596-5607. https://doi.org/10.1016/j.atmosenv.2006.04.053
  3. Jongseok, Lee. (2006). Estimation of the surface chlorides for concrete structures in the seashore considering airborne chlorides.Doctorate thesis.Seoul:HANYANG University.
  4. Cole, I. S., Ganther, W. D., Paterson, D. A., King, G. A., Furman, S. A., & Lau, D. (2003). Holistic model for atmospheric corrosion: Part 2-Experimental measurement of deposition of marine salts in a number of long range studies. Corrosion Engineering, Science and Technology, 38(4): 259-266. https://doi.org/10.1179/147842203225008886
  5. Fitzgerald, J. W. (1991). Marine aerosols: A review. Atmospheric Environment. Part A. General Topics, 25(3): 533-545. https://doi.org/10.1016/0960-1686(91)90050-H
  6. Cole, I. S., & Paterson, D. A. (2004). Holistic model for atmospheric corrosion Part 5-Factors controlling deposition of salt aerosol on candles, plates and buildings. Corrosion engineering, Science and Technology, 39(2): 125-130. https://doi.org/10.1179/147842204225016949
  7. Hossain, K. M. A., Easa, S. M., &Lachemi, M. (2009).Evaluation of the effect of marine salts on urban built infrastructure.Building and Environment, 44(4): 713-722. https://doi.org/10.1016/j.buildenv.2008.06.004
  8. JIS Z 2381: General requirements for atmospheric exposure test (2001)
  9. Katawaki, K., Moriya, S., &Minosaku, K. (1985). Characteristics and measurement of airborne chloride(test with recent measurement). Pre-stress Concrete, 27(1): 68-73.
  10. ASTM G140: standard test method for determining atmospheric chloride deposition rate by wet candle method, ASTM International, West Conshohocken, PA, USA (1996)
  11. Lee, J. S., & Moon, H. Y. (2006).Salinity distribution of seashore concrete structures in Korea.Building and environment, 41(10), 1447-1453. https://doi.org/10.1016/j.buildenv.2005.05.030
  12. Cho, G. H., Lee, Y. J., & Park, D. C., (2014).Evaluation of the Distribution Characteristics of Airborne Chlorides by Eight- directional collection method.Korea Institute of Building Construction, 14(1), 98-99.
  13. Park, D. C., Ahn, J. C., & Kim, W. J. (2011). Development of Multidirection Incoming Salt Collector that Excludes Backward Wind. Journal of the Korea Institute of Building Construction, 11(6), 627-633. https://doi.org/10.5345/JKIBC.2011.11.6.627
  14. Kazama, H., & Yamada, Y. (2004).An advection-diffusion analysis of airborne chloride (Durability).Proceedings of Japan Concrete Institute, 26(1): 795-800.