DOI QR코드

DOI QR Code

겨울철 공동주택에서 붙박이장 내 보조난방장치를 활용한 결로 저감 효과 평가

Assessment of Utilization of Auxiliary Heating Device for Prevention of Condensation in Built-in Furniture in Winter

  • 이현화 (이화여자대학교 대학원) ;
  • 임재한 (이화여자대학교 건축도시시스템공학과) ;
  • 송승영 (이화여자대학교 건축도시시스템공학과)
  • 투고 : 2017.09.18
  • 심사 : 2017.11.04
  • 발행 : 2017.12.26

초록

Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions and surface temperature around the built-in furniture were measured during winter season. In this research, we analyzed thermal conditions for built-in furniture which were applied and not applied auxiliary heating device. In results, it is important to consider increasing surface temperature for using heater and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

키워드

과제정보

연구 과제 주관 기관 : 국토교통부

참고문헌

  1. Hwang, H. J., Kim, J. Y., & Lee, J. S. (2011). A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings, LHI journal 2(3), 269-276
  2. Hwang, H. J., Kim, G. T., Yoo, J. H., & Hwang, I. T. (2015). An Improvement of the Criteria for the Prevent Condensation in Apartment Houses, Journal of KIAEBS, 9(4) 319-324
  3. Kim, G. T., Kim, J. Y., Hwang, H. J., & Kim, K. S. (2014). The Design Criteria of the Indoor Temperature and Humidity for the Prevent Condensation of Small Apartment Buildings, LHI journal 5(4), 291-296
  4. Lee, H. H., Oh, H. R., Lim, J. H., & Song, S. Y. (2016). Evaluation on the Thermal Environment for Condensation Problem Diagnosis around Built-in Furniture of Apartment Buildings in Winter, Journal of the Architectural Institute of Korea Planning & Design, 32(7), 131-140. https://doi.org/10.5659/JAIK_PD.2016.32.7.131
  5. Lee, H. H., Oh, H. R., Lim, J. H., & Song, S. Y. (2016). Evaluation of the thermal environment for condensation and mold problem diagnosis around built-in furniture in Korean apartment buildings during summer and winter, Energy Procedia, 96, 601-612. https://doi.org/10.1016/j.egypro.2016.09.108
  6. Oh, H. R., Lee, H. H., Lim, J. H., & Song, S. Y. (2017). Evalution of Condensation Prevention for Condensation Vurnerable Areas around Built-in Wardrobe of Apartment Buildings, Journal of the Architectural Institute of Korea, 33(6), 87-94 https://doi.org/10.5659/JAIK_PD.2017.33.3.87
  7. Oh, H. R., Lee, H. H., Lim, J. H., & Song, S. Y. (2016). Performance Evaluation of Condensation Resistance inside Built-in Furniture Installed Supplemental Heating Device on Existing Apartment Buildings, Proceeding of the Architectural Institute of Korea, 517-518
  8. MOLIT (2016). Design standard for preventing condensation in apartment buildings, Ministry of Land, Infrastructure and Transport, Notification No. 2016-835.
  9. MOLIT (2016). Regulations on Housing Construction Standards, Ministry of Land, Infrastructure and Transport, Notification No. 27830.
  10. MOLIT (2015). Building Energy Savings Criteria, Ministry of Land, Infrastructure and Transport, Notification No. 2015-1108.
  11. KISTEC (2016), The Casebook of Condensation Problem and Maintenace about Apartment Buildings, Korea Infrastructure Safety Corporation
  12. Jeong, J. E. (2007), A Study on the Soheme to Maintain the Flatness of MDF According by painting and by thiokness to the Environment Humidity, Journal of the Korean Institute of Interior Design 16(5), 98-106