Concomitant Right Ventricular Outflow Tract Cryoablation during Pulmonary Valve Replacement in a Patient with Tetralogy of Fallot

  • Shin, Hong Ju (Division of Cardiovascular Surgery, Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Song, Seunghwan (Division of Cardiovascular Surgery, Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Shin, Yu Rim (Division of Cardiovascular Surgery, Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Park, Han Ki (Division of Cardiovascular Surgery, Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Park, Young Hwan (Division of Cardiovascular Surgery, Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine)
  • Received : 2016.03.21
  • Accepted : 2016.07.02
  • Published : 2017.02.05

Abstract

A 38-year-old female patient with a history of tetralogy of Fallot repair at 10 years of age underwent pulmonary valve replacement with a mechanical prosthesis, tricuspid annuloplasty, and right ventricular outflow tract cryoablation due to pulmonary regurgitation, tricuspid regurgitation, and multiple premature ventricular contractions with sustained ventricular tachycardia. After surgery, she had an uneventful postoperative course with arrhythmia monitoring. She was discharged without incident, and a follow-up Holter examination showed a decrease in the number of ventricular ectopic beats from 702 to 41.

Keywords

References

  1. Oosterhof T, Hazekamp MG, Mulder BJ. Opportunities in pulmonary valve replacement. Expert Rev Cardiovasc Ther 2009;7:1117-22. https://doi.org/10.1586/erc.09.89
  2. Scherptong RW, Hazekamp MG, Mulder BJ, et al. Follow-up after pulmonary valve replacement in adults with tetralogy of Fallot: association between QRS duration and outcome. J Am Coll Cardiol 2010;56:1486-92. https://doi.org/10.1016/j.jacc.2010.04.058
  3. Waien SA, Liu PP, Ross BL, Williams WG, Webb GD, McLaughlin PR. Serial follow-up of adults with repaired tetralogy of Fallot. J Am Coll Cardiol 1992;20:295-300. https://doi.org/10.1016/0735-1097(92)90093-3
  4. Harrild DM, Berul CI, Cecchin F, et al. Pulmonary valve replacement in tetralogy of Fallot: impact on survival and ventricular tachycardia. Circulation 2009;119:445-51. https://doi.org/10.1161/CIRCULATIONAHA.108.775221
  5. Therrien J, Siu SC, Harris L, et al. Impact of pulmonary valve replacement on arrhythmia propensity late after repair of tetralogy of Fallot. Circulation 2001;103:2489-94. https://doi.org/10.1161/01.CIR.103.20.2489
  6. Harrison DA, Harris L, Siu SC, et al. Sustained ventricular tachycardia in adult patients late after repair of tetralogy of Fallot. J Am Coll Cardiol 1997;30:1368-73. https://doi.org/10.1016/S0735-1097(97)00316-1
  7. Sabate Rotes A, Connolly HM, Warnes CA, et al. Ventricular arrhythmia risk stratification in patients with tetralogy of Fallot at the time of pulmonary valve replacement. Circ Arrhythm Electrophysiol 2015;8:110-6. https://doi.org/10.1161/CIRCEP.114.001975