DOI QR코드

DOI QR Code

Design of Naphtha Splitter Unit with Petlyuk Distillation Column Using Aspen HYSYS Simulation

Aspen HYSYS를 이용한 나프타 분리공정의 Petlyuk Distillation Column 설계

  • Lee, Ju-Yeong (Department of Environmental & Chemical Industry, Ulsan College)
  • 이주영 (울산과학대학 환경화학공업과)
  • Received : 2017.11.16
  • Accepted : 2018.02.02
  • Published : 2018.02.28

Abstract

FRN (Full range Naphtha) is distilled from crude oil in a Naphtha Splitter Unit and is separated into the Light Straight Naphtha, Heavy Naphtha, and kerosene according to the boiling point in sequence. This separation is conducted using a series of binary-like columns. In this separation method, the energy consumed in the reboiler is used to separate the heaviest components and most of this energy is discarded as vapor condensation in the overhead cooler. In this study, the first two columns of the separation process are replaced with the Petlyuk column. A structural design was exercised by a stage to stage computation with an ideal tray efficiency in the equilibrium condition. Compared to the performance of a conventional system of 3-column model, the design outcome indicates that the procedure is simple and efficient because the composition of the liquid component in the column tray was designed to be similar to the equilibrium distillation curve. An analysis of the performance of the new process indicated an energy saving of 12.3% under same total number of trays and with a saving of the initial investment cost.

나프타분리공정은 원유에서 증류 공정에 의해 얻어지는 풀레인지납사(Full Range Naphtha)를 원료로 하여 끓는점 차이에 의해 각각 경질납사, 중질납사 및 등유 반제품으로 순차적으로 분리한다. 이러한 전통적인 분리 방법은 2성분을 분리하는 Column을 연속으로 설치하여 생산한다. 이러한 분리방법은 리보일러에서 소비되는 에너지가 증류탑 내부 고비점 성분을 분리시키는 데 사용되고 이 에너지의 대부분은 탑정의 냉각기에서 응축열로 버려지게 때문에 에너지 낭비가 큰 것으로 알려져 있다 본 연구에서는 납사분리공정의 2개의 Column을 Petlyuk Column으로 설계하였다. 탑내 조성분포가 평형관계만으로 계산되는 이상적 단수 효율 하에서 stage to stage 계산방법으로 구조적 설계를 하였고 일반 증류탑과 비교한 결과 제시된 Petlyuk Distillation Column의 설계 방법이 기존의 3-column 모델법보다 설계 시간이 단축될 뿐만 아니라 증류탑내의 액의 조성분포를 평형증류 조성곡선과 유사하도록 설계함으로써 에너지 효율 측면에서도 효율적임을 입증하였다. 또한 같은 tray 단수하에서 Petlyuk Column은 일반 증류탑 대비 약 12.3% 에너지가 절약될 뿐만 아니라 초기 투자비도 절약됨을 알 수 있었다.

Keywords

References

  1. R.Smith, "Chemical process design," pp. 129, McGraw- Hill Book Co., N. Y., 1995.
  2. W.D. Seider, J. D. Seader and D.R. Lewin, "Process design principle," pp. 141, John Wiley & Sons, Inc., N. Y., 1999.
  3. Y. H. Kim, "Structural design of extended fully thermally coupled distillation columns," Ind. Eng. Chem. Res., vol. 40, pp. 2460-2466, 2001. DOI: https://doi.org/10.1021/ie000791d
  4. Y. H. Kim, "Structural design and operation of a fully thermally coupled distillation column," Chem. Eng. J., vol, 85, pp. 289-301, 2002. DOI: https://doi.org/10.1016/S1385-8947(01)00170-X
  5. Kim,Y. H., "An Alternative Structure of a Fully Thermlly Coupled Distillation Column for Improved Operability", J. Chem. Eng., Japan, 36, 1503, 2003. DOI: https://doi.org/10.1252/jcej.36.1503
  6. Widagdo, S., Seider, W. D., "Azeotropic Distillation", AIChe J., vol. 42, no. 1, pp. 96-130, 1996. DOI: https://doi.org/10.1002/aic.690420110
  7. Glinos, K., Malone, M. F., "Optimality Regions for Complex Column Alternatives in Distillation System", Chem. Eng. Res. Des., vol. 66, no. 3, pp. 229, 1988.
  8. Triantafyllou, C., Smith, R.; "The Design and Optimization of Fully Thermally Coupled Distillation Columns," Trans IChemE, 70, part A, pp. 118-132, 1992.
  9. Kim, Y. H., M. Nakaiwa and K. S. Hwang.; "Approximate Design of Fully Thermally Coupled Distillation Columns," Korean J. Chem. Eng., 19, pp. 383-390, 2002. https://doi.org/10.1007/BF02697144
  10. J. D. Seader, E. J. Henley, "Separation process principles," pp. 510, John Wiley & Sons, Inc., N.Y., 1998.