DOI QR코드

DOI QR Code

신축공동주택에서 플러쉬아웃 실시에 따른 실내 VOCs 농도저감 효과에 관한 연구

Reduction of Indoor VOCs' Concentrations using Flush-out in a Newly Built Apartment

  • 투고 : 2018.06.25
  • 심사 : 2018.12.11
  • 발행 : 2018.12.30

초록

The purpose of this study was to confirm the effects of flush-out on the reduction of Volatile Organic Compounds(VOCs) concentration in newly built residential buildings. The field measurements were conducted in two complexes of multi-residential buildings which are located suburban areas of Seoul. About three samples of residential buildings were selected in the field measurements. Two samples, B and C, had been flush-out with outdoor air more than seven days. The sample A was maintained at same condition during the flush-out because of the comparison. The indoor concentrations of VOCs in the three samples were measured at three times, before, during, and after flush-out. From the field measurements, it was confirmed that two samples' indoor VOCs' concentrations were considerably decreased after the flush-out comapred with those of the sample A in which the flush-out was not conducted. The decreases of indoor VOCs concentrations were corresponding to about 50% ~ 92% of the concentrations of before. Through the reviews for the previous studies, it was also found that the reduction effects of the flush-out is similar with the those of the bake-out which were reported in the previous studies.

키워드

과제정보

연구 과제 주관 기관 : 한국연구재단

참고문헌

  1. Kim, K. H., Lee, K. Y., & Park, J. S. (2015). A study on the current status and improvement in performing flush-out in muti-family residential buildings, Korean Journal of The Architectural Institute, 31, 129-134.
  2. Lee, K. Y., Kim K. H., & Park, J. S. (2016). Study of energy cost for performing flush-out in newly constructed multi-residential buildings during winter season, Korean Journal of Air-Conditioning and Refrigeration Engineering, 28, 110-114. https://doi.org/10.6110/KJACR.2016.28.3.110
  3. Yoo, B. H., Park, Y. S., & Cho, H. (2005). Reduction Effect on Chemical Substance in Indoor Air Pollution Using Bake-out, Proceedings of the AIK 2005 Annual Conference, 25, 83-86.
  4. Park, E. Y., Kang, D. H., Choi, D. H., Sung, M. K., Yeo, M. S., & Kim, K. W. (2006). An Experimental Study on Bake-Out of New Apartment Buildings in Summer, Proceeding of the SAREK 2006 Winter Annual Conference, 138-143.
  5. Yoo, B. H. (2007). A Study on Reduction Effect of Chemical Substances on Different Methods of Bake Out in New Apartment in Summer, Korean Journal of The Architectural Institute, Vol. 23, No 9, pp. 163-171.
  6. Park, H. W., Kang, D. H., Lee, G. D., Park, Y. S., Yeo, M. S., & Kim, K. W. (2005). Experimental Study on the Effect of Ventilation on Indoor Air Quality in Baking out, Korean Journal of The Architectural Institute, 25(1), 399-402.
  7. Jo, W. J., & Sohn, J. Y. (2008). The Effect of Bake-out Conditions on Indoor Air Quality, Korean Journal of The Architectural Institute, 24(9), 295-302.
  8. Jung, S. Y., Yoon, C. H., & Park, J. S. (2007). Long term variations of Formaldehyde and VOCs concentrations in an apartment finished by HB Mark Labelling building materials, Journal of Architectural Institute of Korea, 23(7), 277-287.
  9. Kim, C. N., Kim Y. K., & Lee, S. J. (2008). A study on Concentration of Volatile Organic Compounds in Newly-Apartment House by Measurement, Proceeding of the SAREK 2008 Summer Annual Conference, 1220-1224.
  10. Park, D. S., & Sohn, J. Y. (2008). The Effect of Ventilation on VOCs Emission rate during the Bake-out Procedure in Newly Constructed Apartments, Proceeding of the SAREK 2008 Summer Annual Conference, 708-713.
  11. J. R. Girman., L. E. Nevantis., M. X. Petreas., & L. M. Webber. (1990) Building Bake-out Studies, Proc. of indoor Air 90, 3, 349-354 .
  12. Kang, D. H., Choi, D. H., Kim, S. S., Kim, Y. D., Yeo, M. S., & Kim, K. W. (2006). A Prediction of VOCs Emission Rate with Temperature Variation in Floor Heating Space by Numerical Analysis, Korean Journal of Air-Conditioning and Refrigeration Engineering, 18(6), 468-476.
  13. Park, J. S., & Ikeda, L. (2006). Variations of formaldehyde and VOC levels during 3 years in new and older homes, Indoor Air, 16, 129-135. https://doi.org/10.1111/j.1600-0668.2005.00408.x
  14. Korean Institute of Architectural Sustainable Environment and Building Systems. (2013). Building Airtightness Criteria.
  15. Kwon, K. W., Yoon, C. H., & Park, J. S. (2007). Prediction of VOCs Emission Rate from Multi-layers Finishing by using Effective Diffusion Coefficients of Single Materials, Korean Journal of The Architectural Institute, 23, 269-277.