DOI QR코드

DOI QR Code

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis

Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례

  • Kim, Seong-Mo (Department of Dental Prosthodontics, Anam Hospital, Korea University) ;
  • Park, Jin-Hong (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medical Center, Korea University) ;
  • Ryu, Jae-Jun (Department of Dental Prosthodontics, Anam Hospital, Korea University) ;
  • Shin, Sang Wan (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medical Center, Korea University) ;
  • Lee, Jeong-Yol (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medical Center, Korea University)
  • 김성모 (고려대학교 안암병원 치과 보철과) ;
  • 박진홍 (고려대학교 구로병원 임상치의학 연구소) ;
  • 류재준 (고려대학교 안암병원 치과 보철과) ;
  • 신상완 (고려대학교 구로병원 임상치의학 연구소) ;
  • 이정열 (고려대학교 구로병원 임상치의학 연구소)
  • Received : 2017.09.14
  • Accepted : 2017.12.21
  • Published : 2018.04.30

Abstract

The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Cone beam computerized tomography (CBCT)의 발전은 환자의 해부학적 구조를 3차원적으로 분석할 수 있게 하였다. Surgical guide는 CBCT와 CAD/CAM, 임플란트 진단 소프트웨어의 접목을 통해 미래의 보철물을 계획하고 적합한 위치에 임플란트를 식립할 수 있게 한다. Guided surgery를 통해 해부학적 구조물에 대한 침범을 최소한으로 줄일 수 있고 보다 재현성 있는 치료계획의 설정이 가능하다. 본 증례는 전악 무치악 환자에게 surgical guide를 이용하여 다수의 임플란트를 식립한 증례로 수술시간을 단축시킬 수 있었으며 임시 보철물을 미리 제작함으로써 보다 쉽게 immediate loading을 시행할 수 있었다. 환자는 개선된 안모와 저작기능에 만족하였다.

Keywords

References

  1. Misch CE. Contemporary implant dentistry. 3rd ed. St. Louis: Mosby; 2008. p. 17-21, 814-8.
  2. BouSerhal C, Jacobs R, Quirynen M, van Steenberghe D. Imaging technique selection for the preoperative planning of oral implants: a review of the literature. Clin Implant Dent Relat Res 2002;4:156-72. https://doi.org/10.1111/j.1708-8208.2002.tb00167.x
  3. Widmann G, Bale RJ. Accuracy in computer-aided implant surgery-a review. Int J Oral Maxillofac Implants. 2006;21: 305-13.
  4. Abboud M, Wahl G, Guirado JL, Orentlicher G. Application and success of two stereolithographic surgical guide systems for implant placement with immediate loading. Int J Oral Maxillofac Implants 2012;27:634-43.
  5. Hultin M, Svensson KG, Trulsson M. Clinical advantages of computer-guided implant placement: a systematic review. Clin Oral Implants Res 2012;23:124-35. https://doi.org/10.1111/j.1600-0501.2012.02545.x
  6. Raico Gallardo YN, da Silva-Olivio IRT, Mukai E, Morimoto S, Sesma N, Cordaro L. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res 2017;28:602-12. https://doi.org/10.1111/clr.12841
  7. Arisan V, Karabuda CZ, Ozdemir T. Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin Oral Implants Res 2010;21:980-8.
  8. Yong LT, Moy PK. Complications of computer-aided-design/computer-aided-achining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results. Clin Implant Dent Relat Res 2008;10:123-7. https://doi.org/10.1111/j.1708-8208.2007.00082.x
  9. Di Giacomo GA, da Silva JV, da Silva AM, Paschoal GH, Cury PR, Szarf G. Accuracy and complications of computerdesigned selective laser sintering surgical guides for flapless dental implant placement and immediate definitive prosthesis installation. J Periodontol 2012;83:410-9. https://doi.org/10.1902/jop.2011.110115
  10. Schneider D, Marquardt P, Zwahlen M, Jung RE. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clin Oral Implants Res 2009;20:73-86. https://doi.org/10.1111/j.1600-0501.2009.01788.x
  11. D'haese J, Van De Velde T, Komiyama A, Hultin M, De Bruyn H. Accuracy and complications using computerdesigned stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. Clin Implant Dent Relat Res 2012;14:321-35. https://doi.org/10.1111/j.1708-8208.2010.00275.x
  12. Misir AF, Sumer M, Yenisey M, Ergioglu E. Effect of surgical drill guide on heat generated from implant drilling. J Oral Maxillofac Surg 2009;67:2663-8. https://doi.org/10.1016/j.joms.2009.07.056
  13. Aparicio C, Rangert B, Sennerby L. Immediate/early loading of dental implants: a report from the Sociedad Espanola de Implantes World Congress consensus meeting in Barcelona, Spain, 2002. Clin Implant Dent Relat Res 2003;5:57-60.