초록

The purpose of this study is to improve the seismic performance of RC framed buildings such as piloti buildings and school facilities. For this purpose, a half size RC frame specimen (SFD) was made and the inside of frame was reinforced with steel frame and S type strut steel damper. The experimental results are compared with those of the previous studies under the same conditions. The comparative specimens are non-reinforced specimen (BF) and damper reinforced specimen (AFD) that confined the column with an aramid sheet. As a result of comparing the maximum strength, stiffness degradation and energy dissipation capacity, SFD specimen was evaluated to be better than comparative specimens. According to the experimental results and FE analysis results, it was confirmed that the shear deformation was concentrated in the steel damper. And it was showed that cracks were concentrated at the upper and lower ends of the strut of the S type damper, and the final failure was observed at struts. From this, it was verified that the steel damper appropriately dissipates energy due to the lateral load.

키워드

과제정보

연구 과제 주관 기관 : 한국연구재단

참고문헌

  1. Huynh, C.T., Park, K.H., & Kim, J.K. (2010). Seismic Retrofit of Reinforced Concrete Structures Using Steel Braces and Moment Frames, Journal of the Computational Structures Engineering Institute of Korea, 23(5), 509-516.
  2. Hsu, H.L., & Halim, H. (2017). Improving seismic performance of framed structures with steel curved dampers, Engineering Structures, 130, 99-111 https://doi.org/10.1016/j.engstruct.2016.09.063
  3. Marriott, D., Pampanin S., Bull, D., & Palermo, A. (2008). Dynamic testing of precast, post-tensioned rocking wall systems with alternative dissipating solutions, Bulletin of the New Zealand Society of Earthquake Engineering, 41(2), 90-103.
  4. Lee, H.H. (2012). Metallic Damper Strengthening Effect evaluation of RC Frame by FE analysis, Proceeding of the Korea Concrete Institute, 24(2), 239-240.
  5. Lee, H.H. (2015). Capacity Development of Existing Frame by Aramid Sheet and Energy Dissipation Device, Journal of the Korea Institute for Structural Maintenance Inspection, 19(5), 112-119. https://doi.org/10.11112/jksmi.2015.19.5.112
  6. Lee, K.S., Jung, J.S., & Lee, J.K. (2015). Seismic Performance Evaluation of Seismic Strengthening Method using SRCF External Connection of Medium and Low-rise R/C Buildings, Journal of the Korea Concrete Institute, 27(2), 147-155. https://doi.org/10.4334/JKCI.2015.27.2.147
  7. Oh, S.H., Ryu, H.S., & Moon, T.S. (2005). Study for Fabricable and Adhesive Seismic Retrofit Method using the Steel Members, Journal of the Architectural Institute of Korea, Structure & Construction Section, 21(11), 51-58.
  8. Song, W.Y., An, J.H., & Park, C.S. (2011). A Comparative Study on Seismic Retrofit Technique for Seismic Retrofit of Existing Low-Rise Building in University, Journal of the Regional Association of Architectural Institute of Korea, 3(2), 1-8.
  9. Teruna, D.R., Majid, T.A., & Budiono, B. (2015). Experimental Study of Hysteretic Steel Damper for Energy Dissipation Capacity, Advances in Civil Engineering, 2015(631726), 1-12.
  10. Wada, A., Qu, Z., Motoyui, S., & Sakata, H. (2011). Seismic retrofit of existing SRC frames using rocking walls and steel dampers, Frontiers of Architecture and Civil Engineering in China, 5(3), 259-266. https://doi.org/10.1007/s11709-011-0114-x