DOI QR코드

DOI QR Code

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment

고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구

  • 박진호 (한양대학교 건축시스템공학과) ;
  • 장현오 (한국건설생활환경시험연구원 산업융합기술센터) ;
  • 이한승 (한양대학교 건축학부)
  • Received : 2018.03.15
  • Accepted : 2018.06.11
  • Published : 2018.07.01

Abstract

The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.

기존의 정수처리 방법으로는 제거되지 않는 물질이 발생함에 고도정수 처리 시설의 도입이 증가하고 있다. 그러나 오존을 이용한 고도정수처리 시설의 내부 방수 방식재는 오존의 산화력에 의해 열화되며 콘크리트까지 영향을 미쳐 내구성 저하의 원인이 된다. 본 연구에서는 내오존성 및 내화학성이 뛰어난 금속 패널을 기존의 시공법 보다 손쉬운 방법으로 시공하기 위한 방법으로 금속용사 공법을 이용하여 수처리 시설 콘크리트 구조물의 열화를 원천적으로 방지하기 위한 마감공법 개발 연구의 일원으로 용사금속 종류 및 피막의 표면처리 방법에 따른 내오존성 평가를 실시하였으며, 오존처리 후의 부착강도를 평가하였다. 실험결과 용사금속 Ti이 용사 후에도 내오존성이 뛰어난 것으로 나타났으며 표면처리 방법으로는 테프론계 봉공처리제를 사용하여 마감하는 것이 내오존성 및 부착성능 확보에 가장 적합한 방법이라 판단된다.

Keywords

References

  1. Bhalerao, B.B.; Arceivala, S.J. (2016), Application of corrosion control techniques in municipal water and waste water engineering. Available online: http://eprints.nmlindia.org/5825/1/129-139PDF (accessed on9 January 2016).
  2. Choe H,B, Lee H,S, Shin J,H. (2014) Experimental Study on the Electrochemical Anti-Corrosion Properties of Steel Structures Applying the Arc Thermal Metal Spraying Method, Materials, MDPI AG, 7(12), pp7722-7736 https://doi.org/10.3390/ma7127722
  3. Chung, M.J. (2006), A Study on the Evaluation of Field Application for the Waterproofing or Corrosion Proof Construction Method, as Coating High Quality Filtration plant with Ozone Resistance Paints of Phenol Degeneration Polyamine, Master Thesis, Seoul National University of Science and Technology.
  4. Crowe, D.; Nixon, R. (2016), Corrosion of stainless steels in waste water applications. Available online: http://www.hwea.org/wp-content/uploads/2015/07/150204_Corrosion_of_Stainless_Steels_in_Wastewater_Applications.pdf (accessed on 19 January 2016).
  5. Dodo, M.C.; Buffle, M.O.; Ginten, U.V. (2006), Oxidation of antibacterial molecules by aqueous ozone: Moiety-specific reaction kinetics and application to ozone-based wastewater treatment. Environ. Sci. Technol, AMER CHEMICAL SOC, 40(6), 1969-1977. https://doi.org/10.1021/es051369x
  6. Giergiczny, Z.; Krol, A. (2008), Immobilization of heavy metals (Pb, Cu, Cr, Zn, Cd, Mn) in the mineral additions containing concrete composites. J. Hazard. Mater, ELSEVIER SCIENCE BV, 160(2-3), 47-255.
  7. Hirsch, R.; Ternes, T.A.; Haberer, K.; Kratz, K.L. (1999) Occurrence of antibiotics in the environment. Sci. Total Environ, AMER CHEMICAL SOC, 225, 109-118 https://doi.org/10.1016/S0048-9697(98)00337-4
  8. KS K 4716 (2016), Cement Filling Compound for Surface Preparation, Korean Agency for Technology and Standards (KATS): Seoul, Korea.
  9. Lai, J.K.L. (1983), A review of precipitation behaviour in AISI type 316 stainless steel. Mater. Sci. Eng, ELSEVIER SCIENCE SA LAUSANNE, 61(2), 101-109. https://doi.org/10.1016/0025-5416(83)90191-X
  10. Lee, H.S.; Park, J.H.; Singh, J.K.; Ismail, M.A. (2016) Protection of reinforced concrete structures of waste water treatment reservoirs with stainless steel coating using arc thermal spraying technique in acidified water. Materials, MDPI, 9(9), 753. https://doi.org/10.3390/ma9090753
  11. SPS KWWA M211 (2015), Ozone Resistance Test Method of Material for Waterproof and Anticorrosion, Korea Water and WastewaterWorks Association (KWWA), Seoul, Korea.