DOI QR코드

DOI QR Code

3차원 수직·수평 건축공간분석을 위한 ERAM모델의 보행에너지 가중치 산정 연구

The Method to Calculate the Walking Energy-Weight in ERAM Model to Analyze the 3D Vertical and Horizontal Spaces in a Building

  • 투고 : 2017.09.11
  • 심사 : 2018.03.13
  • 발행 : 2018.06.30

초록

The aim of this study is to propose a method for calculating the weight of walking energy in ERAM model by calculating it for the analysis of vertical and horizontal spaces in a building. Conventional theories on the space analysis in the field of architectural planning predict the pedestrian volume of network spaces in urban street or in two-dimensional plane within a building, however, for vertical and horizontal spaces in a building, estimates of the pedestrian volume by those theories are limited. Because in the spatial syntax and ERAM model have been applied weights such as the spatial depth, adjacent angles, and physical distances available only to the two-dimensional same layer or plane. Therefore, the following basic assumptions and analysis conditions in this study were established for deriving a predictor of pedestrian volume in vertical and horizontal spaces of a building. The basic premise of space analysis is not to address the relationship between the pedestrian volume and the spatial structure itself but to the properties of spatial structure connection that human beings experience. The analysis conditions in three-dimensional spaces are as follows : 1) Measurement units should be standardized on the same scale, and 2) The connection characteristics between spaces should influence the accessibility of human beings. In this regard, a factor of walking energy has the attributes to analyze the connection of vertical and horizontal spaces and satisfies the analysis conditions presented in this study. This study has two implications. First, this study has shown how to quantitatively calculate the walking energy after a factor of walking energy was derived to predict the pedestrian volume in vertical and horizontal spaces. Second, the method of calculating the walking energy can be applied to the weights of the ERAM model, which provided the theoretical basis for future studies to predict the pedestrian volume of vertical and horizontal spaces in a building.

키워드

참고문헌

  1. Pandolf, K. B., Givoni, B. & Goldman, R. F. (1976). Predicting Energy Expenditure with Loads While Standing or Walking very slowly, US Army Research Institute of Environmental Medicine, Natick, Masschusetts, 578.
  2. Choi, J., Cho, H. & Choi, H. (2005). ERAM Model : The Estimation of Space Usage in Tall and Huge-Scale buildings, Proceedings of the 5th International Symposium on Space Syntax.
  3. Hillier, B., Leaman, A., Stansall, P. & Bedford, M. (1976). Space Syntax, Environment and Planning B, 3(2), 147-185. https://doi.org/10.1068/b030147
  4. Turner, A. (2001). Angular Analysis, Proceedings of the 3td International Symposium on Space Syntax.
  5. Cho, H. (2005). Angular-Weighted ERAM Model for Space Analysis, Ph.D. Dissertation, Seoul National University.
  6. Steadman, P. (2004). Development in Space Syntax, Environment and Planning B, 20(4).
  7. Park, G. (2013). Development of Analysis Scale of Space Depth Trough Considered Both Length and Connection Angle of Aisle of Aisle to Estimate Traffic Volume within the Space, Journal of Architectural Institute of Korea, 29(9), 51-58.
  8. Park, S., Lee, J., Kang, D., Jung, E., Jeon, H. & Park, S. (2007). A study on Walking Velocity and Walking distance b y Age, Journal of Eromonomics Society of Korea, 430-434.
  9. Choi, J., Jeon, E., Hong, W. & Ryou, H. (2009). Calculation of Revision Coefficient of Evacuee's Walking Speed of Op erate an Evacuation Simulator aiming at a High-rise buildings, Journal of Architectural Institute of Korea, 29(1), 649-652.