Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test

비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가

  • Received : 2019.08.06
  • Accepted : 2019.10.11
  • Published : 2019.10.30

Abstract

In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. KDS (2019). Seismic Design Code of Buildings (KDS 41 17 00: 2019), Korean Design Standard
  2. Sato Y., Motoyui S., MacRae G. A., & Dhakal R. P. (2011). Ceiling Fragility of Japanese Ceiling Systems, Proceedings of the Ninth Pacific Conference on Earthquake Engineering, Auckland, New Zealand
  3. Dhakal R. P., MacRae G. A., Pourali A., & Paganotti G. (2016). Seismic fragility of suspended ceiling systems used in NZ based on component tests, Bulletin of the New Zealand Society for Earthquake Engineering, 49(1), 45-63 https://doi.org/10.5459/bnzsee.49.1.45-63
  4. Gilani A. S. J., Takhirov S. M., & Straight Y. (2017). Evaluation of seismic performance of suspended ceiling systems using dynamic testing and finite element analysis, 16th World Conference on Earthquake, 16WCEE, Paper No. 1289
  5. Gilani A. S. J., Takhirov S. M., & Tedesco L. M. (2014). Proposed New approach for the seismic evaluation testing of suspended ceiling systems, 10th U.S. National Conference on Earthquake Engineering, 10NCEE, Anchorage, Alaska
  6. Pourali A., Dhakal R. P., & MacRae G. A. (2015). Shake table tests of perimeter-fixed type suspended ceilings, New Zealand Society for Earthquake Engineering, 2015NZSEE Conference
  7. Ozcelik O., Misir I. S. & Saridogan S. (2016). Performance evaluation of suspended ceiling systems using shake table test, Structural Engineering & Mechanics, 58(1), 121-142 https://doi.org/10.12989/sem.2016.58.1.121
  8. Soroushian S., Ryan K. L., Maragakis M., Wieser J., Sasaki T., Sato E., Okazaki T., Tedesco L., Zaghi A. E., Mosqueda G., & Alvarez D. (2012). NEESE-Defense Tests, Seismic Performance of Ceiling, Sprinkler Piping Nonstructural Systems in Base Isolated and Fixed Base Building, 15th World Conference on Earthquake, 15WCEE
  9. Magliulo G., Pentangelo V., Maddaloni G., Capozzi V., Petrone C., Lopez P., Talamonti R., & Manfredi G. (2012). Shake Table Test for Seismic Assessment of Suspended Continuous Ceilings, Bulletin of Earthquake Engineering, 10(6), 1819-1832 https://doi.org/10.1007/s10518-012-9383-6
  10. Lee, J., In, S., Jung, D., Lee, S., & Cho, B. (2019). Shaking-Table Evaluation of Seismic Performance of Suspended Steel-Panel Ceiling, 4th International Workshop on the Seismic Performance of Non-Structural Elements
  11. ICC Evaluation Service, LLC (ICC-ES) (2010). ICC-ES AC156, Acceptance criteria for seismic certification by shake-table testing of non-structural components and systems, International Code Council, Whittier, CA.
  12. American Society of Civil Engineers (ASCE) (2016), ASCE/SEI 7-16: Minimum Design Loads for Buildings and Other Structures, ASCE, Reston, VA, US.