Abstract

The seismic reinforcement ratio of SOC facilities, such as domestic roads and railroads, is 96%. Out of approximately 7 million buildings as of 2016, only 0.51 million buildings with seismic performance were secured. Although the proportion of masonry structures is 38.8% of the total buildings, there is almost no seismic resistance, only 2.0%. To solve the problem in Korea, government-level seismic measures are being promoted, but the situation is insufficient. Overseas, the UBC research team in Vancouver, Canada, has developed and used EDCC to reinforce the seismic performance of masonry buildings. EDCC is a construction material that can secure concrete ductility capability by mixing fibers and secure deformation resistance of concrete through bridging action. It is necessary to examine various materials because EDCC is not used as a spray type of secure seismic reinforcement. In this study, as part of the research and development of spraying materials to improve the durability of masonry buildings, this study examined the spraying characteristics of fiber-reinforced mortar according to fiber use and the viscosity change according to the use of thickener. As a result, the working performance of the fiber-reinforced mortar for seismic reinforcement was improved when using 1% fiber and 1% thickener.

국내 도로, 철도 등 SOC 시설의 내진보강율은 2017년 기준 96%이며 건축물은 2016년 기준 약 7백만동 중 내진성능이 확보된 건축물은 51만동에 불과하다. 조적조 건축물은 전체 건축물의 38.8%를 차지할 만큼 비중이 크지만 내진성능이 확보된 것은 2.0% 내외로 거의 전무한 실정이다. 이러한 문제를 해결 하기 위해국내에서는 정부차원의 내진 대책이 추진되고 있으나 현재까지 미비한 상황이다. 국외의 캐나다 벤쿠버 UBC 연구팀은 조적조 내진성능 보강을 위해 EDCC를 개발하여 사용하고 있다. EDCC는 섬유혼입으로 콘크리트 연성능력 확보 및 가교작용으로 콘크리트의 변형 저항능력을 확보 할 수 있는 건설재료이다. 그러나 내진성능 확보를 위해 EDCC를 분사형으로 사용하지 않기 때문에 다양한 재료의 검토가 필요하다. 이에 본 연구에서는 조적조의 내구성능 향상을 위한 뿜칠재료 연구개발의 일환으로 내진보강용 섬유보강 모르타르의 분사특성을 평가하고자 하였으며, 섬유보강 모르타르의 섬유사용량에 따른 분사특성 및 증점제 사용량에 따른 점도변화를 검토하였다. 조적조 내진보강용 섬유보강 모르타르의 부착성능 및 시공성능을 검토한 결과 섬유의 사용량은 1%, 증점제의 사용량은 1%로 최적 사용량을 도출할 수 있었다.

Keywords

References

  1. K. I. Kim, B. G. Lee, J. S. Jung, K. S. Lee, "Seismic Performance Evaluation of Full-size Two-story R/C FrameStrengthened with Concrete Wingwall with Embedded Kagome Trussby Pseudo-dynamic Test", Journal of the Korea Concrete Institute, Vol. 32, No. 2, pp. 173-183, April, 2020 DOI: https://doi.org/10.4334/JKCI.2020.32.2.173
  2. Y. Yan, J. H. Ch, Ch. S. Ch, H. H. Lee, H. Y. Jeon, "Manufacture and Engineering Evaluation of Hybrid Grid Fabrics forSeismic Reinforced Carbon Fiber Composite Yarns. I. Manufacture ofCarbon Fiber Composite Yarn and Fabric Design ", Journal of the The Korean Fiber Society, Vol. 55, No. 4, pp. 280-285, August, 2018 DOI: https://doi.org/10.12772/TSE.2018.55.280
  3. H. Lee, Y. W. Kwon, H. D. Kim, "The Study of Reinforcement through the Nonlinear Static Analysis andInelastic Seismic Performance Evaluation in School Building ", Journal of the Korean Association for Spatial Structures, Vol. 12, No. 2 , pp.55-63, Jun, 2012 https://doi.org/10.9712/KASS.2012.12.2.055
  4. J. S. Kim, J. H. Lim, M. H. Kwon, H. S. Seo, "Analytical Study on the Determination of Shape for Connector ofSeismic Reinforced Strip", J. Korean Soc. Adv. Comp. Struc. Vol. 4, No. 3, pp. 1-6, September, 2013 DOI: http://dx.doi.org/10.11004/kosacs.2013.4.3.001
  5. Y. Ch. Lee, Ch. M. Jung, E. J. Lee, M. H. Kim, K. B. Ch, "Seismic Performance Evaluation of Nonseismic Neighborhood Living FacilitiesConsidering Deterioration", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 17, No. 1, pp.055-063, January, 2013, DOI: http://dx.doi.org/10.11112/jksmi.2013.17.1.055
  6. Lou Corpuz-Bosshart, UBC researchers develop earthquake-resistant concrete, UBC Public Affairs, 2017, https://news.ubc.ca/2017/10/10/ubc-researchers-develop-earthquake-resistant-concrete-2/#contact-box[10]
  7. J. J. Tai, I. G. Moon, Y. K. Lee, "A Study on the Strength Characteristics and Rebound Ratio withRespect to Injection Pressure of Shotcrete", Journal of the Korean Society of Civil Engineers, Vol. 39, No. 1, pp.115-122, February, 2019, DOI: https://doi.org/10.12652/Ksce.2019.39.1.0115
  8. D. S. Jung, G. M. Kim, B. W. Kim, W. S. Kim, Y. K. Kwak, "Study of the Mechanical Properties of Fiber Reinforced ConcreteAccording to Inorganic Fiber Combination", J. Korean Soc. Adv. Comp. Struc. Vol. 11, No. 3, pp. 16-24, June, 2020 DOI: https://doi.org/10.11004/kosacs.2020.11.3.016
  9. B. K. Chun, J. J. Kim, S. H. Kim, D. Y. Yoo, "Correlation between Pullout and Tensile Behaviors of Ultra High Performance Fiber Reinforced Concrete, "Proceedings of the Korea Concrete Institute, Vol. 30, No. 2, pp.661-662, November, 2018.
  10. J. S. Yoo, D. S. Kim, O. S. K, "Comparative Study on Physical Properties and Characteristics of Fiber Reinforced Shotcrete, Korean Society of Civil Engineers, Vol. 1, No. 1, pp.3107-311, November, 2002.