DOI QR코드

DOI QR Code

Indoor Air Quality Index for School Classrooms Based on Health Effects

학교 교실 공기질 관리를 위한 건강영향 기반 실내공기질지수 개발

  • Kim, Do Yun (Department of Applied Environmental Science, Kyung Hee University) ;
  • Kwon, Ji You (Department of Applied Environmental Science, Kyung Hee University) ;
  • Lee, Tae Jung (Department of Applied Environmental Science, Kyung Hee University) ;
  • Park, Young Koo (Department of Earth and Environmental Engineering, Kangwon National University) ;
  • Jo, Young Min (Department of Applied Environmental Science, Kyung Hee University)
  • 김도윤 (경희대학교 환경응용과학과) ;
  • 권지유 (경희대학교 환경응용과학과) ;
  • 이태정 (경희대학교 환경응용과학과) ;
  • 박영구 (강원대학교 지구환경시스템공학과) ;
  • 조영민 (경희대학교 환경응용과학과)
  • Received : 2021.11.08
  • Accepted : 2021.12.03
  • Published : 2021.12.31

Abstract

An indoor air quality index for school classrooms based on the Hazard Quotient (HQ) was developed in this study. The current index (IAQI-S) covered PM10, PM2.5, and CO2, and breakpoints of IAQI-S were calculated using each HQ value. IAQI-S was applied to the real-time data obtained from 123 classrooms of 46 schools during November 2017 to December 2020. As a result of the comprehensive assessment, 93.1% of PM10 and 94% of PM2.5 belonged to 'good' and 'moderate', respectively. The IAQI-S based on an 8-hour predicted moving average was compared with Comprehensive Air-quality Index (CAI) and with the IAQI of a foreign reference. The IAQI-S includes CO2 and consists of more stringent levels comparing to outdoor index (CAI).

어린 학생들에 대한 HQ (Hazard Quotient) 기반으로 학교교실 실내 공기질 지수 (IAQI-S)를 개발하였다. IAQI-S는 PM10, PM2.5, CO2를 포함하며, IAQI-S의 기준농도는 지정된 HQ값을 통해 산출하였다. 본 연구에서 개발한 IAQI-S를 이용하여 2017년 11월부터 2020년 12월까지 실시간으로 측정한 전국 46개 학교 123개 학급을 평가해보았다. 종합지수 평가 결과, PM10의 93.1%, PM2.5의 94%가 '좋음'과 '보통' 등급에 포함되었다. 8시간 예측 이동 평균을 기반으로 한 IAQI-S는 CAI(Comprehensive Air-quality Index) 및 외국에서 발표되었던 IAQI와 비교하였다. IAQI-S는 CO2를 포함하며 대기질지수 (CAI)에 비해 더 엄격한 수준으로 구성되어 있음을 알 수 있었다.

Keywords

Acknowledgement

이 성과는 정부(과학기술정보통신부, 교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임(No. 2019M3E7A1113077).

References

  1. American Conference of Governmental Industrial Hygienists (ACGIH). 2019. TLVs® and BEIs®. 19. Available at https://riesgosygestion.com/wp-content/uploads/2019/06/tlv2019_entire-book.pdf.
  2. Brauer M, Amann M, Burnett R, Cohen A, Dentener F, Ezzati M, Henderson S, Krzyzanowski M, Martin R, Van Dingenen R, Van Donkelaar A, Thurston G. 2012. Exposure assessment for estimation of the global burden of disease attributable to outdoor air pollution. Environmental Science Technology 46: 652-660. https://doi.org/10.1021/es2025752.
  3. Choe Y, Heo J, Park J, Kim E, Ryu H, Kim D, Cho M, Lee C, Lee J, Yang W. 2020. Evaluation of Carbon Dioxide Concentrations and Ventilation Rates in Elementary, Middle, and High Schools. Journal of Environmental Health Sciences 46(3): 344-352. https://doi.org/10.5668/JEHS.2020.46.3.344. [Korean Literature]
  4. Department of Occupational Safety and Health in Malaysia (DOSH). 2010. Industry code of practice on indoor air quality. 11. Available at https://www.dosh.gov.my/index.php/legislation/codes-of-practice/chemicalmanagement/594-02-industry-code-ofpractice-on-indoor-air-quality-2010/file.
  5. Du Z, Mo J, Zhang Y. 2014. Risk assessment of population inhalation exposure to volatile organic compounds and carbonyls in urban China. Environment International 73: 33-45. https://doi.org/10.1016/j.envint.2014.06.014.
  6. Health and Safety Executive in U.K. (HSE). 2005. EH40 Workplace exposure limits. 11. Available at https://www.hse.gov.uk/pubns/books/eh40.htm.
  7. Heo S, Kwon J, Lee S, Kim D, Lee T, Jo Y. 2021. Spatial Concentration of Carbon Components in Indoor PM2.5 of School Classrooms in a Large City of Korea. Applied Sciences 11(6): 7328. https://doi.org/10.3390/app11167328.
  8. Institute of Environmental Epidemiology Ministry of the Environment in Singapore (SIAQG). 1996. Guidelines for Good Indoor Air Quality in Office Premises. 40-44. Available at https://www.bca.gov.sg/greenmark/others/NEA_Office_IAQ_Guidelines.pdf.
  9. Jeon BI, Kwak MJ, Kang SH, Kim JC, Yun HJ, Kim HH. 2020. Development of IAQ Index for Indoor Air Quality in City Buses. Korean Society of Environmental Health 46(4): 444-456. https://doi.org/10.5668/JEHS.2020.46.4.444. [Korean Literature]
  10. Kim HH, Lim YW, Lee CS, Kim TH, Park JH, Jeon JM, Shin DC, Yang JY. 2011. Health risk assessment of VOCs in the activities space of children: Focused on elementaryschools and academies. Journal of the Korean Society for Indoor Environment 8(4): 263-274. https://ir.ymlib.yonsei.ac.kr/handle/22282913/94987. [Korean Literature]
  11. Kim HH, Yang JY, Lee CS, Kim SD, Yang SH, Shin DC, Lim YW. 2010. Health Risk and Exposure Assessment of Aldehydes in Children's Facilities. Journal of the Korean Society for Indoor Environment 7(2): 89-100. https://ir.ymlib.yonsei.ac.kr/handle/22282913/102241. [Korean Literature]
  12. Lahrz T, Bischof W, Sagunski H. 2008. Gesundheitliche Bewertung von Kohlendioxid in der Innenraumluft. Bundesgesundheitsbl - Gesundheitsforsch - Gesundheitsschutz, 51; 1358-1369. https://doi.org/10.1007/s00103-008-0707-2.
  13. Landrigan P. 1998. Environmental hazards for children in USA. International Journal of Occupational Medicine and Environmental Health 11(2): 189-194.
  14. Lee JH, An SM, Kwak MJ, Kim KJ, Kim HH. 2018. Development of an IAQ Index for Indoor Garden Based IoT Applications for Residents' Health Management. Korean Society of Environmental Health 44(5): 421-432. https://doi.org/10.5668/JEHS.2018.44.5.421. [Korean Literature]
  15. Lim WC. 2015. Literature Review of the Effect of the Carbon Dioxide Concentration in Classroom Air on the Students' Learning Performance. Journal of Environmental Education 28(2): 134-145. http://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE06387039. [Korean Literature]
  16. Meteorological Agency. 2020. Change in annual CO2 concentration. Available at https://www.index.go.kr/potal/stts/idxMain/selectPoSttsIdxMainPrint.do?idx_cd=1399&board_cd=INDX_001.
  17. Ministry of Education. 2020. Education Basic Statistics. Available at https://kess.kedi.re.kr/post/6706365?#. [Korean Literature]
  18. Ministry of Health and Welfare (MHW). 2020. Daycare Center Operation Guide. Available at http://www.mohw.go.kr/upload/content_data/2020/guide_08_03.pdf.
  19. Myhrvold AN, Olsen E, Lauridsen O. 1996. Indoor performance in schools - pupils' health and performance in regard to CO2 concentrations. Indoor Air, 4; 369-374. Available at http://www.aretas.ca/sites/default/files/imce_images/Indoor%20Environment%20in%20Schools%20%E2%80%93%20Pupils%20Health%20%26%20Performance%20in%20Regard%20to%20CO2%20Concentrations.pdf.
  20. National Institute of Environmental Research (NIER). 2019. Korean Exposure Factors Handbook for Children. Available at https://ecolibrary.me.go.kr/nier/#/search/detail/5686029.
  21. Occupational Safety and Health Administration (OSHA). 2019. Permissible Exposure Limits - Annotated Tables. Available at https://www.osha.gov/annotated-pels.
  22. Oh GS, Jung GJ, Im YB. 2010. Impact of Indoor CO2 Concentration on Work Performance. Journal of the Architectural Institute of Korea Planning & Design 30(1): 385-386. http://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01830039. [Korean Literature]
  23. Pukelsheim F. 1994. The three sigma rule. The American Statistician 48(2): 88-91. https://doi.org/10.2307/2684253
  24. Saad SM, Shakaff AYM, Saad ARM, Yusof AM, Andrew AM, Zakaria A, Adom AH. 2017. Develpment of Indoor Environmental Index, Air Quality Index and Thermal Comfort Index. 11th Asian Conference on Chemical Sensors, AIP Conference Proceedings, 1808; 1-11. https://doi.org/10.1063/?1.4975276.
  25. Sacks JD, Stanek LW, Luben TJ, Johns DO, Buckley BJ, Brown JS, Ross M. 2011. Particulate matter - induced health effects: who is susceptible?. Environmental Health Perspective 119: 446-454. https://doi.org/10.1289/ehp.1002255.
  26. Shendell D, Prill R, Fisk W, Apte M, Blake D, Faulkner D. 2004. Associations between classroom CO2 concentrations and student attendance in Washington and Idaho. Indoor Air 14(5): 333-341. https://doi.org/10.1111/j.1600-0668.2004.00251.x.
  27. Son SW, Gil MS, Moon YS. 2016. Exponential Moving Average and 3-Sigma Techniques for Anomaly Detection of Log Data. The Korean Institute of Information Scientists and Engineers 6: 181-183. http://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07018150. [Korean Literature]
  28. The National Institute for Occupational Safety and Health (NIOSH). 2019. NIOSH Pocket Guide to Chemical Hazards. Available at https://www.cdc.gov/niosh/npg/npgd0103.html.
  29. Twardella D, Matzen W, Lahrz T, Burghardt R, Spegel H, Hendrowarsito L, Frenzel A, Fromme H. 2012. Effect of classroom air quality on students' concentration: results of a cluster-randomized cross-over experimental study. Indoor Air 22: 378-387. https://doi.org/10.1111/j.1600-0668.2012.00774.x.
  30. U.S. Environmental Protection Agency (US EPA). 2005. Human Health Risk Assessment Protocol, Chapter 7: Characterizing Risk and Hazard. 7-6. Available at https://archive.epa.gov/epawaste/hazard/tsd/td/web/pdf/05hhrap7.pdf.
  31. U.S. Environmental Protection Agency (US EPA). 2011. Exposure Factors Handbook: 2011 Edition, Chapter 1. 3-4. Available at https://ofmpub.epa.gov/eims/eimscomm.getfile?p_download_id=522996.
  32. U.S. Environmental Protection Agency (US EPA). 2006. 40 CFR Part 50 - National Ambient Air Quality Standards for Particulate Matter; Final Rule. 8-11. Available at https://www.govinfo.gov/content/pkg/CFR-2019-title 40-vol2/pdf/CFR-2019-title40-vol2-part50.pdf.
  33. U.S. Environmental Protection Agency (US EPA). 2020. Facilities Manual Volume 2: Architecture and Engineering Guidelines, Chapter 7. 6-7. Available at https://www.epa.gov/sites/production/files/2018-03/documents/ae_guidelines_508.pdf.
  34. Wang H, Tseng C, Hsieh T. 2008. Developing an indoor air quality index system based on the health risk assessment. Indoor Air, 17-22. Available at https://www.isiaq.org/docs/papers/749.pdf.
  35. World Health Organization (WHO). 2010. WHO Guidelines for indoor air quality - selected pollutants. 4. Available at https://www.euro.who.int/__data/assets/pdf_file/0009/128169/e94535.pdf.
  36. World Health Organization (WHO). 2005. Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide - Global update 2005. Available at https://apps.who.int/iris/bitstream/handle/10665/107823/9789289021920-eng.pdf?sequence=1&isAllowed=y.
  37. Wu J, Weng J, Xia B, Zhao Y, Song Q. 2021. The Synergistic Effect of PM2.5 and CO2 Concentrations on Occupant Satisfaction and Work Productivity in a Meeting Room. International Journal of Environmental Research and Public Health 18: 4109. Available at https://doi.org/10.3390/ijerph18084109.
  38. Yang WH. 2019. Changes in Air Pollutant Concentrations Due to Climate Change and the Health Effect of Exposure to Particulate Matter. Health and Welfare Forum, Korea Institute for Health and Social Affairs, 269; 20-31. Available at http://repository.kihasa.re.kr/handle/201002/31750. [Korean Literature]
  39. Yang WH, Lee KY, Yoon CS, Yu SD, Park KH, Choi WH. 2011. Determinants of residential indoor and transportation activity times in Korea. Journal of Exposure Science and Environmental Epidemiology 21: 310-316. https://doi.org/10.1038/jes.2010.23.
  40. Yoo HJ, Kim JK, Shin JW, Kim YJ, Min SG, Jegal DS, Bang KI, Lee SM. 2017. Health Vulnerability Assessment for PM10 due to Climate Change in Incheon. Journal of Environmental Health Sciences 43(3): 240-246. https://doi.org/10.5668/JEHS.2017.43.3.240. [Korean Literature]
  41. Zhu C, Li N. 2017. Study on indoor air quality evaluation index based on comfort evaluation experiment. Procedia Engineering 205: 2246-2253. https://doi.org/10.1016/j.proeng.2017.10.066.