The fire safety performance of sandwich panels currently in use is non-conforming occasionally. In principle, the non-conforming sandwich panels installed at construction sites should be replaced with conforming ones. However, at the construction sites, instead of replacing the non-conforming sandwich panels, they are reinforcing them with several reinforcement methods in order to enhancing the fire safety performance. Typical reinforcement methods are paint reinforcement, glass wool panel reinforcement, and gypsum board reinforcement. In this study, the fire safety performance of these three reinforcement methods was evaluated using Cone calorimeter test and Single Burning Item Test. As the result, the Cone calorimeter test showed a good value only for the gypsum board reinforcement, and the Single Burning Item Test showed a good value for the glass wool panel reinforcement and the gypsum board reinforcement.

키워드

참고문헌

  1. An, H. J., Choi, D. H., Shin, B. J., Lee, G. H., & Cho, H. S. (2019). survey of the current state of the ceramic (fireproof building material) main material (sandwich panel) industry, Korea Institute for Advancement of Technology, 7
  2. Babrauskas. V., & Peacock. R. D (1992). Heat Release Rate : The Single Most Important Variable in Fire Hazard, Fire Safety J. 18, 255-272 https://doi.org/10.1016/0379-7112(92)90019-9
  3. Chemical Market Research Inc (2017). Analysis and outlook of the domestic building materials market, Multi client Report, 7-9
  4. Cho, K. S., Chae, S. U., Choi, J. H., & Kim, H. Y. (2017). A Study on Comparison Test for Application of a Full-Scale Fire Spread Test Method of External Cladding System of Building, J. Korean Soc. Hazard Mitig. Vol. 17, No. 3 (Jun. 2017), 1-10 https://doi.org/10.9798/KOSHAM.2017.17.3.1
  5. Korean Agency for Technology and Standards (2018). KS F ISO 5660-1, Reaction to fire test - Heat release. smoke production and mass loss rate - Part 1 : Heat release rate(Cone calorimeter method)
  6. Kwon, I. G. (2019). Monitoring of architecture safety (Architecture materials field), Ministry of Land, Infrastructure and Transport, 139-151
  7. Ministry of Land, Infrastructure and Transport (2020). Flame retardant performance of building finishing materials and fire spread prevention structural standards (No. 2020-263)
  8. Park, K. W., Im, H. S., Jeong, J. G., & Kim, W. H. (2009). Analysis on the Reaction-to-fire's Performance of Sandwich Panel Systems by using ISO 5660-1 and EN 13823 Fire Tests, FIRE SCIENCE AND ENGINEERING 23(1), 2009.2, 33-39
  9. P. Johansson, & P. Hees (2000). Development of a Test Procedure for Sandwich Panels using ISO 9705 Philosophy, SP REPORT