DOI QR코드

DOI QR Code

Delayed Analysis of Hydrogen-Methane Breath Samples

  • Received : 2021.08.28
  • Accepted : 2021.12.17
  • Published : 2022.01.15

Abstract

Purpose: Hydrogen-methane breath tests are used to diagnose carbohydrate malabsorption and small intestinal bacterial overgrowth. The COVID-19 pandemic has driven the modification of procedures as breath tests are potentially aerosol-generating procedures. We assessed the effect of delayed analysis of breath samples, facilitating the at-home performance of breath testing. Methods: Children provided two breath samples at every step of the lactose breath test. The samples were brought back to the clinic, and one set of samples was analyzed immediately. The second set was stored at room temperature and analyzed 1-4 days later. Results: Out of the 73 "double" lactose breath tests performed at home, 33 (45.8%) were positive. The second samples were analyzed 20 to 117 hours after the first samples (41.7±24.3 hours). There was no significant difference in the hydrogen concentration between the first and second sets (Z=0.49, p=0.62). This was not the case for methane, which had a significantly higher concentration in the second breath samples (Z=7.6). Conclusion: Expired hydrogen levels remain stable in plastic syringes if preserved at room temperature for several days. On the other hand, the delayed analysis of methane appeared to be less reliable. Further research is needed to examine the impact of delayed analysis on methane and hydrogen concentrations.

Keywords

References

  1. Levitt MD. Production and excretion of hydrogen gas in man. N Engl J Med 1969;281:122-7. https://doi.org/10.1056/NEJM196907172810303
  2. Klompas M, Baker M, Rhee C. What is an aerosol-generating procedure? JAMA Surg 2021;156:113-4. https://doi.org/10.1001/jamasurg.2020.6643
  3. Gasbarrini A, Corazza GR, Gasbarrini G, Montalto M, Di Stefano M, Basilisco G, et al. Methodology and indications of H2-breath testing in gastrointestinal diseases: the Rome consensus conference. Aliment Pharmacol Ther 2009;29 Suppl 1:1-49.
  4. Rezaie A, Buresi M, Lembo A, Lin H, McCallum R, Rao S, et al. Hydrogen and methane-based breath testing in gastrointestinal disorders: the North American Consensus. Am J Gastroenterol 2017;112:775-84. https://doi.org/10.1038/ajg.2017.46
  5. Hammer HF, Fox MR, Keller J, Salvatore S, Basilisco G, Hammer J, et al.; European H2-CH4-breath test group. European guideline on indications, performance, and clinical impact of hydrogen and methane breath tests in adult and pediatric patients: European Association for Gastroenterology, Endoscopy and Nutrition, European Society of Neurogastroenterology and Motility, and European Society for Paediatric Gastroenterology Hepatology and Nutrition consensus. United European Gastroenterol J 2021. doi: 10.1002/ueg2.12133. [Epub ahead of print].
  6. Vandenplas Y. Lactose intolerance. Asia Pac J Clin Nutr 2015;24 Suppl 1:S9-13.
  7. Eisenmann A, Amann A, Said M, Datta B, Ledochowski M. Implementation and interpretation of hydrogen breath tests. J Breath Res 2008;2:046002. https://doi.org/10.1088/1752-7155/2/4/046002
  8. Solomons NW, Hamilton LH, Christman NT, Rothman D. Evaluation of a rapid breath hydrogen analyzer for clinical studies of carbohydrate absorption. Dig Dis Sci 1983;28:397-404. https://doi.org/10.1007/BF02430527
  9. Niu HC, Schoeller DA, Klein PD. Improved gas chromatographic quantitation of breath hydrogen by normalization to respiratory carbon dioxide. J Lab Clin Med 1979;94:755-63.
  10. Newcomer AD, McGill DB, Thomas PJ, Hofmann AF. Prospective comparison of indirect methods for detecting lactase deficiency. N Engl J Med 1975;293:1232-6. https://doi.org/10.1056/NEJM197512112932405
  11. Solomons NW, Viteri FE, Hamilton LH. Application of a simple gas chromatographic technique for measuring breath hydrogen. J Lab Clin Med 1977;90:856-62.
  12. Jensen WE, O'Donnell RT, Rosenberg IH, Karlin DA, Jones RD. Gaseous contaminants in sterilized evacuated blood collection tubes. Clin Chem 1982;28:1406.
  13. Perman JA, Barr RG, Watkins JB. Sucrose malabsorption in children: noninvasive diagnosis by interval breath hydrogen determination. J Pediatr 1978;93:17-22. https://doi.org/10.1016/S0022-3476(78)80592-7
  14. Rosado JL, Solomons NW. Storage of hydrogen breath-test samples in plastic syringes. Clin Chem 1983;29:583-4. https://doi.org/10.1093/clinchem/29.3.583
  15. Ellis CJ, Kneip JM, Levitt MD. Storage of breath samples for H2 analyses. Gastroenterology 1988;94:822-4. https://doi.org/10.1016/0016-5085(88)90260-0
  16. Corazza GR, Sorge M, Maurino E, Strocchi A, Lattanzi MC, Gasbarrini G. Methodology of the H2 breath test. I. Collection and storage for gas measurement. Ital J Gastroenterol 1990;22:200-4.
  17. Hammer K, Hasanagic H, Memaran N, Huber WD, Hammer J. Relevance of methane and carbon dioxide evaluation in breath tests for carbohydrate malabsorption in a paediatric cohort. J Pediatr Gastroenterol Nutr 2021;72:e71-7. https://doi.org/10.1097/MPG.0000000000003004
  18. Ghoshal UC, Srivastava D, Misra A. A randomized double-blind placebo-controlled trial showing rifaximin to improve constipation by reducing methane production and accelerating colon transit: a pilot study. Indian J Gastroenterol 2018;37:416-23. https://doi.org/10.1007/s12664-018-0901-6
  19. Wolin MJ. Fermentation in the rumen and human large intestine. Science 1981;213:1463-8. https://doi.org/10.1126/science.7280665
  20. Vernia P, Camillo MD, Marinaro V, Caprilli R. Effect of predominant methanogenic flora on the outcome of lactose breath test in irritable bowel syndrome patients. Eur J Clin Nutr 2003;57:1116-9. https://doi.org/10.1038/sj.ejcn.1601651
  21. Perman JA, Modler S, Engel RR, Heldt G. Effect of ventilation on breath hydrogen measurements. J Lab Clin Med 1985;105:436-9.
  22. Thompson DG, Binfield P, De Belder A, O'Brien J, Warren S, Wilson M. Extra intestinal influences on exhaled breath hydrogen measurements during the investigation of gastrointestinal disease. Gut 1985;26:1349-52. https://doi.org/10.1136/gut.26.12.1349