DOI QR코드

DOI QR Code

OSC를 위한 라멘구조 PC조 공동주택의 PC 커튼월 외벽 및 바닥 접합부 단열계획 및 해석

Insulation Plan and Analysis for Curtain Wall Type PC(Precast Concrete) Outer Wall and Floor Joint of Rahmen Structure Apartment Built with PC for Off-Site Construction

  • 주나영 (이화여대 건축도시시스템공학과) ;
  • 송승영 (이화여대 건축도시시스템공학과)
  • Joo, Na-Young (Dept. of Architectural & Urban Systems Engineering, Ewha Womans University) ;
  • Song, Seung-Yeong (Dept. of Architectural & Urban Systems Engineering, Ewha Womans University)
  • 투고 : 2022.08.05
  • 심사 : 2022.09.13
  • 발행 : 2022.10.30

초록

The aim of this study is to find an effective insulation method for the curtain wall type PC(precast concrete) outer wall and floor joint of a rahmen structure apartment built with PC. The insulation performance of the existing case and alternatives in the recently constructed apartment building was evaluated through three-dimensional steady-state heat transfer simulation. As a result, it was found that the existing case needs to reduce thermal bridging effects caused by curtain wall corbels and fastening units and cover the upper fastening unit with sufficient thickness. The first alternative, which moved the position where the curtain wall corbel was supported to the upper part of the girder and sufficiently covered the upper fastening unit, showed that the effective U-factor decreased by 23.5% compared to the existing case. The additional insulation between the curtain wall and the girder of the first alternative reduced the effective U-factor by 32.4%. If the curtain wall corbel is removed, the effective U-factor is reduced by up to 36.3%, but structural analysis is required for field application.

키워드

과제정보

본 연구는 국토교통부/국토교통과학기술진흥원의 지원으로 수행 되었음.(과제번호 22ORPS-B158109-03)

참고문헌

  1. Choi, B. H., & Song, S. Y. (2021). Insulation performance comparison of curtain wall systems with existing pipe frames and truss-shaped insulation frames, Energies 2021, 14(15), 4682. https://doi.org/10.3390/en14154682
  2. Hwang, E. K., Lee, J. H. & Jung, Y. H. (2017). Improvement direction of legislation for the modular building activation. Journal of the Architectural Institute of Korea, 37(2), 1099-1099.
  3. ISO. (2017). Thermal bridges in building construction -Heat flows and surface temperatures - Detailed calculation(10211).
  4. ISO. (2017). Thermal performance of buildings -Transmission and ventilation heat transfer coefficients -Calculation method(13789).
  5. Jeong, M. K., Lee, S. J., Chang, Y. H., & Kwon, S. W.(2021). Smart quality inspection technology for on-site PC members based on Off-Site Construction(OSC). Journal of the Architectural Institute of Korea, 41(1), 745-746.
  6. Joo, N. Y., & Song, S. Y.(2021). Insulation performance comparison of apartment building envelopes composed of reinforced concrete and precast concrete. Journal of the Architectural Institute of Korea, 37(12), 265-275. https://doi.org/10.5659/JAIK.2021.37.12.265
  7. Jun, Y. H., Kang, T. K., Shin, E. Y., Kim, K. H., & Bae, B. Y.(2021). Deriving factors affecting schedule management in factory production of PC components through case analysis. Journal of the Architectural Institute of Korea, 41(1), 747-748.
  8. Jung, S. Y., & Yu, J. H.(2022). Application of DfMA in OSC projects. Review of Architecture and Building Science, 66(7), 19-21.
  9. KIAEBS S-13. (2020). Calculation method of thermal performance of thermal bridge breaker applied to thermal bridge in building envelope.
  10. Kim, Y. J., & Allard, A. (2014). Thermal response of precast concrete sandwich walls with various steel connectors for architectural buildings in cold regions, Energy and Buildings, 80, 137-148. https://doi.org/10.1016/j.enbuild.2014.05.022
  11. Korea Energy Agency. (2020). Commentary of Energy Saving Design Standards of Buildings.
  12. Korea Energy Agency. (2017). Energy Saving Design Standards of Buildings.
  13. Lee, J. M.(2022). Trends in revising and enacting codes and standards to boost Off-Site Construction in developed countries - Focusing on BPS 7014 & ICC 1200, 1205 -. Journal of the Architectural Institute of Korea, 38(3), 3-12. https://doi.org/10.5659/JAIK.2022.38.3.3
  14. Ministry of Land, Infrastructure and Transport(MLIT). (2016). Design Standard for Preventing Condensation in Apartment Buildings.
  15. Voellinger, T, Bassi, A & Heitel, M. (2014). Facilitating the incorporation of VIP into precast concrete sandwich panels, Energy and Buildings, 85, 666-671. https://doi.org/10.1016/j.enbuild.2014.05.038
  16. Zhai, X., Wang, Y., & Wang, X. (2018). Thermal performance of precast concrete sandwich walls with a novel hybrid connector, Energy and Buildings, 166, 109-121. https://doi.org/10.1016/j.enbuild.2018.01.070