DOI QR코드

DOI QR Code

Examining Improvement Factors and Incremental Costs Towards Zero Energy Building Certification for Public Order Modular Apartment Houses

공공발주 모듈러 공동주택의 제로에너지건축물 인증등급 달성을 위한 개선요소 및 증분비용 분석 사례 검토

  • Lee, Se-Yeon ( Dept. of Smart City Engineering, Hanyamg University) ;
  • Jung, Chan-Woo (Hanyang ERICA-Institute for Energy and The Environment, Hanyang University ERICA) ;
  • Ahn, Yong-Han (Dept. of Architectural Engineering, Hanyang University ERICA)
  • 이세연 (한양대 스마트시티공학과) ;
  • 정찬우 (한양대 ERICA 캠퍼스 환경에너지연구원) ;
  • 안용한 (한양대 ERICA 캠퍼스 건축학부)
  • Received : 2023.10.19
  • Accepted : 2023.11.22
  • Published : 2023.12.31

Abstract

This study examined the primary energy requirements and additional costs associated with different combinations of technology and improvement factors to achieve a zero-energy building (ZEB) grade for public order modular apartment houses. The analysis considered three stages of performance for six improvement factors. The findings revealed that individual enhancements to passive and active elements did not meet ZEB criteria. However, installing photovoltaic (PV) systems covering at least 40% of the rooftop area satisfied the ZEB 5th grade. To propose an effective combination of improvement factors for ZEB certification, the cost performance index was analyzed, and factors were prioritized accordingly. The analysis indicated incremental costs per unit area of 62,392 won for ZEB 5th grade, 96,380 won for ZEB 4th grade, and 120,389 won for ZEB 3rd grade. This study holds significance as it provides insights into energy performance and incremental costs during the introduction of zero-energy buildings and modular apartment houses.

Keywords

Acknowledgement

이 연구는 2023년도 산업통상자원부 및 산업기술평가관리원(KEIT) 연구비 지원에 의한 연구임('20015040')

References

  1. Chung, .J. S., Seal, W. J., Lim, S. H., & Park, G. S. (2019). Foundational study for implementation of rating 3 zero znergy in modular demonstration complex, Proceeding of Spring Conference of the Architectural Institute of Korea, 39(1), 469-472.
  2. Chung, M. H., Lee, S. J., & Park, J. C. (2021). Zero-energy planning with modular system in residential buildings, Journal of the Architectural Institute of Korea, 37(10), 159-164. https://doi.org/10.5659/JAIK.2021.37.10.159
  3. Hur. D. W., Lim. I. H., Kim, J. U., Park, S. C., Kim, Y. S., & Lee, M. J. (2018). Phased application technology for zero energy railway station - focusing on Jeongeup station on Honam line, Journal of the Korean Society for Railway, 12(6), 622-629.
  4. Jang, C. G., Lee, T. H., Choi, H. B., Lee, H. J., Cho, D. J., Cho. E. S., Lee, B. J., & Kim, J. H. (2021). 2030 LH Technical Standards for Zero Energy Housing, Korea Land and Housing Corporation, 288-289.
  5. Kim, H. G., & Kim, M. Y. (2017). Implementation of Optimal Energy Performance in Small Apartment Houses, Seoul Housing & Communities Corporation Urban Research Institute, 82-83.
  6. Kim, S. S., & Jin, T. S. (2018). An Institutional Study for The Activation of Zero Energy Building, Architecture & Urban Research Institute, 57-61.
  7. Kim, M. Y., Kim, H. G., & Hong, G. P. (2018). Design factors and initial cost by zero energy building rating systems through case study, KIEAE Journal, 18(2), 55-60.
  8. Lee, D. H., Kim, T. H., Seok, J. H., & Byun, S. Y. (2021). Analysis of energy performance of multi-unit dwelling by household plan using the building energy efficiency rating program, Journal of KIAEBS, 15(2), 200-212.
  9. Lee, S. Y., Jung, C. W., & Ahn, Y. H. (2023). A comparative analysis of the life cycle assessment of modular apartments and rc apartments. Journal of the Architectural Institute of Korea, 39(5), 232.
  10. Song, S. H., Son, J. R., Nam, S. H., Kim, J. W., & Kang, G. Y. (2022). A Study on Characteristics of Construction Costs and BoQ System for Public Modular Housing, Land & Housing Institution, 77-78.
  11. Won, .J. Y., & Tae, Y. R. (2021). A study on the capacity estimation of photovoltaic system applied to multi-unit dwelling by zero energy building certification grade, Journal of KIAEBS, 15(3), 283-285.