DOI QR코드

DOI QR Code

A Study on the Establishment of Design Criteria by Use for Energy Efficiency Design of Small-scale Buildings

소규모 건축물의 에너지효율설계를 위한 용도별 설계 기준 설정에 관한 연구

  • 박선효 (지속가능건축연구원) ;
  • 정용호 (청운대학교 설비소방학과) ;
  • 양자강 (대한기계설비산업연구원) ;
  • 안병욱 (대한건축학회 건축연구소)
  • Received : 2022.12.16
  • Accepted : 2023.03.06
  • Published : 2023.04.30

Abstract

The purpose of this study is to propose design conditions for small residential buildings to satisfy the building energy efficiency rating of 1++, which is the standard for Zero Energy Building Certification. Unlike non-residential buildings, residential buildings have a high standard of primary energy requirements required by grade, making it difficult to satisfy passive elements without additional energy production. The concept of average U-value by floor area was applied to the conditions of the comprehensive cladding thermal performance of non-residential buildings when it was first announced. The regions were divided into three categories: Central 1 (Chuncheon), Central 2 (Seoul), and Southern (Busan). The results of each region revealed that it was difficult to obtain a target grade of 1++ if only passive and active elements were strengthened and applied without energy production in all three regions. Accordingly, an additional analysis was conducted when solar panels, which are renewable energy, were applied based on a small four-story residential model. If solar panels were installed as much as 82.5Wh/m2a, it was possible to obtain target grades in all three regions. In addition, when a solar panel was installed as much as 55Wh/m2a, it was possible to obtain a target grade if the average U-value by floor area was less than 0.5W/m2K in Seoul, 0.4W/m2K in Chuncheon, and 0.92W/m2K in Busan.

Keywords

Acknowledgement

이 연구는 국토교통부/국토교통과학기술진흥원의 지원으로 수행되었음(과제번호 22AUDP-B151658-04)

References

  1. Lee, S.M., Lee, T.K., & Kim, J.U. (2018). A study on the investment review of passive and active elements through comparison of energy demand and generation variation of zero energy building, Journal of the Architectural Institute of Korea Planning & Design, 34(11), 13-22.
  2. Kim, J.H., Jo, S.Y., Kim, C.M., Jang, H.I., & Kim, S.S. (2018). Analysis of design parameters affecting zero energy buildings based on the building energy efficiency rating certified buildings - focused on educational research facilities, Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 12(4), 387-399.
  3. Park, S.H., Jung, Y.H., & Ahn, B.W. (2021). Synthetic envelope thermal performance for satisfying the building energy efficiency grade(1++) of a small-scale building, Journal of the Architectural Institute of Korea, 37(7), 143-150. https://doi.org/10.5659/JAIK.2021.37.7.143
  4. Won, J.Y., & Tae, Y.R. (2021). A study on the capacity estimation of photovoltaic system applied to multi-unit dwelling by zero energy building certification grade, Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 15(3), 279-288.