DOI QR코드

DOI QR Code

Dosimetric Comparison of Stereotactic Radiosurgery for Brain Metastases: Volumetric Modulated Arc Therapy vs. Dynamic Conformal Arc

  • Youngkuk Kim (Department of Radiation Oncology, Kosin University Gospel Hospital) ;
  • Sangwook Lim (Department of Radiation Oncology, Kosin University Gospel Hospital) ;
  • Ji Hoon Choi (Department of Radiation Oncology, Kosin University Gospel Hospital) ;
  • Kyung Ran Park (Department of Radiation Oncology, Kosin University Gospel Hospital)
  • Received : 2024.11.08
  • Accepted : 2024.12.16
  • Published : 2024.12.31

Abstract

Purpose: This study aimed to compare the dose characteristics of the volumetric modulated arc therapy (VMAT) and dynamic conformal arc (DCA) techniques for metastatic brain tumor treatment using various indices to evaluate the quality of the plan and provide insights into the clinical implications of each approach. Methods: Twelve patients with single metastatic brain tumors treated with VMAT were retrospectively analyzed. For comparison with DCA, identical geometric parameters (excluding multileaf collimators) were applied. Dose coverage, normal tissue sparing, and treatment efficiency were evaluated using indices such as CILIM98, CIICRU, CIRTOG, QCRTOG, CISALT, HTCISALT, and CIPADDIC. These indices were statistically assessed to evaluate the differences between VMAT and DCA. Results: VMAT was superior to DCA in most indices for both small and large planning target volumes (PTVs). DCA plans for large PTVs showed a higher V12Gy, exceeding 10 mL and failing to meet the recommended criteria (<10 mL). However, DCA required nearly half the monitor units (MUs) of VMAT, resulting in shorter treatment times. All indices, except for QCRTOG, demonstrated significant differences between VMAT and DCA. Conclusions: Careful consideration is necessary for larger PTVs when deciding a plan because DCA can occasionally result in V12Gy of a brain minus PTV >10 mL. Conversely, DCA provides the advantage of shorter treatment times because of its lower MU. This study highlights the importance of using a combination of indices to comprehensively assess treatment plan quality.

Keywords

References

  1. Deodato F, Cilla S, Macchia G, Torre G, Caravatta L, Mariano G, et al. Stereotactic radiosurgery (SRS) with volumetric modulated arc therapy (VMAT): interim results of a multiarm phase I trial (DESTROY-2). Clin Oncol (R Coll Radiol). 2014;26:748-756. https://doi.org/10.1016/j.clon.2014.08.005
  2. Shaw E, Kline R, Gillin M, Souhami L, Hirschfeld A, Dinapoli R, et al. Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys. 1993;27:1231-1239. https://doi.org/10.1016/0360-3016(93)90548-A
  3. Ladbury C, Pennock M, Yilmaz T, Ankrah NK, Andraos T, Gogineni E, et al. Stereotactic radiosurgery in the management of brain metastases: a case-based radiosurgery society practice guideline. Adv Radiat Oncol. 2023;9:101402. https://doi.org/10.1016/j.adro.2023.101402
  4. Soffietti R, Rudà R, Trevisan E. Brain metastases: current management and new developments. Curr Opin Oncol. 2008;20:676-684. https://doi.org/10.1097/CCO.0b013e32831186fe
  5. Grishchuk D, Dimitriadis A, Sahgal A, De Salles A, Fariselli L, Kotecha R, et al. ISRS technical guidelines for Stereotactic Radiosurgery: treatment of small brain metastases (≤1 cm in diameter). Pract Radiat Oncol. 2023;13:183-194. https://doi.org/10.1016/j.prro.2022.10.013
  6. Shaw E, Scott C, Souhami L, Dinapoli R, Kline R, Loeffler J, et al. Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: final report of RTOG protocol 90-05. Int J Radiat Oncol Biol Phys. 2000;47:291-298. https://doi.org/10.1016/S0360-3016(99)00507-6
  7. Lehrer EJ, Peterson JL, Zaorsky NG, Brown PD, Sahgal A, Chiang VL, et al. Single versus multifraction stereotactic radiosurgery for large brain metastases: an international meta-analysis of 24 trials. Int J Radiat Oncol Biol Phys. 2019;103:618-630. https://doi.org/10.1016/j.ijrobp.2018.10.038
  8. Chang EL, Selek U, Hassenbusch SJ 3rd, Maor MH, Allen PK, Mahajan A, et al. Outcome variation among "radioresistant" brain metastases treated with stereotactic radiosurgery. Neurosurgery. 2005;56:936-945; discussion 936-945.
  9. Schiff D, Messersmith H, Brastianos PK, Brown PD, Burri S, Dunn IF, et al. Radiation therapy for brain metastases: ASCO guideline endorsement of ASTRO guideline. J Clin Oncol. 2022;40:2271-2276. https://doi.org/10.1200/JCO.22.00333
  10. Flickinger JC, Kondziolka D, Lunsford LD, Kassam A, Phuong LK, Liscak R, et al. Development of a model to predict permanent symptomatic postradiosurgery injury for arteriovenous malformation patients. Arteriovenous Malformation Radiosurgery Study Group. Int J Radiat Oncol Biol Phys. 2000;46:1143-1148. https://doi.org/10.1016/S0360-3016(99)00513-1
  11. Blonigen BJ, Steinmetz RD, Levin L, Lamba MA, Warnick RE, Breneman JC. Irradiated volume as a predictor of brain radionecrosis after linear accelerator stereotactic radiosurgery. Int J Radiat Oncol Biol Phys. 2010;77:996-1001. https://doi.org/10.1016/j.ijrobp.2009.06.006
  12. Lee J, Kim HJ, Kim WC. CyberKnife-based stereotactic radiosurgery or fractionated stereotactic radiotherapy in older patients with brain metastases from non-small cell lung cancer. Radiat Oncol J. 2023;41:258-266. https://doi.org/10.3857/roj.2023.00563
  13. Fiagbedzi E, Hasford F, Tagoe SN. Impact of planning target volume margins in stereotactic radiosurgery for brain metastasis: a review. Prog Med Phys. 2024;35:1-9. https://doi.org/10.14316/pmp.2024.35.1.1
  14. Oshiro Y, Mizumoto M, Kato Y, Tsuchida Y, Tsuboi K, Sakae T, et al. Single isocenter dynamic conformal arcs-based radiosurgery for brain metastases: dosimetric comparison with Cyberknife and clinical investigation. Tech Innov Patient Support Radiat Oncol. 2024;29:100235. https://doi.org/10.1016/j.tipsro.2024.100235
  15. Chambrelant I, Jarnet D, Le Fèvre C, Kuntz L, Jacob J, Jenny C, et al. Comparative study of dynamic conformal arc therapy and volumetric modulated arc therapy for treating single brain metastases: a retrospective analysis of dosimetric and clinical outcomes. Phys Imaging Radiat Oncol. 2024;30:100591. https://doi.org/10.1016/j.phro.2024.100591
  16. He Z, Ho MKJ, Lee WYV, Law HY, Wong YWV, Leung TW, et al. Frameless versus frame-based stereotactic radiosurgery for intracranial arteriovenous malformations: a propensity-matched analysis. Clin Transl Radiat Oncol. 2023;41:100642. https://doi.org/10.1016/j.ctro.2023.100642
  17. Wen N, Snyder KC, Scheib SG, Schmelzer P, Qin Y, Li H, et al. Technical note: evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system. Med Phys. 2016;43:2527. https://doi.org/10.1118/1.4947199
  18. Minniti G, Scaringi C, Clarke E, Valeriani M, Osti M, Enrici RM. Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomes. Radiat Oncol. 2011;6:158. https://doi.org/10.1186/1748-717X-6-158
  19. Feuvret L, Noël G, Mazeron JJ, Bey P. Conformity index: a review. Int J Radiat Oncol Biol Phys. 2006;64:333-342. https://doi.org/10.1016/j.ijrobp.2005.09.028
  20. Stanley J, Breitman K, Dunscombe P, Spencer DP, Lau H. Evaluation of stereotactic radiosurgery conformity indices for 170 target volumes in patients with brain metastases. J Appl Clin Med Phys. 2011;12:245-253. https://doi.org/10.1120/jacmp.v12i2.3449
  21. Paddick I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. J Neurosurg. 2000;93 Suppl 3:219-222. https://doi.org/10.3171/jns.2000.93.supplement_3.0219
  22. Molinier J, Kerr C, Simeon S, Ailleres N, Charissoux M, Azria D, et al. Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery. J Appl Clin Med Phys. 2016;17:92-101. https://doi.org/10.1120/jacmp.v17i1.5677
  23. Torizuka D, Uto M, Takehana K, Mizowaki T. Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis. J Radiat Res. 2021;62:1114-1119. https://doi.org/10.1093/jrr/rrab092
  24. Kuperman V Y, Altundal Y, Kandel S, Kouskoulas TN. Dose conformity and falloff in single-lesion intracranial SRS with DCA and VMAT methods. J Appl Clin Med Phys. 2024;25:e14415. https://doi.org/10.1002/acm2.14415