DOI QR코드

DOI QR Code

순환식 지하수 수막시스템 그린하우스 난방을 위한 스탠딩컬럼웰 열교환율 산정

Estimation of Heat Exchange Rate of Standing Column Well for Sustainable Groundwater Curtain for Greenhouse Heating

  • 심병완 (한국지질자원연구원 기후변화대응연구본부) ;
  • 백승균 (지마텍 주식회사) ;
  • 정성훈 (한국해양대학교 산업기술연구소)
  • 투고 : 2024.05.10
  • 심사 : 2024.05.30
  • 발행 : 2024.06.01

초록

In order to design a standing column well (SCW) for a sustainable groundwater curtain system for greenhouse heating, we conducted parameter sensitivity tests. These tests simulated the outlet temperature changes of the SCW in a groundwater recirculating greenhouse cultivation system. Our modeling considered ground thermal conductivity and hydrogeological conditions. Specifically, we examined several factors, including SCW length, enhanced thermal conductivity of the ground, and groundwater circulation rate. The simulation results indicated that there was not a significant difference in the heat exchange rate based on the characteristics of enhanced thermal conductivity. However, we anticipate a substantial difference in the case of varying SCW lengths. Therefore, we conclude that the simulation results are primarily influenced by conductive heat exchange values, as the circulating water remains at a constant groundwater level.

키워드

과제정보

본 연구는 한국지질자원연구원 지하수환경연구센터 기본사업 '기후변화대응 대용량지하수 확보 및 최적활용 기술개발(24-3411)'의 지원에 의하여 수행되었음.

참고문헌

  1. Lee, C. K., 2022. Challenges and Solutions for Protected Horticulture in the Carbon-Neutral Era. The conference proceeding of Korean Soc. for Horticultural Sci., pp. 39-39.
  2. Lee, J. Y., Yi, M. J., Lee, J. M., Ahn, K. H., Won, J. H., Moon, S. H., and Cho, M. J., 2006. Parametric and nonparametric trend analysis of groundwater data obtained from national groundwater monitoring stations. Journal of Soil and Groundwater Environment, Vol. 11, No. 2, pp. 56-67.
  3. Shin, J., Hwang, S., Kim, Y., Kim, J., and Won, B., 2016. Applications of geophysical approaches to characterize riverside alluvium and porous aquifers to a water curtain cultivation area. J. Geol. Soc. Korea, Vol. 52, No. 4, pp. 475-491. https://doi.org/10.14770/jgsk.2016.52.4.475
  4. Chang, S., Chung I., Kim, Y., and Moon, S., 20, 2016. Long-term groundwater budget analysis based on integrated hydrological model for water curtain cultivation site: Case study of Cheongweon, Korea. Geol. Soc. Korea, Vol. 52, No. 3, pp. 201-210. https://doi.org/10.14770/jgsk.2016.52.3.201
  5. Deng, Z., Rees, S. J., and Spitler, J. D., 2005, A Model for Annual Simulation of Standing Column Well Ground Heat Exchangers. International Journal of Heating Ventilation Air C, Vol. 11, No. 4, 637-656. https://doi.org/10.1080/10789669.2005.10391159
  6. Kim, J. and Nam, Y., 2015. A numerical study on system performance of groundwater heat pumps. Energies, Vol. 9, No. 1, p. 4.
  7. Seo, B. M., Hong, S. H., Choi, J. M., and Lee, K. H., 2019. Part load ratio characteristics and energy saving performance of standing column well geothermal heat pump system assisted with storage tank in an apartment. Energy, Vol. 174, pp. 1060-1078. https://doi.org/10.1016/j.energy.2019.03.029
  8. Lee, S. and Nam, Y., 2013. Study on the performance analysis of SCW geothermal system by simulation and monitoring. Journal of the Korean Society for Geothermal and Hydrothermal Energy, Vol. 9, No. 2, pp. 8-15. https://doi.org/10.17664/ksgee.2013.9.2.008
  9. Kim, W., Lee, S., Jeon, J., Kim, M., Kim, M., and Jeon, Y., 2016. Improved design method of open loop geothermal system and its applications. New & Renewable Energy, Vol. 12, No. 4, pp. 122-130. https://doi.org/10.7849/ksnre.2016.12.12.4.122
  10. Lee, K. H., Do, S. L., and Choi, J. M., 2019. A Study on the SCW Ground Source Heat Pump System Technologies for Residential Cluster Homes. Journal of the Korean Society for Geothermal and Hydrothermal Energy, Vol. 15, No. 3, pp. 14-20.
  11. Deng, Z., 2004. Modeling of standing column wells in ground source heat pump systems. Oklahoma State University.
  12. Han, C., Zhu, C., Shen, Y., and Yu, X. B., 2022. Energy, environmental and economic performance evaluation of energy pile system under different climate conditions. Energy Conversion and Management, Vol. 252, p. 115041.
  13. Rees, S. J., Spitler, J., Deng, Z., Orio, C., and Johnson, C. (2004). A study of geothermal heat pump and standing column well performance. ASHRAE Transactions, Vol. 110, No. 1, 3-13.
  14. Spitler, J. D., Xing, L., and Malayappan, V., 2014. A simple tool for simulation of ground source heat pump systems. In IEA Heat Pump Conf., Montreal, Canada.
  15. Nguyen, A., Pasquier, P., and Marcotte, D., 2015. Thermal resistance and capacity model for standing column wells operating under a bleed control. Renewable Energy, Vol. 76, pp. 743-756. https://doi.org/10.1016/j.renene.2014.11.080
  16. Beurcq, C., 2019. Control strategies for standing column wells in a cold climate, Master's thesis, Ecole Polytechnique, Montreal, Canada.
  17. O'Neill, Z. D., Spitler, J. D., and Rees, S., 2006. Performance analysis of standing column well ground heat exchanger systems. ASHRAE Transactions, Vol. 112, No. 2, pp. 633-644.
  18. Jeon, S., Koo, M., and Kang, I., 2005. Statistical analysis of aquifer characteristics using pumping test data of national groundwater monitoring wells for Korea, Journal of Soil and Groundwater Environment, Vol. 10, No. 6, 32-44.
  19. Shim, B. O. and Park, C. H., 2013. Ground thermal conductivity for (ground source heat pumps) GSHPs in Korea. Energy, Vol. 56, pp. 167-174. https://doi.org/10.1016/j.energy.2013.04.059
  20. Nam, S. W., Heo, Y. J., Sim, O. J., Sim, S. I., and Lee, H. S., 1998, Thermal insulation effect of a double film water curtain system in greenhouse, The conference proceeding of Korean Soc. of Bio-Environment Control, Vol. 7, No. 1, pp. 16-21.