DOI QR코드

DOI QR Code

방사선 작업종사자 안전을 위한 실시간 능동형 안전관리 플랫폼과 데이터 수집 디바이스 개발 연구

Development of a Real-Time Active Safety Management Platform and Data Collection Device for the Safety of Radiation Workers

  • 박길순 ((주)뉴케어 기술연구소) ;
  • 배기훈 ((주)뉴케어 기술연구소) ;
  • 김용권 ((주)뉴케어 기술연구소) ;
  • 서원기 ((주)넥스트코어테크놀로지)
  • 투고 : 2024.09.02
  • 심사 : 2024.09.25
  • 발행 : 2024.09.30

초록

Radiation work always carries the risk of radiation exposure, so regulatory agencies manage it through licensing when high exposure is expected. However, due to passive management methods using TLD, etc., there are cases where risk management is done after an incident occurs or the incident is covered up. In this study, we developed a system to manage the location of radiation work and the risk of workers in real time through a safety management platform and a location-based personal dosimeter. The safety platform server receives data from the developed personal dosimeter in real time and manages risks in three steps for each worker using location and dose rate, and can predict risks and generate alarms in real time. The personal dosimeter transmits the location and dose rate of the worker in real time using GPS and LTE communication. The developed safety management platform and personal dosimeter were verified through a field test to receive real-time data of the location and dose rate data of the worker, and the risk management function according to the individual dose rate was verified.

키워드

과제정보

본 연구는 2022년도 중소벤처기업부의 기술개발사업[S3324625]과 산업통상자원부(MOTIE) 및 한국에너지기술평가원(KETEP)의 지원을 받아 수행한 연구임(No. 20224B10300090).

참고문헌

  1. https://www.nea.gov.sg/our-services/radiation-safety/radiation-protection-services. 
  2. Enforcement Decree of the Atomic Energy Safety Act, Equipment Standards for Permitting Production of Radioisotopes, etc. 
  3. Qingxi Yang, Qiaokun Kang, Qingyang Huang, Zenghui Cui, Yu Bai and Huanan Wei, Linear correlation analysis of ammunition storage environment based on Pearson correlation analysis. https://doi.org/10.1088/1742-6596/1948/1/012064. 
  4. Joseph Lee Rodgers & W. Alan Nicewander, Thirteen Ways to Look at the Correlation Coefficient. https://doi.org/10.1080/00031305.1988.10475524. 
  5. P. Buzhan, A. Karakash, Yu. Teverovskiy, Silicon Photomultiplier and CsI(Tl) scintillator in application to portable H*(10) dosimeter, https://doi.org/10.1016/j.nima.2017.11.067. 
  6. Sapna Kumari C, Thrishank H S, Design and Development Of Scintillation Based Gamma Dosimeter Using SIPM Detector. https://doi.org/10.1109/MysuruCon55714.2022.9972694.