DOI QR코드

DOI QR Code

Bibliometric Analysis of Monte Carlo-Based Medical Physics Research in Korea (2015-2024)

  • Gahee Son (Department of Nuclear Engineering, Hanyang University) ;
  • Seok-Ho Lee (Department of Integrative Medicine, Yonsei University College of Medicine) ;
  • Yongdo Yun (Department of Radiation Oncology, Heavy Ion Therapy Research Institute, Yonsei Cancer Center, Yonsei University College of Medicine) ;
  • Min Cheol Han (Department of Radiation Oncology, Heavy Ion Therapy Research Institute, Yonsei Cancer Center, Yonsei University College of Medicine) ;
  • Jin Sung Kim (Department of Radiation Oncology, Heavy Ion Therapy Research Institute, Yonsei Cancer Center, Yonsei University College of Medicine) ;
  • Chan Hyeong Kim (Department of Nuclear Engineering, Hanyang University)
  • Received : 2025.08.26
  • Accepted : 2025.11.05
  • Published : 2025.12.31

Abstract

This study analyzed Monte Carlo (MC)-based medical physics research in Korea between 2015-2024 with a focus on publication trends, research themes, and collaboration patterns. A bibliometric analysis of 310 publications that were retrieved from the Scopus and Google Scholar databases was performed. Here, publication trends, journal impact, and simulation toolkit usage were assessed quantitatively. In addition, co-occurrence and keyword network analyses were conducted to investigate thematic patterns. Moreover, author collaboration was examined institutionally and internationally. The findings of this study revealed steady research productivity, with annual publication outputs ranging from 25 to 40 papers and an increasing proportion of papers published in high-impact Science Citation Index Expanded-indexed journals (88.9%), representing a qualitative shift in publication strategies. Thematically, research in this field focuses on radiation dosimetry and medical imaging, with the widespread use of MC codes, e.g., Geant4 and its derivative toolkits in 54.7% of studies, as well as MC N-Particle (MCNP) in 13.2% of studies, across various clinical applications. A distinct feature of the Korean research environment is active domestic collaboration, which was observed in 51.0% of publications. In contrast, international collaboration remains comparatively limited (21.0%). Emerging topics, e.g., artificial intelligence (AI), have gained global attention; however, only 2.3% of Korean MC-based research incorporated AI-related approaches, reflecting a more conservative research focus than international trends. Korean MC-based medical physics research has maintained stable output, with an increasing emphasis on quality and clinical relevance. Promoting interdisciplinary research, fostering international collaboration, and integrating emerging technologies, e.g., AI, are essential to further advance the field and align it with global developments. These efforts are expected to enhance the precision and clinical utility of MC simulations and ensure continued progress in medical physics.

Keywords

Acknowledgement

This study was supported by a faculty research grant from Yonsei University College of Medicine (6-2023-0085).

References

  1. Amato E, Lizio D, Baldari S: Applications of the Monte Carlo method in medical physics. Medical physics. Nova Science Publishers; 2013:105-113.
  2. Ljungberg M, Strand SE, King MA. Monte Carlo calculations in nuclear medicine: applications in diagnostic imaging. 2nd ed. CRC Press; 2013.
  3. Rogers DW, Faddegon BA, Ding GX, Ma CM, We J, Mackie TR. BEAM: a Monte Carlo code to simulate radiotherapy treatment units. Med Phys. 1995;22:503-524. https://doi.org/10.1118/1.597552
  4. Chetty IJ, Curran B, Cygler JE, DeMarco JJ, Ezzell G, Faddegon BA, et al. Report of the AAPM Task Group No. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys. 2007;34:4818-4853. https://doi.org/10.1118/1.2795842
  5. Fippel M, Soukup M. A Monte Carlo dose calculation algorithm for proton therapy. Med Phys. 2004;31:2263-2273. https://doi.org/10.1118/1.1769631
  6. Jabbari K. Review of fast monte carlo codes for dose calculation in radiation therapy treatment planning. J Med Signals Sens. 2011;1:73-86. https://doi.org/10.4103/2228-7477.83522
  7. Rogers DW. Fifty years of Monte Carlo simulations for medical physics. Phys Med Biol. 2006;51:R287-R301. https://doi.org/10.1088/0031-9155/51/13/R17
  8. Verhaegen F, Seuntjens J. Monte Carlo modelling of external radiotherapy photon beams. Phys Med Biol. 2003;48:R107-R164. https://doi.org/10.1088/0031-9155/48/21/R01
  9. Ghaseminejad S, Mesbahi A, Khajeali A, Farajollahi AR. Dosimetric evaluation of small IMRT beamlets in the presence of bone inhomogeneity using NIPAM polymer gel and Monte Carlo simulation. Radiat Meas. 2017;105:62-69. https://doi.org/10.1016/j.radmeas.2017.08.002
  10. Pokhrel D, McClinton C, Sood S, Badkul R, Saleh H, Jiang H, et al. Monte Carlo evaluation of tissue heterogeneities corrections in the treatment of head and neck cancer patients using stereotactic radiotherapy. J Appl Clin Med Phys. 2016;17:258-270. https://doi.org/10.1120/jacmp.v17i2.6055
  11. Salman MD, Radzi YM, Rahman AA, Oglat AA, Dheyab MA. Advancements and applications of dosimetry techniques in modern medical radiation therapy: a comprehensive review. J Radioanal Nucl Chem. 2024;333:3713-3737. https://doi.org/10.1007/s10967-024-09517-3
  12. Kim E, Jang WI, Yang K, Kim MS, Yoo HJ, Paik EK, et al. Clinical utilization of radiation therapy in Korea between 2017 and 2019. Radiat Oncol J. 2022;40:251-259. https://doi.org/10.3857/roj.2022.00500
  13. Chung K, Kim J, Kim DH, Ahn S, Han Y. The proton therapy nozzles at Samsung Medical Center: a Monte Carlo simulation study using TOPAS. J Korean Phys Soc. 2015;67:170-174. https://doi.org/10.3938/jkps.67.170
  14. Jang DG, Kang S, Kim J. Kim C. An analysis of exposure dose on hands of radiation workers using a Monte Carlo simulation in nuclear medicine. J Radiol Sci Technol. 2015;38:477-482. https://doi.org/10.17946/JRST.
  15. Kim DH, Cho S, Jo K, Shin E, Hong CS, Han Y, et al. Proton range verification in inhomogeneous tissue: treatment planning system vs. measurement vs. Monte Carlo simulation. PLoS One. 2018;13:e0193904. https://doi.org/10.1371/journal.pone.0193904
  16. Shin WG, Testa M, Kim HS, Jeong JH, Lee SB, Kim YJ, et al. Independent dose verification system with Monte Carlo simulations using TOPAS for passive scattering proton therapy at the National Cancer Center in Korea. Phys Med Biol. 2017;62:7598-7616. https://doi.org/10.1088/1361-6560/aa8663
  17. Son K, Cho S, Kim JS, Han Y, Ju SG, Choi DH. Evaluation of radiation dose to organs during kilovoltage cone-beam computed tomography using Monte Carlo simulation.] Appl Clin Med Phys. 2014;15:4556. https://doi.org/10.1120/jacmp.v15i2.4556
  18. Broadus RN. Toward a definition of "bibliometrics". Scientometrics. 1987;12:373-379. https://doi.org/10.1007/BF02016680
  19. Diodato VP, Gellatly P. Dictionary of bibliometrics. Taylor and Francis; 2013.
  20. Donthu N, Kumar S, Mukherjee D, Pandey N, Lim WM. How to conduct a bibliometric analysis: an overview and guidelines. J Bus Res. 2021;133:285-296. https://doi.org/10.1016/j.jbusres.2021.04.070
  21. Zupic I, Čater T. Bibliometric methods in management and organization. Organ Res Methods. 2015;18:429-472. https://doi.org/10.1177/1094428114562629
  22. van Eck NJ, Waltman L. Software survey: VOSviewer, a computer program for bibliometric mapping. Scientometrics. 2010;84:523-538. https://doi.org/10.1007/s11192-009-0146-3
  23. Lv M, Feng Y, Zeng S, Zhang Y, Shen W, Guan W, et al. A bibliometrics analysis based on the application of artificial intelligence in the field of radiotherapy from 2003 to 2023. Radiat Oncol. 2024;19:157. https://doi.org/10.1186/s13014-024-02551-1