References
- Banerjee R, Kamrava M. Brachytherapy in the treatment of cervical cancer: a review. Int J Womens Health. 2014;6:555-564.
- Koukourakis G, Kelekis N, Armonis V, Kouloulias V. Brachytherapy for prostate cancer: a systematic review. Adv Urol. 2009;2009:327945. https://doi.org/10.1155/2009/327945
- Skowronek J, Chicheł A. Brachytherapy in breast cancer: an effective alternative. Prz Menopauzalny. 2014;13:48-55. https://doi.org/10.5114/pm.2014.41090
- Choe SI, Lee Y, Habashi R, Samarasinghe Y, Lee MH, McKechnie T, et al. The role of brachytherapy in treatment of stage I esophageal cancer: a systematic review. Brachytherapy. 2022;21:877-886. https://doi.org/10.1016/j.brachy.2022.05.007
- Skowronek J. Brachytherapy in the treatment of skin cancer: an overview. Postepy Dermatol Alergol. 2015;32:362-367. https://doi.org/10.5114/pdia.2015.54746
- Vandana S, Sharma SD. Long term response stability of a well-type ionization chamber used in calibration of high dose rate brachytherapy sources. J Med Phys. 2010;35:100-103. https://doi.org/10.4103/0971-6203.62200
- Saminathan S, Godson HF, Ponmalar R, Manickam R, Mazarello J. Dosimetric evaluation of newly developed well-type ionization chamber for use in the calibration of brachytherapy sources. J Med Phys. 2016;41:234-239. https://doi.org/10.4103/0971-6203.195187
- Keehan S, Smith RL, Butler D. HDR brachytherapy well chamber calibration and stability evaluated over twenty years of clinical use. Brachytherapy. 2021;20:257-264. https://doi.org/10.1016/j.brachy.2020.08.017
- Steidley KD. Use of radiochromic dosimetry film for HDR brachytherapy quality assurance. Med Dosim. 1998;23:37-38. https://doi.org/10.1016/S0958-3947(97)00114-3
- Asgharizadeh S, Bekerat H, Syme A, Aldelaijan S, DeBlois F, Vuong T, et al. Radiochromic film-based quality assurance for CT-based high-dose-rate brachytherapy. Brachytherapy. 2015;14:578-585. https://doi.org/10.1016/j.brachy.2015.02.192
- Oustous A, Airouss Z, El Attaoui Y, Oustous Y, Khalis M, Sebihi R. Dosimetry evaluation of 192Ir Flexisource using gafchromic EBT3 film. J Radiother Pract. 2024;23:e24. https://doi.org/10.1017/S1460396924000177
- Awunor OA. Assessment of a source position checking tool for the quality assurance of transfer tubes used in HDR 192Ir brachytherapy treatments. Brachytherapy. 2018;17:628-633. https://doi.org/10.1016/j.brachy.2017.12.001
- Küçücük H, Şenkesen Ö, Göksel EO. Quality assurance in brachytherapy. Turk J Oncol. 2019;34(Supp 1):29–37. https://doi.org/10.5505/tjo.2018.1954
- Zhang Z. A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell. 2000;22:1330-1334. https://doi.org/10.1109/34.888718
- Hunt B, Cutajar D, Petasecca M, Rosenfeld A, Howie A, Bucci J, et al. HDR brachytherapy afterloader quality assurance optimization using monolithic silicon strip detectors. Med Phys. 2024;51:4581-4590. https://doi.org/10.1002/mp.v51.7
- Zhang S, Deng K, Duan R, Geng X. Hi-speed USB signal long-distance communication and test scheme design based on Ethernet communication. IOP Conf Ser Earth Environ Sci. 2021;632:042060. https://doi.org/10.1088/1755-1315/632/4/042060
- Hong Z, Sun S, Tong X, Zhou R, Pan H, Zhang Y, et al. Adaptive buffer capture and storage for high-speed cameras. IEEE Access. 2023;11:14550-14562.