Implementation and Long-Term Assessment of a Scintillator-Based High Dose Rate Brachytherapy Quality Assurance System in a Clinical Environment

  • Chanil Jeon (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Jusung Kim (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Geon Oh (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Jong Hwi Jeong (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Hak Soo Kim (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Chankyu Kim (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Dongho Shin (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Se Byeong Lee (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center) ;
  • Sang Hyoun Choi (Department of Radiation Oncology, Korea Cancer Center Hospital) ;
  • Ui-Jung Hwang (Department of Radiation Oncology, College of Medicine, Chungnam National University) ;
  • Young Kyung Lim (Department of Radiation Oncology, Proton Therapy Center, National Cancer Center)
  • Received : 2025.11.17
  • Accepted : 2025.12.05
  • Published : 2025.12.31

Abstract

Purpose: Brachytherapy is a form of radiotherapy that delivers highly localized radiation to target tissues, minimizing adverse effects on surrounding healthy cells. To further reduce these side effects, precise and reliable quality assurance (QA) is essential, and the effective integration of QA procedures into the clinical workflow is highly desirable. In this study, we developed a scintillator-based QA system for brachytherapy and implemented it in the clinical setting. The stability and reliability of the system were thoroughly evaluated through the analysis of long-term measurement data. Methods: The system consisted of a plastic-based scintillator plate and a GigE (Gigabit Ethernet) camera, both housed within a light-tight dark box. Three independent channels were integrated into the scintillator area, allowing brachytherapy catheters to be positioned via transfer tube connections. Using this setup, positional and temporal QA tests were conducted over approximately one year, during which the accuracy and stability of the system were evaluated throughout this period. Results: For positional QA performed with the developed system, most measurements demonstrated deviations of less than 1 mm from the reference positions. The system also effectively detected end position offsets associated with source exchange events. Temporal QA, analyzed on a camera frame basis, revealed discrepancies of mostly 0.1 to 0.2 seconds from the planned dwell times, indicating stable and consistent timing accuracy. Conclusions: Through long-term validation, this study demonstrated the accuracy and stability of a brachytherapy QA system composed of a scintillator and GigE camera. Further research will focus on developing and validating QA devices for intensity-modulated brachytherapy.

Keywords

Acknowledgement

The authors partially used an AI language tool for grammar refinement and language editing. The responsibility for all scientific content remains solely with the authors.

References

  1. Banerjee R, Kamrava M. Brachytherapy in the treatment of cervical cancer: a review. Int J Womens Health. 2014;6:555-564.
  2. Koukourakis G, Kelekis N, Armonis V, Kouloulias V. Brachytherapy for prostate cancer: a systematic review. Adv Urol. 2009;2009:327945. https://doi.org/10.1155/2009/327945
  3. Skowronek J, Chicheł A. Brachytherapy in breast cancer: an effective alternative. Prz Menopauzalny. 2014;13:48-55. https://doi.org/10.5114/pm.2014.41090
  4. Choe SI, Lee Y, Habashi R, Samarasinghe Y, Lee MH, McKechnie T, et al. The role of brachytherapy in treatment of stage I esophageal cancer: a systematic review. Brachytherapy. 2022;21:877-886. https://doi.org/10.1016/j.brachy.2022.05.007
  5. Skowronek J. Brachytherapy in the treatment of skin cancer: an overview. Postepy Dermatol Alergol. 2015;32:362-367. https://doi.org/10.5114/pdia.2015.54746
  6. Vandana S, Sharma SD. Long term response stability of a well-type ionization chamber used in calibration of high dose rate brachytherapy sources. J Med Phys. 2010;35:100-103. https://doi.org/10.4103/0971-6203.62200
  7. Saminathan S, Godson HF, Ponmalar R, Manickam R, Mazarello J. Dosimetric evaluation of newly developed well-type ionization chamber for use in the calibration of brachytherapy sources. J Med Phys. 2016;41:234-239. https://doi.org/10.4103/0971-6203.195187
  8. Keehan S, Smith RL, Butler D. HDR brachytherapy well chamber calibration and stability evaluated over twenty years of clinical use. Brachytherapy. 2021;20:257-264. https://doi.org/10.1016/j.brachy.2020.08.017
  9. Steidley KD. Use of radiochromic dosimetry film for HDR brachytherapy quality assurance. Med Dosim. 1998;23:37-38. https://doi.org/10.1016/S0958-3947(97)00114-3
  10. Asgharizadeh S, Bekerat H, Syme A, Aldelaijan S, DeBlois F, Vuong T, et al. Radiochromic film-based quality assurance for CT-based high-dose-rate brachytherapy. Brachytherapy. 2015;14:578-585. https://doi.org/10.1016/j.brachy.2015.02.192
  11. Oustous A, Airouss Z, El Attaoui Y, Oustous Y, Khalis M, Sebihi R. Dosimetry evaluation of 192Ir Flexisource using gafchromic EBT3 film. J Radiother Pract. 2024;23:e24. https://doi.org/10.1017/S1460396924000177
  12. Awunor OA. Assessment of a source position checking tool for the quality assurance of transfer tubes used in HDR 192Ir brachytherapy treatments. Brachytherapy. 2018;17:628-633. https://doi.org/10.1016/j.brachy.2017.12.001
  13. Küçücük H, Şenkesen Ö, Göksel EO. Quality assurance in brachytherapy. Turk J Oncol. 2019;34(Supp 1):29–37. https://doi.org/10.5505/tjo.2018.1954
  14. Zhang Z. A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell. 2000;22:1330-1334. https://doi.org/10.1109/34.888718
  15. Hunt B, Cutajar D, Petasecca M, Rosenfeld A, Howie A, Bucci J, et al. HDR brachytherapy afterloader quality assurance optimization using monolithic silicon strip detectors. Med Phys. 2024;51:4581-4590. https://doi.org/10.1002/mp.v51.7
  16. Zhang S, Deng K, Duan R, Geng X. Hi-speed USB signal long-distance communication and test scheme design based on Ethernet communication. IOP Conf Ser Earth Environ Sci. 2021;632:042060. https://doi.org/10.1088/1755-1315/632/4/042060
  17. Hong Z, Sun S, Tong X, Zhou R, Pan H, Zhang Y, et al. Adaptive buffer capture and storage for high-speed cameras. IEEE Access. 2023;11:14550-14562.