DOI QR코드

DOI QR Code

Development of Gas Sensor Based on a Light Intensity Analysis of a Webcam Image:Application to Gas Uptake and Diffusivity Measurements in Gas-Charged Polymer Materials

웹캠 이미지 빛의 밝기 분석에 기반한 가스 센서 개발: 가스가 충전된 고분자 소재의 가스 충전량과 확산도 측정에 활용

  • Jihun Lee (Department of Measurement Science, University of Science and Technology)
  • 이지훈 (한국과학기술대학원대학교 측정과학전공)
  • Received : 2025.02.15
  • Accepted : 2025.03.18
  • Published : 2025.04.30

Abstract

A gas sensor was developed to quantitatively analyze gas concentration and diffusivity by monitoring water level changes in a sealed graduated cylinder containing water and a gas-charged sample. As gas is released from the sample, a crescent-shaped bright boundary forms at the interface between the water and the released gas, which is recorded over time using a digital webcam. By analyzing the sequential time variation in pixel brightness from the captured images, the sensor enables precise measurement of gas concentration and diffusivity, combined with calculations based on the ideal gas equation. The developed sensor responds instantly within one second and can measure gas concentrations ranging from 1 wt·ppm (weight parts per million) to 1,000 wt·ppm, with adjustable sensitivity and measurement range. This low-cost sensor applies to the quantitative analysis of gases such as H2, He, N2, O2, and Ar, as well as studies on gas diffusion and permeability in various materials. This method offers a simple and cost-effective approach and facilitates real-time gas analysis and monitoring.

기체가 충전된 시료와 물이 담긴 밀폐된 눈금 실린더에서 수위 변화를 모니터링하여 기체 농도와 확산도를 정량적으로 분석하기 위한 가스 센서가 개발되었다. 시료에서 기체가 방출되면, 물과 방출된 기체의 경계에서 초승달 모양의 밝은 경계선이 형성되며, 이는 디지털 웹캠을 사용하여 시간에 따라 기록된다. 캡처된 이미지에서 픽셀 밝기의 시간에 따른 변화를 분석함으로써, 이 센서는 이상기체 방정식을 기반으로 한 계산과 결합하여 기체 농도와 확산도를 정밀하게 측정할 수 있다. 개발된 센서는 1초 이내에 즉각적으로 반응하며, 1 wt·ppm (무게 백만분율)에서 1,000 wt·ppm 범위의 기체 농도를 측정할 수 있으며, 감도와 측정범위도 조정 가능하다. 이 저비용 센서는 H2, He, N2, O2, Ar 등의 다양한 기체의 정량 분석뿐만 아니라, 다양한 재료에서의 기체 확산 및 투과 연구에도 활용될 수 있다. 본 방법은 간단하고 비용 효율적인 접근 방식을 제공함으로써 실시간 기체 분석 및 모니터링을 가능하게 한다.

Keywords

1. 서론

가스 센서는 이산화탄소, 일산화탄소, 산소, 수소, 유독 가스 등의 특정 가스의 존재와 농도를 계측하는 장치이다(Jung et al., 2021a, 2021b, 2021c; 2024a; Kang et al., 2022; Li et al., 2024; Mohapatra et al., 2015; Murthy, 2024; Wang et al., 2024; Yang et al., 2018). 이러한 센서는 효과적인 탐지 및 안전 모니터링에 필수적이며, 의료 진단, 산업 가스 모니터링, 공기 질 보증, 환경 모니터링, 자동차 배출가스, 군사 서비스, 수소 인프라 등 다양한 분야에서 사용되고 있다(Amez et al., 2025; Jung et al., 2022a; Kang et al., 2024; Kayacık et al., 2024; Lu et al., 2024; Malik et al., 2024; Tang et al., 2024; Tom et al., 2024; Venkatesan et al., 2024; Wu et al., 2025). 최근에는 수소 충전소 등에서 사용되는 고분자 소재의 수소 확산, 투과 및 누설의 측정과 고분자 소재의 물리적 역학적 물성 평가에 활용되고 있다(Choi et al., 2022; Fujiwara et al., 2022; Jung et al., 2020a, 2022b, 2022c, 2023a, 2023b; Jung and Lee, 2024a; Kim et al., 2022; Lee et al., 2017, 2023, 2024a, 2024b, 2024c; Menon et al., 2016; Moon et al., 2021, 2023; Profatilova et al., 2024; Su et al., 2023; Wang et al., 2022).

다양한 원리를 응용한 가스 센서들이 개발되고 있고, 각각의 장단점을 가지고 있다. 광학 분광학 가스 센서는 특정 파장에서 빛의 흡수 또는 방출을 측정하여 가스를 탐지하며, 높은 민감도와 정확도를 가진다(Xie et al., 2025; Zhang et al., 2022). 이 센서는 낮은 농도의 가스를 탐지할 수 있으며, 대부분의 간섭에 영향을 받지 않지만, 온도와 압력 같은 환경적 요인에 영향을 받을 수 있다. 특히, 적외선(infrared radiation, IR) 가스 센서는 특정 파장에서 적외선 빛의 흡수를 측정하여 가스 분자를 검출하며, 널리 활용되는 대표적인 가스 센서 중 하나이다(Meng et al., 2024; Sadovnikov et al., 2025; Schlicke et al., 2024; Yu et al., 2012). 한편, 전기화학적 가스 센서는 가스와 전극 간의 화학 반응을 통해 전류를 발생시키며, 이 전류는 가스 농도와 비례하기 때문에 이를 측정하여 가스 농도를 정량화할 수 있다(Chen et al., 2024; Cowen et al., 2024; Mishra et al., 2024; Saffell and Martin, 2024; Seleka et al., 2024). 이 센서는 높은 민감도, 낮은 전력 소비 등의 장점이 있지만, 응답시간이 수십 초로 상대적으로 길며, 전극이나 전해질의 마모로 인해 시간이 지나면서 성능이 저하될 수 있다. 반도체 가스센서는 가스 분자가 반도체 표면과 상호작용할 때 발생하는 저항의 변화를 이용하여 가스 농도를 정량화한다(Kwon et al., 2024; Li et al., 2024; Molleman et al., 2024). 이 센서는 응답 속도가 빠르고 비용이 낮다는 장점이 있지만, 환경적 요인에 매우 민감하다. 촉매 연소 가스 센서는 (Bowen, 2023; Tamura and Imanaka, 2021; Zhang et al., 2023) 촉매 산화를 통해 가스를 탐지하며, 가연성 가스에 대해 높은 민감도를 제공하지만, 독성 물질에 의해 수명에 제약을 받는다.

마지막으로, 가스크로마토그래피(gas chromatography)와 (Alinoori and Masoum, 2018; Hardoyono and Windhani, 2023; Hinojo et al., 2024; Hu et al., 2021; Huang et al., 2024; Jung et al., 2021d, 2021e, 2021f, 2022d; Slater et al., 2024) 질량 분석법은(Imonigie et al., 2006; Jung et al., 2021g; Pérès et al., 2002; Quercia et al., 2021; Shaltaeva et al., 2017; Zhu et al., 2024) 매우 정밀한 분석이 가능하지만 주로 연구 및 실험실 환경에서 사용이 국한된다. 가스 크로마토그래피는 혼합가스에서 개별 성분을 분리하고 이를 정량적으로 분석한다. 질량 분석법은 이온화된 후 질량을 기반으로 가스 분자를 식별한다. 이러한 센싱 시스템은 비싸고 정기적인 유지보수가 필요하여 실시간 현장 모니터링에는 적합하지 않는 것으로 판단된다. 다시 말하자면 기존의 가스 센싱 기술들은 정밀한 측정을 하지만 시료 크기, 민감도, 선택성 및 환경적 안정성에서 한계를 가진다. 이를 해결하기 위해 실시간 가스 모니터링에서 안전성을 보장하기 위해 소형화되고, 빠른 응답 시간과 높은 민감도, 변동하는 현장 조건에서도 안정적인 성능을 제공할 수 있는 효과적인 가스 센서가 필요하다.

이러한 한계를 극복하고 가스 센서 성능을 더욱 향상시키기 위해서는 효과적으로 가스의 실시간 자동 측정 기술이 필요하다. 본 연구에서 이러한 요구 사항을 충족할 수 있는 일반 목적 인터페이스 버스(general-purpose interface bus, GPIB)를 통해 LabView 프로그레밍 기반 컴퓨터와 연결된 웹캠을 이용하여 자체 개발한 이미지 분석 알고리즘을 이용하여 부피 측정 기반의 가스센서를 제안한다. 이는 웹캠, 눈금 실린더 및 온도, 압력 센서를 이용한 간단한 가스 측정 기술로써 확산 분석 프로그램(Jung et al., 2021h, 2022e, 2023c; Lee and Jung, 2024c)을 이용하여 가스 충전량과 확산도의 분석이 가능하다 이 휴대용 가스 센서는 대상 가스와의 화학적 상호작용 없이 즉시 가스 농도, 누출 및 확산을 효과적으로 측정할 수 있다.

본 연구에서 개발한 가스 센서를 이용하여 고압 가스 압력 용기의 O링 가스 밀봉 재료 및 라이너 재료로 사용되는 질화부타디엔고무(nitrile butadiene rubber, NBR), 에틸렌프로필렌디엔모노머(ethylene propylene diene monomer, EPDM), 고밀도 폴리에틸렌(high-density polyethylene, HDPE), 저밀도 폴리에틸렌(low-density polyethylene, LDPE) 등의 고분자 재료에서 가스의 충전량 및 확산도 측정에 활용하였다.

한편 개발된 가스 센서 시스템은 H₂, He, N₂, O₂, Ar과 같은 다양한 가스의 농도를 정량화하고 가스의 고분자 재료에서 가스 흡착과 확산 및 투과 특성을 실시간으로 측정할 수 있다. 본 연구에서 개발된 센서의 성능은 측정 감도, 분해능, 안정도, 측정 범위, 반응 시간 등의 인자들를 통해 평가하였다. 이 센서로 얻어진 고분자 시료에서의 가스 장입량과 확산도 측정결과를 다른 방법으로 얻은 결과와 추후에 상호 비교하여 유효성을 검증할 예정이다. 마지막으로 개발된 센서 기술의 특징들을 결론에 요약하였다.

2. 연구 자료 및 방법

2.1. 시료 준비 및 분석 프로그램

가스 센서를 이용한 측정용 시료는 수소 인프라에서 O링 밀봉 재료로 사용되는 고분자 소재인 NBR과 EPDM을 사용했다. 또한, 연료 전지 전기차의 IV형 용기의 라이너(liner) 재료로 사용되는 HDPE와 LDPE 시료도 가스 센서 성능 평가에 포함시켰다. 두 폴리에틸렌 고분자는 King Plastic Corporation에서 첨단 항균 기술을 적용하여 제조되었다. 고분자 시료의 배합방법과 밀도는 이전 문헌에 나와 있다(Jung et al., 2022f; Jung, 2024b). NBR과 EPDM은 각각 60°C에서 48시간 동안 열처리하여 탈가스를 진행하였다. 고분자 시료는 다음과 같은 형태와 크기로 사용되었다:

– 원통형 NBR: 반지름 약 7.0 mm, 두께 약 2.1 mm

– 원통형 EPDM: 반지름 약 7.0 mm, 두께 약 2.5 mm

– 원통형 HDPE: 반지름 약 6.5 mm, 두께 약 2.4 mm

– 원통형 LDPE: 반지름 약 6.5 mm, 두께 약 2.4 mm

고압 가스 충전을 위해 내부 지름 70 mm, 높이 120 mm인 스테인레스 스틸(Stainless steel, SUS) 316 챔버가 사용되었다. 실험에 사용된 순수 가스는 최대 12 MPa의 압력으로 저장된 고압 가스 용기에서 직접 공급되었으며, 이를 이용해 시료는 실온에서 2 MPa에서 10 MPa 범위의 압력으로 충전되었다. 사용된 순수 가스의 순도는 다음과 같다:

– H2: 99.99%, He: 99.99%, N2: 99.99%, O2: 99.99%, Ar: 99.99%

고압 챔버에 가스를 충전하기 전에 0.5–1 MPa의 압력에서 해당 가스로 세 번 퍼지하였다. 시료는 측정하고자 하는 압력에서 24~48시간 동안 가스에 충전되었다. 고압 환경에서 기체는 시료 내부로 서서히 확산 및 흡착되며, 시료의 두께가 증가할수록 흡착 평형에 도달하는 데 더 긴 시간이 소요된다. 본 연구에서 사용한 시편 크기의 경우, 최대 48시간 동안의 가스 충전은 가스 흡착의 평형 상태에 도달하기에 충분한 시간이었다. 가스에 충전된 후, 밸브를 열어 챔버 내 가스를 방출하였다. 감압 후, 고압 가스가 대기압으로 감소한 순간(t = 0)부터 경과 시간을 기록하였다.

2.2. 방출 가스의 부피 측정을 통한 가스 농도 측정 원리

고압 기체가 충전된 시료는 대기압 환경에서 시간이 경과함에 따라 가스를 서서히 방출한다. 부피 분석법(volumetric measurement method)은 이 시간 경과에 따라 방출된 가스로 인해 물이 들어있는 눈금 실린 더 내부의 수위가 감소하는 현상을 관측하여, 방출된 가스의 양을 정량적으로 분석하는 방법이다. Fig. 1은 방출된 가스의 농도를 측정하기 위해 사용된 부피 분석 장치 나타낸다. 이 장치는 가스 충전을 위한 고압 챔버와 물 탱크위에 부분적으로 잠긴 눈금 실린더로 구성된다. 챔버에서 고압 충전 후 감압을 거친 후, 시료는 Fig. 1에서 눈금 실린더 상단에 있는 가스 셀 공간에 고무 실(rubber seal)을 이용하여 가두어 놓는다. 시료에서 방출된 가스로 인해 시간이 지남에 따라 실린더 내 물의 수위가 감소하게 만든다. 그 결과, 실린더 내부의 가스 압력(P)과 부피(V)는 시간에 따라 변화한다. 실린더 내부의 가스는 이상 기체 방정식에 따르게 된다. 즉, PV=nRT. 여기서 R은 기체 상수(8.20544 × 10–5 m3·atm/(mol·K)), T는 실린더 상단에 있는 기체의 온도, n은 실린더 내에 방출된 기체 몰수이다. 눈금 실린더 내부의 가스에 대한 시간에 따른 P(t)와 V(t)는 다음과 같이 표현된다(Jung et al., 2022g, 2024c):

OGCSBN_2025_v41n2_1_277_4_f0001.png 이미지

Fig. 1. Volumetric gas measurement system using a graduated cylinder following high-pressure exposure and decompression. (a) Specimen placed in the high-pressure chamber. (b) After decompression and loading the specimen into the cylinder, gas emission is measured in the graduated cylinder partially submerged in water. Blue means distilled water.

OGCSBN_2025_v41n2_1_277_4_f0002.png 이미지

Fig. 2. Diffusion analysis program for calculating the N2 uptake and diffusion coefficient using Eq. (3).

P(t) = P0 – ρgh(t), V(t) = V0 – Vs – Vh(t)       (1)

여기서 P0는 실린더 외부의 대기압, ρ는 물통에 있는 증류수의 밀도, g는 중력 가속도, h(t)는 물통(Water container)의 수위에서 측정한 실린더 내부의 물의 수위(높이), V0는 실린더 내부의 총 부피이며 가스와 물의 부피의 합에 해당한다. 시간에 따라 변하는 Vh(t)는 눈금 실린더 내부의 물통의 수위에서부터 측정한 물의 부피이다. Vs는 시료의 부피이다.

시료에서 방출된 가스로 인해 실린더 내부의 수위가 감소한다. 이때 시간에 따른 물의 수위 Vh(t)를 측정하여 방출된 가스의 부피(Vg)를 알 수 있다. 이로부터 시료에서 방출된 단위 질량에 대한 가스 농도 [C(t)]는 아래와 같이 얻을 수 있다(Jung et al., 2022f, 2022g, 2024c).

\(\begin{align}\begin{aligned} C(t)[w t \cdot p p m]= & \frac{P_{0}}{R T_{0}}\left[V_{g}(t)+V(t)\{\beta(t)-\alpha(t)\}\right][\mathrm{mol}] \\ & \times \frac{m_{g}\left[\frac{g}{\mathrm{~mol}}\right]}{m_{\text {specimen }}[g]} \times 10^{6}, \\ \alpha & =\frac{T(t)-T_{0}}{T_{0}}, \beta=\frac{P(t)-P_{0}}{P_{0}}\end{aligned}\end{align}\)       (2)

T0와 P0는 실린더 내 가스의 초기 온도와 압력이다. α와 β는 각각 초기 온도와 압력에 대한 온도와 압력의 변화율이다. V(t)는 초기 남아있는 공기 부피(Va)와 방출된 가스 부피[Vg(t)]의 합이다. 즉, V(t) = Va + Vg(t)이다. \(\begin{align}\mathrm{m}_{\mathrm{g}}\left[\frac{\mathrm{g}}{\mathrm{mol}}\right]\end{align}\)은 가스의 몰 질량으로, 예를 들어 H2의 경우 \(\begin{align}\mathrm{m}_{\mathrm{H}_{2}}\left[\frac{\mathrm{~g}}{\mathrm{~mol}}\right]=2.016\left[\frac{\mathrm{~g}}{\mathrm{~mol}}\right]\end{align}\)이고, mspecimen은 시료의 질량이다.

식(2)에 따라 시간에 따라 변화하는 수위의 측정으로 농도 C(t)를 얻을 수 있다. C(t)는 실험실 내 온도와 압력 변화에 영향을 받는다. 정확한 측정을 위해 온도와 압력 변화에 따른 보상을 한다. 방출된 가스로 인한 가스 부피의 변화는 웹캠을 이용해 수위의 이미지의 밝기 분석을 통한 픽셀 거리 측정을 통해 얻어진다.

2.3. 가스 충전량과 확산도 추출을 위한 확산 분석 프로그램

가스 방출이 Fick의 확산 과정(Fickian diffusion process)이라고 가정하면 방출된 가스의 농도 CE(t)는 다음과 같이 계산된다(Crank, 1979; Demarez et al., 1954):

\(\begin{align}\begin{array}{l} \frac{\mathrm{C}_{\mathrm{E}}(\mathrm{t})}{\mathrm{C}_{-}}=1-\frac{32}{\pi^{2}} \times\left[\sum_{\mathrm{n}=0}^{\infty} \frac{\exp \left(\frac{-(2 \mathrm{n}+1)^{2} \pi^{2} \mathrm{Dt}}{1^{2}}\right)}{(2 \mathrm{n}+1)^{2}}\right] \times\left[\sum_{\mathrm{n}=1}^{\infty} \frac{\exp \left(-\frac{\mathrm{D} \beta_{\mathrm{n}}^{2} \mathrm{t}}{\rho^{2}}\right)}{\beta_{\mathrm{n}}^{2}}\right] \\ = 1-\frac{32}{\pi^{2}} \times\left[\frac{\exp \left(-\frac{\pi^{2} \mathrm{Dt}}{l^{2}}\right)}{1^{2}}+\frac{\exp \left(-\frac{3^{2} \pi^{2} \mathrm{Dt}}{l^{2}}\right)}{3^{2}}+\ldots,+\frac{\exp \left(-\frac{(2 \mathrm{n}+1)^{2} \pi^{2} \mathrm{Dt}}{l^{2}}\right)}{(2 \mathrm{n}+1)^{2}}+\ldots,\right] \\ \times\left[\frac{\exp \left(-\frac{\mathrm{D} \beta_{1}^{2} \mathrm{t}}{\rho^{2}}\right)}{\beta_{1}^{2}}+\frac{\exp \left(-\frac{\mathrm{D} \beta_{2}^{2} \mathrm{t}}{\rho^{2}}\right)}{\beta_{2}^{2}}+\ldots,+\frac{\exp \left(-\frac{\mathrm{D} \beta_{\mathrm{n}}^{2} \mathrm{t}}{\rho^{2}}\right)}{\beta_{\mathrm{n}}^{2}}+\ldots,\right]\end{array}\end{align}\)        (3)

여기서 βn은 제로차수 베셀 함수 J0(βn)의 근으로, β1 = 2.40483, β2 = 5.52008, β3 = 8.65373, ⋯, β50 = 156.295이다. 식(3)은 무한 급수항이 두개가 있는 것으로 원통형 형상의 시료에 대한 Fick의 두 번째 확산 방정식의 해에 해당된다. 여기서 t = 0일 때 CE = 0이고, t = ∞일 때, CE = C∞이다. C∞는 무한 시간에서의 포화 가스 농도, 즉 가스 충전량이다. D는 확산 계수이며, l과 ρ는 각각 원통형 시료의 두께와 반지름이다.

식(3)에서 두 개의 합에 몇개의 항을 포함되어야 D와 C∞를 정확하게 계산할 수 있는지를 추정하였다. 감압 후 시간이 충분히 10,000초 보다 크면, 식(3)에서 첫 번째와 두 번째 합의 세 항 정도까지가 주로 CE(t) 값에 기여한다. 그러나 t가 100초 미만일 경우, 식(3)은 빠르게 수렴하지 않기 때문에 많은 항(50개 항)을 포함해야 한다. 식(3)을 사용하여 2% 이하의 불확도로 계산하기 위해서는 두 합의 곱에서 64개 이상의 항을 포함해야 한다. 따라서 식(3)에서 첫 번째 합에 n = 100항을, 두 번째 합에 n = 50항(β50까지)을 포함하여 D와 C∞를 계산하는 전용 확산 분석 프로그램이 필요하여 이를 개발하였다. Nelder-Mead 비선형 최적화 알고리즘을(Nelder and Mead, 1965) 기반으로 개발한 확산 분석 프로그램을 적용하여, 식(3)을 사용하여 CE(t) 데이터를 분석하였다.

Fig. 3는 확산도 분석 프로그램을 이용하여 분석한 질소의 충전량(C∞)과 확산도(D)의 분석 예시를 보여준다. 왼쪽 아래에 원통형 모양의 시편의 반경(radius)과 두께(height orthickness)를 입력한 후, 오른쪽 중간에 위치한 Curve Fitting을 실행하여 오른쪽 아래에 보인 것과 같이 식(2)에서 구한 각 시간에서의 방출 질소량을 식(3)에 대입하여 자체개발한 확산 분석 프로그램을 이용하여 질소 확산계수와 질소 충전량 값을 얻을 수 있다. 그 결과로서 D = 2.515 × 10–11 m2/s, C∞ = 2,155wt·ppm의 값을 얻는다. 여기서 오른쪽 아래 값은 offset(421.3 wt·ppm) 값이며, 이것은 시간지연 동안 빠져나간 질소량(wt·ppm)을 의미한다.

OGCSBN_2025_v41n2_1_277_5_f0001.png 이미지

Fig. 3. LabVIEW Image program showing the pixel distance as a function of elapsed time in three-channel cylinders using a webcam and LabVIEW software. (a) Adjusting initial brightness and contrast values. (b) White bright spots mark the water level, with a yellow rectangle and reference line at the top. (c) Light intensity graph plotted against pixel distance from the reference, with a threshold of 14, showing a sharp increase in intensity as the water level is reached. (d) Pixel distance of the water level from the reference plotted against elapsed time in three channels.

3. 연구 결과 및 토의

3.1. 수위 측정을 위한 수위 이미지의 밝기 분석 알고리즘

시료에서 방출된 가스는 시간이 경과함에 따라 실린더 내부의 수위를 낮춘다. 본 연구에서 개발한 LabView 프로그램과 웹캠을 사용하여 수위를 측정한다. Fig. 3은 세 개의 실린더 채널에서 시간에 따라 얻은 픽셀 거리를 측정한 3개의 이미지를 보여주며, 측정은 플롯 1에 대해 흰색, 플롯 2에 대해 빨간색, 플롯 3에 대해 노란색 선으로 표시된다. 수위에 해당하는 픽셀 거리는 시간순으로 캡처된 이미지를 사용하여 다음 알고리즘을 통해 자동으로 측정된다. 각 이미지의 흰색으로 표시된 밝은 수위의 감지를 위해 사용된 알고리즘은 다음과 같다:

1) 먼저 Fig. 3(a)에서 수위 이미지를 정확히 왜곡없이 측정하기 위해 실내 조명상태를 고려하여 초기 밝기(brightness)와 대비(contrast) 값을 조정한다.

2) Fig. 3(b)에서 수위는 세 개의 실린더에서 세 개의 흰색의 밝은 점으로 표시된다. 눈금 실린더를 아래로 스캔하기 위한 초기 수직 픽셀 위치와 수평 픽셀 범위를 설정한다. 이는 노란 직사각형으로 수위에 해당하는 픽셀거리(pixel distance) 스캔하기 위한 범위에 해당된다. 또한 기준선은 노란 직사각형 상단에 해당된다.

3) Fig. 3(c)에서는 사용자가 설정한 수평 범위의 좁은 직사각형 창이 한 픽셀씩 내려가며 측정된다. 이 값은 미리 설정된 밝기의 기준값인 14와 비교하여, 평균 밝기가 기준값을 초과하는 밝은 수위에 도달할 때까지 반복된다. 이 과정은 세 개의 채널(흰색, 빨간색, 노란색 피크)에 대해 순차적으로 적용된다. Fig. 3(c)에는 세 채널에 대한 빛의 밝기 피크가 고정된 시간에서 픽셀 거리의 함수로 나타난다.

4) 마지막으로 Fig. 3(c)에서 각 시간에서 얻은 수위의 픽셀거리를 경과시간에서 플라팅(plotting)하면 세 개의 실린더(cylinder) 채널에서 측정된 경과 시간에 따른 수위에 해당하는 픽셀 거리가 Fig. 3(d)와 같이 얻어진다.

3.2. 예비 교정에 의한 가스 충전량과 확산 측정 절차

앞서 설명한 대로 측정된 수위에 해당하는 픽셀 거리는 사전 교정(pre-calibration) 식을 통해 수위변화에 해당하는 방출된 가스의 부피로 변환된다. Figs. 4(a–c)는 사전 교정을 통해 원통형 LDPE 고분자 시료에서 산소 흡수 및 확산성을 얻는 과정이다:

OGCSBN_2025_v41n2_1_277_6_f0001.png 이미지

Fig. 4. Procedure for acquiring diffusion parameters for a cylindrically shaped LDPE polymer. (a) Pre-calibration result showing the linear relationship between gas volume and pixel distance, (b) time-dependent oxygen emission volume derived from pixel distance, and (c) diffusion parameters D and C∞ calculated using a diffusion analysis program based on Eq. (3).

1) 먼저 사전 교정 데이터를 통해 관련된 식을 얻는다. 국가 표준에 소급을 받은 길이 표준을 사용하여 해당 실린더에서 픽셀거리에 따른 실린더 내부 부피를 측정한다. 실린더 내부 부피(V=πR²h)는 원통의 외부 높이(h)와 내부 반지름(R)을 측정하여 계산된다. 픽셀 거리 측정은 Fig. 3에서와 같이 프로그래밍된 웹캠에서 얻는다. 웹캠으로 측정된 픽셀거리에 따른 내부 부피 변화를 Fig. 4(a)에 서 직선의 기울기로 나타내었다. 픽셀거리와 실린더 내부 부피간의 선형 상관 관계는 완벽한 제곱 상관 계수 R² = 1.000으로 회귀 분석을 통해 얻었다.

2) 사전 교정의 선형성에 따라 방출된 산소에 의해 프로그래밍된 웹캠에서 측정된 픽셀 값은 산소 방출 부피로 변환된다(Fig. 4b). 검은색과 파란색 정사각형은 감압후 시간에 따른 각각 픽셀 단위의 산소 방출과 mL 단위의 방출된 산소가스의 부피를 나타낸다.

3) 방출된 산소가스의 부피는 식(2)를 통해 경과 시간에 따른 wt·ppm 단위의 방출된 가스로 변환된다. 마지막으로, 확산 분석 프로그램을 사용하여 식(3)을 적용함으로써 확산도 D (4.41 × 10–11 m²/s)와 가스 장입량 C∞가 결정된다. Fig. 4(c)에서 최소 제곱 적합을 기반으로 측정된 결과를 통해 최종 O₂ 농도(C∞ = 4,781 wt·ppm)를 얻으며, 시간 지연으로 인해 이미 방출된 가스량 오프셋 값이 보상된 결과이다.

한편 Fig. 5는 웹캠을 사용하여 수위의 이미지를 빛 밝기 분석을 기반으로 분석 한 가스 센서의 측정 시스템을 보여준다. Fig. 5(a)는 GPIB 인터페이스와 프로그래밍된 PC가 연결된 웹캠과 함께 방출된 가스의 부피 측정을 보여준다. Fig. 5(b)에서는 원통에 있는 시료에서 발생하는 확산 및 탈착 과정을 확대하여 가스 방출 과정을 보여준다.

OGCSBN_2025_v41n2_1_277_6_f0002.png 이미지

Fig. 5. A measuring system of the gas sensor using light intensity analysis of images captured by a webcam. (a)Volumetric gas emission measurement with graduated cylinders and a webcam interfaced with a PC via GPIB and (b) gas emission process from the specimen loaded in the cylinder.

3.3. 개발한 가스 센서의 적용 및 성능 평가

본 절에서는 우리는 개발된 웹캠 센서 시스템의 온도 압력 변화에 의한 보상방법과 보상예를 먼저 제시한다. 가스 센서를 활용한 고분자 시료의 충전량 및 확산도 측정결과와 마지막에는 성능 테스트 결과를 제시하였다.

3.3.1. 온도와 압력 변화에 의한 가스 농도의 프로그래밍 보상

식(2)에 따르면, 방출된 아르곤 가스의 질량 농도는 모두 실린더 내부의 온도와 압력에 선형적으로 의존한다. 예를 들어, 온도와 압력이 각각 3%씩 변하면 방출된 아르곤 농도에서 동일한 크기의 오차가 발생한다. 그러나 우리는 자동 프로그래밍 보상을 통해 온도와 압력 변화로 인한 아르곤 농도의 오차를 줄일 수 있다. 식(2)의 V(t)(β–α) 항은 온도와 압력 변화에 의해 보상된 아르곤 부피를 나타낸다. Fig. 6은 온도와 압력 변화에 대한 대표적인 자동 보상 과정을 보여준다. 이 보상은 컴퓨터와 연결된 온도 및 압력 센서를 통해 자동으로 가능하다.

OGCSBN_2025_v41n2_1_277_7_f0001.png 이미지

Fig. 6. Programmable compensations for fluctuation in both temperature and pressure at 9 MPa forLDPE. (a) Change rates of the temperature and pressure with regard to time after decompression. Both the temperature and pressure are automatically measured and recorded. (b) Uncompensated and compensated argon gas volume versus time after decompression. (c) Compensated argon volume and emission content versus time after decompression. These values coincide with each other by multiplying k.

Fig. 6(a)는 시간에 따른 온도와 압력의 변화율(α와 β)을 표시한 것이다. 보상되지 않은 아르곤 부피와 보상된 아르곤 부피는 각각 온도/압력 변화에 대한 보상 전과 보상 후를 나타낸다(Fig. 6b 참조). Fig. 6(b)의 아래쪽 파란색 영역은 보상된 아르곤 부피, V(β – α)를 의미한다. 위쪽 방향으로의 보상은 Fig. 6(b)에서 검은색 데이터로 해당된다.

마지막으로, Fig. 6(c)는 질량 농도 단위(wt·ppm)로 표시된 아르곤 방출 농도가 식(3)에서 비율 k = [mg/mspecimen]을 통해 보상된 아르곤 부피와 동일함을 보여준다. Fig. 6(c)의 삽입된 부분에서 보정된 아르곤 부피와 방출 내용 간의 거의 제로 차이는 이 결과를 뒷받침한다.

3.3.2. 고분자에서 가스 확산 결과

고압에서 4종의 가스로 충전된 고분자 시편을 감압한 후, 방출된 가스의 농도와 확산 계수를 Fig. 7의 개발한 웹캠가스센서를 이용해 측정하였다. Fig. 7는 원통형 HDPE, LDPE, EPDM 에서 네 가지 가스에 대해 수위측정을 통해 얻은 측정값과 분석 결과를 보여준다. Figs. 7(a–d)의 왼쪽 그림은 수위 측정을 통해 얻은 방출 가스의 부피(파란색 채운 원)를 나타낸다. 오른쪽 그림은 방출된 가스 데이터(검은색 열린 사각형)를 보여준다. 확산 계수(D)와 최종 가스 흡수량(C∞)은 식(3)을 이용한 분석 프로그램을 통해 도출되었다. 오른쪽 그래프의 파란색 선은 식(3)을 이용한 분석 결과이며, 최종 가스 충전량(C∞)은 파란색 화살표로 표시되었다. Figs. 7(a-d)에서 볼 수 있듯이, 모든 시료 내 모든 가스에서 시간에 따른 단일 모드 가스 방출 거동이 관찰되었다. 시료에서 나타나는 단일 모드 가스 방출은 비정질 상(amorphous phase) 내 가스 확산에 의해 발생하는 것으로 해석된다.

OGCSBN_2025_v41n2_1_277_8_f0001.png 이미지

Fig. 7. Gas uptake and diffusivity determined from four gases in cylindrical HDPE, LDPE, and EPDM specimens by volumetric measurement using an image processing algorithm and a webcam. (a–d) Measured gas volume (blue filled circle) transformed from the measured water level and emitted gas emission (black open square) transferred from measured gas volume in units of wt·ppm. The blue line represents the fitted result using Eq. (3). Diffusivity parameters, D, are calculated by an analysis program based on Eq. (3). The blue line represents the fitted data using Eq. (3), with gas diffusivity, the total gas uptake marked by a blue arrow. Here, R is the radius of the cylindrical specimen. T is the thickness of the cylindrical specimen.

3.3.3. 가스 센서의 성능 평가

내부 지름(D)을 가진 실린더(D = 8.0 mm)로 가스 센서의 다양한 성능 수준을 평가하였다. 성능 평가 항목은 측정 감도(sensitivity), 분해능(resolution), 안정도(stability), 측정 범위(measuring range), 응답 시간(response time), 성능 지수(figure of merit, FOM) 및 제곱 상관 계수(squared correlation coefficients, R²)가 포함된다(Table 1). 웹캠 센서의 측정 감도는 픽셀 거리 변화에 따른 가스 부피의 변화로 정의되며, 이는 미리 보정한 값을 통해 측정된다. Fig. 3(a)의 직선 기울기는 내부 지름이 8.0 mm인 실린더의 감도를 나타낸다. 두 실린더에 대한 감도 값은 각각 D = 8.0 mm일 때 0.021 mL/px 이다.

Table 1. Performance tests of webcam gas sensing systems using graduated cylinders

OGCSBN_2025_v41n2_1_277_8_t0001.png 이미지

가스 센서의 분해능은 일반적으로 측정 감도의 역수로 간주된다. 따라서 측정 감도가 높은 센서는 더 나은 분해능을 의미한다. 분해능은 웹캠의 한 픽셀 측정값에서 계산된 질량 농도를 나타내며, 표 1에서 감도 결과에 따르면 D1 = 8.0 mm의 실린더에 대한 최소 내부 부피는 각각 0.021 mL로, 이에 해당하는 질량 농도는 각각 1.0 wt·ppm이다. 분해능 값(1.0 wt·ppm)은 각각 2.0 g의 무게와 14.0 mm의 지름, 2.2 mm의 두께를 가진 NBR 시료를 기준으로 계산하였다. 분해능은 시료의 수(또는 시료 질량)를 늘리거나 내부 지름이 더 작은 실린더를 사용함으로써 1.0 wt·ppm 이하로 할 수 있다.

웹캠 센서 시스템의 안정도는 가스 방출 측정이 완료된 후 24시간 동안 측정하여 얻은 표준 편차로 정의되며, 질량 농도에 대해 0.3%로 얻었다. 실험실 환경에서 최대 168시간 동안의 장기 측정에서도 안정성이 유지되었기 때문에, 본 연구에서는 24시간 측정을 단기 안정성을 평가하는 대표적인 지표로 제시하였다. 측정 감도와 해상도 결과를 바탕으로 실린더에 대해 최소 부피에 대한 해상도는 1 wt·ppm/0.021 mL로 얻어졌다. 한편, 측정 범위는 실린더의 체적 용량에 따라 최대 허용 농도를 나타내며, 실린더의 체적 용량은 20 mL 이다. Table 1에 나오는 최대 측정 용량인 약 1000 wt·ppm은 21 mL 용량에 해당한다. 측정 범위는 시료 질량과 실린더의 체적 용량을 변경하여 조정할 수 있다.

웹캠 이미지에서 얻은 응답은 1초 이내에 즉시 반응한다. FOM는 측정된 데이터와 식(3) 간의 표준 편차를 나타낸다. 센서 시스템에서 FOM 값이 0.9 % 이고, 측정값과 식(3)의 이론값과의 좋은 일치를 보인다. R²은 미리 보정한 값을 바탕으로 픽셀 거리와 가스 부피 간의 제곱 상관 계수이다. R² 값이 1.00이면 픽셀거리와 방출된 가스 부피 간에 완벽한 선형 관계가 있음을 나타낸다. 개발된 가스 센서의 성능 평가 결과는 다시 표 1에 요약되어 있다. 실험 목적에 맞는 적절한 센서를 선택할 수 있도록 실린더의 체적 용량, 시료 수 및 감도를 변경하여 측정 범위, 분해능 및 감도를 조정할 수 있다.

4. 결론

이번 연구에서 웹캠을 이용한 수위의 이미지 분석 알고리즘과 LabView 프로그램을 활용한 가스 센서를 개발하였다. 이는 충전 시료에서 방출되는 가스가 실린더 내부의 수위 감소를 야기하여, 이로 인한 방출 가스의 부피 분석을 기반으로 한 가스 센서이다. 고분자 시료에서 방출된 가스로 인한 물의 수위 변화는 웹캠 센서를 통한 수위의 밝기를 픽셀 거리의 단위로 실시간으로 추적하여 시간에 따른 가스의 농도의 변화량으로 환산하여, 그 결과를 확산 분석 프로그램을 통해 분석하면 가스로 충전한 고분자 시료의 가스 충전량과 확산도를 얻는 방법이다. 이 개발된 가스 센서는 가스 누출을 감지할 수 있고 방출된 가스의 농도, 용해도, 확산도 및 투과도를 얻을 수 있다. 이 가스센싱 시스템은 H₂, He, N₂, O₂, Ar과 같은 다양한 가스의 농도를 정량화하고, 나아가 가스의 고분자 재료에서 가스 흡착과 확산 및 투과 특성을 효과적으로 규명 할 수 있다고 판단된다.

본 연구에서 개발된 센서의 성능은 측정 감도, 분해능, 안정성, 측정 범위, 반응 시간 등을 통해 센서의 성능을 평가하였다. 개발한 센서는 다음과 같은 주요 성능을 가진다: 1.0 wt·ppm 가스 농도의 검출 분해능, 최대 1,000 wt·ppm의 측정 범위, 0.3 %의 안정성, 1초 이내의 빠른 응답 시간을 가진다. 온도와 압력 변화에 무관한 이 센서는 현장에서 가스를 실시간 모니터링하고 측정하는 데 사용될 수 있고, 개발된 센서 기술의 장점은 다음과 같다:

(1)고분자 재료의 가스 침투 및 확산을 측정하는 효율적인 센싱기술

(2) 시료 크기, 형상 및 가스 종류에 관계없이 적용가능하고 온도/압력 변화에 영향을 받지 않음

(3) 전용 확산 분석 프로그램을 적용하여 가스 충전량과 확산도를 정확히 분석할 수 있는 기술

(4) 가스의 농도 측정 범위, 해상도 및 측정 감도를 조정할 수 있는 유연한 기술

(5) 가스 방출 및 누출 과정이 물의 수위 변화를 통해 즉시 모니터링되는 가시적인 기술

(6) 해당 가스 분자와 센서 간의 화학 반응 없이 독립적으로 작동하는 센싱 기술

본 연구에서 개발한 센서는 소형화 할 수 있고 휴대가 가능하다. 이 센서는 수소 충전소 등의 수소 인프라 지역의 안전 관리뿐만 아니라 가스 산업에서 가스 환경 모니터링에도 적용이 가능하다. 또한 개발된 가스 센싱 방법은 고압 조건에서 O링의 투과 특성, 누출 및 밀폐 성능 등의 평가가 가능하므로 앞으로 현장에서 활용 가능성은 많다고 사료된다.

사사

본 논문은 2025년도 한국표준과학연구원의 수소융복합스테이션 신뢰성 측정표준 기술개발 재원으로 지원을 받아 수행된 연구임(한국표준과학연구원-2025-GP2025-0007).

Conflict of Interest

No potential conflict of interest relevant to this article was reported.

References

  1. Alinoori, A. H., and Masoum, S., 2018. Multicapillary gas chromatography - Temperature modulated metal oxide semiconductor sensors array detector for monitoring of volatile organic compounds in closed atmosphere using Gaussian apodization factor analysis. Analytical Chemistry, 90(11), 6635–6642. https://doi.org/10.1021/acs.analchem.8b00426
  2. Amez,I.,Castells,B., León,D., and Paredes,R., 2025. Study of quaternary hydrogen and biogas mixtures: An industrial safety approach. Fuel, 381, 133663. https://doi.org/10.1016/j.fuel.2024.133663
  3. Bowen, W., 2023. Research on nonlinear calibration of mine catalytic-combustion-based combustible-gas sensor based on RBF neural network. Heliyon, 9(3), e14055. https://doi.org/10.1016/j.heliyon.2023.e14055
  4. Chen, W., Liao, D., and Wu, S., 2024. Study on the mechanism of temperature effect on SO2 electrochemical gassensor. Journal of the Electrochemical Society, 171(11), 117519. https://doi.org/10.1149/1945-7111/ad8f67
  5. Choi, B. L., Jung, J. K., Baek, U. B., and Choi, B. H., 2022. Effect of functional fillers on tribological characteristics of acrylonitrile butadiene rubber after high-pressure hydrogen exposures. Polymers, 14(5), 861. https://doi.org/10.3390/polym14050861
  6. Cowen, T., Grammatikos, S., and Cheffena, M., 2024. Molecularly imprinted polymer nanoparticle-carbon nanotube composite electrochemical gas sensor for highly selective and sensitive detection of methanol vapour. Analyst, 149(8), 2428–2435. https://doi.org/10.1039/D4AN00045E
  7. Crank, J., 1979. The mathematics of diffusion. Oxford University Press. 
  8. Demarez, A., Hock, A. G., and Meunier, F. A., 1954. Diffusion of hydrogen in mild steel. Acta Metallurgica, 2, 214–223. https://doi.org/10.1016/0001-6160(54)90162-5
  9. Fujiwara,H.,Ono,H.,Onoue,K., andNishimura, S., 2022.High-pressure gaseous hydrogen permeation test method-Property of polymeric materials for high-pressure hydrogen devices(1)-. International Journal of Hydrogen Energy, 45(53), 29082–29094. https://doi.org/10.1016/j.ijhydene.2020.07.215
  10. Hardoyono, F., and Windhani, K., 2023. Combination of metal oxide semiconductor gas sensor array and solid-phase microextraction gas chromatography–mass spectrometry for odour classification of brewed coffee. Flavour and Fragrance Journal, 38(6), 451–463. https://doi.org/10.1002/ffj.3759
  11. Hinojo, A., Lujan, E., Abella, J., and Colominas, S., 2024. Development and characterization of electrochemical hydrogen sensors using different fabrication techniques. Fusion Engineering and Design, 204, 114483. https://doi.org/10.1016/j.fusengdes.2024.114483
  12. Hu, J., Qu, H., Pang, W., and Duan, X., 2021. In-line detection with microfluidic bulk acoustic wave resonator gas sensor for gas chromatography. Sensors, 21(20), 6800. https://doi.org/10.3390/s21206800
  13. Huang, Z., Yang, W., Zhang, Y., Wang, P., and Wan, H., 2024. Miniaturized electrochemical gas sensor with a functional nanocomposite and thin ionic liquid interface for highly sensitive and rapid detection of hydrogen.Analytical Chemistry, 96(45), 17960–17968. https://doi.org/10.1021/acs.analchem.4c02561
  14. Imonigie,J.A.,Walters, R. N., and Gribb, M. M., 2006. Rapid isothermal gas chromatography-mass spectrometry method for validating a small ion mobility spectrometer sensor. Instrumentation Science and Technology, 34(6), 677–695. https://doi.org/10.1080/10739140600964010
  15. Jung, J. K., 2024b. Review of developed methods for measuring gas uptake and diffusivity in polymers enriched by pure gas under high pressure. Polymers, 16(5), 723. https://doi.org/10.3390/polym16050723
  16. Jung, J. K., Baek, U. B., Lee, S. H., Choi, M. C., and Bae, J. W., 2023b. Hydrogen gas permeation in peroxide-crosslinked ethylene propylene diene monomer polymer composites with carbon black and silica fillers. Journal of Polymer Science, 61(6), 460–471. https://doi.org/10.1002/pol.20220494
  17. Jung, J. K., Kim, I. G., Chung, K. S., and Baek, U. B., 2021a. Analyses of permeation characteristics of hydrogen in nitrile butadiene rubber using gas chromatography. Materials Chemistry and Physics, 267, 124653. https://doi.org/10.1016/j.matchemphys.2021.124653
  18. Jung, J. K., Kim, I. G., Chung, K. S., and Baek, U. B., 2021e. Gas chromatography techniques to evaluate the hydrogen permeation characteristics in rubber: Ethylene propylene diene monomer. Scientific Reports, 11, 4859. https://doi.org/10.1038/s41598-021-83692-1
  19. Jung, J. K., Kim, I. G., Chung, K. S., Kim, Y. I., and Kim, D. H., 2021d. Determination of permeation properties of hydrogen gas in sealing rubbers using thermal desorption analysis gas chromatography. Scientific Reports, 11, 17092. https://doi.org/10.1038/s41598-021-96266-y
  20. Jung,J.K.,Kim,I. G.,Jeon, S.K., andChung,K. S., 2021g.Characterizing the hydrogen transport properties of rubbery polymers by gravimetric analysis. Rubber Chemistry and Technology, 94(4), 688–703. https://doi.org/10.5254/rct.21.79880
  21. Jung, J. K., Kim, I. G., Jeon, S. K., Kim, K. T., Baek, U. B., and Nahm, S. H., 2021h. Volumetric analysis technique for analyzing the transport properties of hydrogen gas in cylindrical-shaped rubbery polymers. Polymer Testing, 99, 107147. https://doi.org/10.1016/j.polymertesting.2021.107147
  22. Jung, J. K., Kim, I. G., and Kim, K. T., 2021b. Evaluation of hydrogen permeation characteristics in rubbery polymers.Current Applied Physics, 21, 43–49. https://doi.org/10.1016/j.cap.2020.10.003
  23. Jung, J. K., Kim, I. G., Kim, K. T., Baek, U. B., and Nahm, S. H., 2021c. Novel volumetric analysis technique for characterizing the solubility and diffusivity of hydrogen in rubbers.Current Applied Physics, 26, 9–15. https://doi.org/10.1016/j.cap.2021.03.005
  24. Jung, J. K., Kim, I. G., Kim, K. T., Ryu, K. S., and Chung, K. S., 2021f. Evaluation techniques of hydrogen permeation in sealing rubber materials. Polymer Testing, 93, 107016. https://doi.org/10.1016/j.polymertesting.2020.107016
  25. Jung, J. K., Kim, K. T., and Baek, U. B., 2022e. Simultaneous three-channel measurements of hydrogen diffusion with light intensity analysis of images by employing webcam. Current Applied Physics, 37, 19–26. https://doi.org/10.1016/j.cap.2022.02.005
  26. Jung, J. K., Kim, K. T., Baek, U. B., and Nahm, S. H., 2022f. Volume dependence of hydrogen diffusion for sorption and desorption processes in cylindrical-shaped polymers. Polymers, 14(4), 756. https://doi.org/10.3390/polym14040756
  27. Jung,J.K.,Kim,K.T., and Chung,K. S., 2022d.Two volumetric techniques for determining the transport properties of hydrogen gas in polymer. Materials Chemistry and Physics, 276, 125364. https://doi.org/10.1016/j.matchemphys.2021.125364
  28. Jung,J.K.,Kim,K. T.,Chung, N.K., Baek, U. B., and Nahm, S. H., 2022a. Characterizing the diffusion property of hydrogen sorption and desorption processes in several spherical-shaped polymers. Polymers, 14(7), 1468. https://doi.org/10.3390/polym14071468
  29. Jung, J. K., Lee, C. H., Baek, U. B., Choi, M. C., and Bae, J. W., 2022c. Filler influence on H2 permeation propertiesin sulfur-crosslinked ethylene propylene diene monomer polymers blended with different concentrations of carbon black and silica fillers. Polymers, 14(3), 592. https://doi.org/10.3390/polym14030592
  30. Jung, J. K., Lee, C. H., Son, M. S., Lee, J. H., Baek, U. B., Chung, K. S., et al., 2022g. Filler effects on H2 diffusion behavior in nitrile butadiene rubber blended with carbon black and silica fillers of different concentrations. Polymers, 14(4), 700. https://doi.org/10.3390/polym14040700
  31. Jung,J.K., and Lee,J. H., 2024a. High-performance hydrogen gas sensor system based on transparent coaxial cylinder capacitive electrodes and a volumetric analysis technique. Scientific Reports, 14, 1967. https://doi.org/10.1038/s41598-024-52168-3
  32. Jung, J. K., Lee, J. H., Jang, J. S., Chun, N. K., Park, C. Y., Baek, U. B., et al., 2022b. Characterization technique of gases permeation properties in polymers: H2, He, N2, and Ar gas. Scientific Reports, 12, 3328. https://doi.org/10.1038/s41598-022-07321-1
  33. Jung, J. K., Lee, J. H., Jeon, S. K., Bae, J. W., and Moon, W. J., 2023c. Correlations between H2 permeation and physical/mechanical properties in ethylene propylene diene monomer polymers blended with carbon black and silica fillers. International Journal of Molecular Sciences, 24(3), 2865. https://doi.org/10.3390/ijms24032865
  34. Jung, J. K., Lee, J. H., Jeon, S. K., Baek, U. B., Lee, S. H., Lee, C. H., et al., 2023a. H2 uptake and diffusion characteristics in sulfur-crosslinked ethylene propylene diene monomer polymer composites with carbon black and silica fillers after high-pressure hydrogen exposure reaching 90 MPa. Polymers, 15(1), 162. https://doi.org/10.3390/polym15010162
  35. Jung,J.K., Lee,J. H.,Kim, Y.W., and Chung, N.K., 2024c. Development of portable gas sensing system for measuring gas emission concentration and diffusivity using commercial manometric sensors in gas exposed polymers: Application to pure gases, H2, He, N2, O2, and Ar. Sensors and Actuators B: Chemical, 418, 136240. https://doi.org/10.1016/j.snb.2024.136240
  36. Jung, J. K., Moon, Y. I., Chung, K. S., and Kim, K. T., 2020a. Development of a program for analyzing dielectric relaxation and its application to polymers: Nitrile butadiene rubber. Macromolecular Research, 28, 596–604. https://doi.org/10.1007/s13233-020-8080-6
  37. Kang, H., Bae, J., Lee, J., Yun, Y., Jeon, S., Chung, N., et al., 2024. The synergistic effect of carbon black/carbon nanotube hybrid fillers on the physical and mechanical properties of EPDM composites after exposure to high-pressure hydrogen gas. Polymers, 16(8), 1065. https://doi.org/10.3390/polym16081065
  38. Kang, H. M., Choi, M. C., Lee, J. H., Yun, Y. M., Jang, J. S., Chung, N. K., et al., 2022. Effect of the high-pressure hydrogen gas exposure in the silica-filled EPDM sealing composites with different silica content. Polymers, 14(6), 1151. https://doi.org/10.3390/polym14061151
  39. Kayacık, S. E., Schrotenboer, A. H., Ursavas, E., and Vis, I. F. A., 2024. Towards low-carbon power networks: Optimal location and sizing of renewable energy sources and hydrogen storage. Sustainable Energy, Grids and Networks, 38, 101394. https://doi.org/10.1016/j.segan.2024.101394
  40. Kim, G. H., Moon, Y. I., Jung, J. K., Choi, M. C., and Bae, J. W., 2022. Influence of carbon black and silica fillers with different concentrations on dielectric relaxation in nitrile butadiene rubber investigated by impedance spectroscopy. Polymers, 14(1), 155. https://doi.org/10.3390/polym14010155
  41. Kwon, S.-K.,Kim,J.-N., Byun, H.-G., and Kim, H.-J., 2024. Low-power and cost-effective readout circuit design for compact semiconductor gas sensor systems. Electrochemistry Communications, 169, 107834. https://doi.org/10.1016/j.elecom.2024.107834
  42. Lee, C. H., Jung, J. K., Jeon, S. K., Ryu, K. S., and Baek, U. B., 2017. Nuclear magnetic resonance study of O-ring polymer exposed to high-pressure hydrogen.Journal of Magnetics, 22(3), 478–482. https://doi.org/10.4283/JMAG.2017.22.3.478
  43. Lee, C. H., Jung, J. K., Kim, K. S., and Kim, C. J., 2024. Hierarchical channel morphology in O-rings after two cycling exposures to 70 MPa hydrogen gas: A case study of sealing failure. Scientific Reports, 14, 5319. https://doi.org/10.1038/s41598-024-55101-w
  44. Lee, J. H., and Jung, J. K., 2024c. Development of image-based water level sensor with high-resolution and low-cost using image processing algorithm: Application to outgassing measurements from gas-enriched polymer. Sensors, 24(23), 7699. https://doi.org/10.3390/s24237699
  45. Lee, J. H., Kim, Y. W., Chung, N. K., Kang, H. M., Moon, W. J., Choi, M. C., et al., 2024b. Multiphase modeling of pressure-dependent hydrogen diffusivity in fractal porousstructures of acrylonitrile butadiene rubber-carbon black compositeswith different fillers. Polymer, 311, 127552. https://doi.org/10.1016/j.polymer.2024.127552
  46. Lee, J. H., Kim, Y. W., and Jung, J. K., 2023. Investigation of the gas permeation properties using the volumetric analysis technique for polyethylene materials enriched with pure gases under high pressure: H2, He, N2, O2, and Ar. Polymers, 15(19), 4019. https://doi.org/10.3390/polym15194019
  47. Lee, J. H., Kim, Y. W., Kim, D. J., Chung, N. K., and Jung, J. K., 2024a. Comparison of two methods for measuring the temperature dependence of H2 permeation parameters in nitrile butadiene rubber polymer composites blended with fillers: The volumetric analysis method and the differential pressure method. Polymers, 16(2), 280. https://doi.org/10.3390/polym16020280
  48. Li, J., Li, Y., and Zeng, W., 2024. Gas sensing technology as the key to safety warning of lithium-ion battery: Recent advance. Sensors and Actuators A: Physical, 365, 114890. https://doi.org/10.1016/j.sna.2023.114890
  49. Li,Y.,Yuan,Z.,Ji,H.,Meng,F., and Wang,H., 2024. Response surface method analysis of gas-sensitive properties: Investigating the influence of external environment on the performance of semiconductor gas sensors. IEEE Transactions on Industrial Electronics, 71(9), 11661–11670. https://doi.org/10.1109/TIE.2023.3329254
  50. Lu, J. -N., Huang, Y., Xia, Y. -S., Dong, L. -Z., Zhang, L., Liu, J. -J., et al., 2024. Selective photosynthesis of Z-olefins through crystalline metal–organic cage-initiated expeditious cascade reactions. Carbon Energy, 6(3), e396. https://doi.org/10.1002/cey2.396
  51. Malik, A. A., Rusli, R., Nazir, S., Wong, R. H., and Arshad, U., 2024. Grid-based assessment of hydrogen leakages for an offshore process to improve the design and human performance. Process Safety Progress, 43(S1), S35–S49. https://doi.org/10.1002/prs.12567
  52. Meng, J., Balendhran, S., Sabri, Y., Bhargava, S.K., and Crozier, K.B., 2024. Smart mid-infrared metasurface microspectrometer gas sensing system. Microsystems and Nanoengineering, 10(1), 74. https://doi.org/10.1038/s41378-024-00697-2
  53. Menon, N. C., Kruizenga, A. M., Alvine, K. J., San Marchi, C., Nissen, A., and Brooks, K., 2016. Behaviour of polymers in high-pressure environments as applicable to the hydrogen infrastructure. In Proceedings of the 2016 ASME Pressure Vessels and Piping Conference, Vancouver, British Columbia, Canada, July 17–21, p. V06BT06A037. https://doi.org/10.1115/PVP2016-63713
  54. Mishra, S.R.,Gadore,V., and Ahmaruzzaman,M., 2024.Recent advances in In₂S₃-based nanocomposites for gas and electrochemical sensors: Mechanisms and developments. Materials Letters, 359, 135946. https://doi.org/10.1016/j.matlet.2024.135946
  55. Mohapatra, P., Panigrahi, S., and Amamcharla, J., 2015. Evaluation of a commercial electronic nose system coupled with universal gas sensing chamber for sensing indicator compounds associated with meatsafety. Journal of Food Measurement and Characterization, 9(2), 121–129. https://doi.org/10.1007/s11694-014-9200-9
  56. Molleman, B., Alessi, E., Passaniti, F., and Daly, K., 2024. Evaluation of the applicability of a metal oxide semiconductor gas sensor for methane emissions from agriculture. Information Processing in Agriculture, 11(4), 573–580. https://doi.org/10.1016/j.inpa.2023.11.001
  57. Moon, Y.I.,Jung,J.K.,Kim, G. H., and Chung,K. S., 2021. Observation of the relaxation process in fluoroelastomers by dielectric relaxation spectroscopy. Physica B: Condensed Matter, 608, 412870. https://doi.org/10.1016/j.physb.2021.412870
  58. Moon, Y. I., Lee, H., Jung, J., and Han, H., 2023. Direct visualization of carbon black aggregates in nitrile butadiene rubber by THz near-field microscope. Scientific Reports, 13, 7846. https://doi.org/10.1038/s41598-023-34565-2
  59. Murthy, H., 2024. Inkjet printing of MOx-based heterostructures for gas sensing and safety applications—Recent trends, challenges, and future scope. In Complex and Composite Metal Oxides for Gas, VOC and Humidity Sensors, Volume 2: Technology and New Trends (pp. 133–157).
  60. Nelder, J. A., and Mead, R., 1965. A simplex method for function minimization. Computer Journal, 7, 308–313. https://doi.org/10.1093/comjnl/7.4.308
  61. Pérès,C., Begnaud, F., and Berdagué,J.-L., 2002. Standard gas addition: A calibration method for handling temporal drifts of mass spectrometry-based sensors. Analytical Chemistry, 74(10), 2279–2283. https://doi.org/10.1021/ac0111558
  62. Profatilova, I., Fouda-Onana, F., Heitzmann, M., Bacquart, T., Morris, A., Warren, J., et al., 2024. Detrimental impact of trace amount of tetrachlorohexafluorobutane impurity in hydrogen on PEM fuel cell performance. International Journal of Hydrogen Energy, 65, 837–843. https://doi.org/10.1016/j.ijhydene.2024.04.055
  63. E., et al., 2021. Optimization of gas sensors measurements by dynamic headspace analysis supported by simultaneous direct injection massspectrometry. Sensors and Actuators B: Chemical, 347, 130580. https://doi.org/10.1016/j.snb.2021.130580
  64. Sadovnikov, S. A., Yakovlev, S. V., Kravtsova, N. S., Romanovskii, O. A., and Tuzhilkin, D. A., 2025. Dual-channel infrared OPO lidar optical system for remote sensing of greenhouse gases in the atmosphere: Design and characteristics. Sensors International, 6, 100307. https://doi.org/10.1016/j.sintl.2024.100307
  65. Saffell, J. R., and Martin, N. A., 2024. Measurements of the limit of detection for electrochemical gas sensors. Journal of Testing and Evaluation, 52(5). https://doi.org/10.1520/JTE20230675
  66. Schlicke, H., Maletz, R., Dornack, C., and Fery, A., 2024. Plasmonic particle integration into near-infrared photodetectors and photoactivated gas sensors: Toward sustainable next-generation ubiquitous sensing. Small, 20(48), 2403502. https://doi.org/10.1002/smll.202403502
  67. Seleka,W.M.,Ramohlola,K.E.,Modibane,K.D., and Makhado,E., 2024. Conductive chitosan/polyaniline hydrogel: A gas sensor for room-temperature electrochemical hydrogen sensing. International Journal of Hydrogen Energy, 68, 940–954. https://doi.org/10.1016/j.ijhydene.2024.04.240
  68. Shaltaeva,Y.R.,Podlepetsky,B.I., andPershenkov,V. S., 2017. Detection of gastraces using semiconductor sensors, ion mobility spectrometry, and mass spectrometry. European Journal of Mass Spectrometry, 23(4), 217–224. https://doi.org/10.1177/146906671772079
  69. Slater, R., Tharmaratnam,K., Belnour, S.,Auth, M.K.-H., Muhammed, R., Spray, C., et al., 2024. Gas chromatography–sensor system aids diagnosis of inflammatory bowel disease, and separates Crohn's from ulcerative colitis, in children. Sensors, 24(15), 5079. https://doi.org/10.3390/s24155079
  70. Su, Z., Zhang, W., Abdulwahab, A., Deifalla, A., and Taghavi, M., 2023. Comparison of gasoline and hydrogen pathways in order to reduce the environmental hazards of a solar-hydrogen refueling station: Evaluation based on life cycle cost and Well-To-Wheel models. Process Safety and Environmental Protection, 173, 317–331. https://doi.org/10.1016/j.psep.2023.03.015
  71. Tamura, S., and Imanaka, N., 2021. Low-temperature operable catalytic combustion-type CO gas sensors. Bunseki Kagaku, 70(6), 327–334. https://doi.org/10.2116/bunsekikagaku.70.327
  72. Tang, M., Qin,C., Sun,X., Li, M.,Wang,Y.,Cao,J., et al. 2024. Enhanced H2 gas sensing performances by Pd-loaded In2O3 microspheres. Applied Physics A: Materials Science and Processing, 130(10), 741. https://doi.org/10.1007/s00339-024-07905-w
  73. Tom, A., Singh, D. K., Shaw, V. K., Abhijith, P. V., Sajana, S., Kirandas, P. S., et al., 2024. Feedback-based gas sensing setup for ppb to ppm level sensing. Review of Scientific Instruments, 95(8), 085003. https://doi.org/10.1063/5.0202940
  74. Venkatesan, R., Harun, R., Mohamed Yusoff, H., and Abdul Razak, M., 2024. Hydrogen safety effect calculation (dispersion and thermal radiation effects) for determination of siting and safe distance. Process Safety Progress, 43(S1), S161–S169. https://doi.org/10.1002/prs.12590
  75. Wang,Y., Pang,Y.,Xu, H., Martinez,A., and Chen,K. S., 2022. PEM fuel cell and electrolysis celltechnologies and hydrogen infrastructure development - A review. Energy and Environmental Science, 15(6), 2288–2328. https://doi.org/10.1039/D2EE00790H
  76. Wang, Z., Zhu, L., Zhang, J., Wang, J., Cui, X., Chen, X., et al., 2024. ZIF-8 loaded Ag/ZnO electrospun nanofibers enabling high-performance H2 gas sensing for battery safety early warning. Sensors and Actuators B: Chemical, 418, 136276. https://doi.org/10.1016/j.snb.2024.136276
  77. Wu, M., Bai, L., Deng, F., He, J., Song, K., and Li, H., 2025. Organic-inorganic hybrid materials for catalytic transfer hydrogenation of biomass-derived carbonyl-containing compounds.Coordination Chemistry Reviews, 523, 216259. https://doi.org/10.1016/j.ccr.2024.216259
  78. Xie,R., Guan, S., andTan,Z., 2025.A gas sensor scheme for CO based on optical-feedback linear-cavity enhanced absorption spectroscopy. Optics Communications, 574, 131105. https://doi.org/10.1016/j.optcom.2024.131105
  79. Yang, Y., Zheng, S., Fu, X., and Zhang, H., 2018. Remote and portable mechanoluminescence sensing system based on a SrAl2O4:Eu, Dy film and its potential application to monitoring the safety of gas pipelines. Optik, 158, 602–609. https://doi.org/10.1016/j.ijleo.2017.12.151
  80. Yu, X. L., Li, F., Chen, L. H., and Chang, X. Y., 2012. A compact sensor based on near infrared absorption spectroscopy for flow diagnostics in a low-density hydrogen and oxygen combustion driven shock tube. Lasers in Engineering, 23(1-2), 1–17.
  81. Zhang, X., Ojha, B., Bichlmaier, H., Hartmann,I., andKohler, H., 2023. Extensive gaseous emissions reduction of firewood-fueled low power fireplaces by a gas sensor based advanced combustion airflow control system and catalytic post-oxidation. Sensors, 23(10), 4679. https://doi.org/10.3390/s23104679
  82. Zhang, Y., Wang, M., Yu, P., and Liu, Z., 2022. Optical gas-cell dynamic adsorption in a photoacoustic spectroscopy-based SOF2 and SO2F₂ gassensor. Sensors, 22(20), 7949. https://doi.org/10.3390/s22207949
  83. Zhu, X., Ahmed, W., Schmidt, K., Fowler, S.J., and Blanford, C.F., 2024. Validation of an electronic VOC sensor against gas chromatography–Mass spectrometry. IEEE Transactions on Instrumentation and Measurement, 1, 99. https://doi.org/10.1109/TIM.2024.3485428