Abstract
Purpose: Adequate definition of the skin-outside margin is essential in breast intensity-modulated radiation therapy (IMRT) to compensate for respiratory motion, anatomical deformation, and daily setup uncertainty. However, achieving a reliable external margin in air remains challenging during fluence-map optimization. This study evaluates two clinically applicable external-margin generation strategies-manual fluence extension and virtual planning target volume (PTV) expansion-and compares them with a conventional no-margin IMRT approach to assess their robustness under setup uncertainty. Methods: IMRT plans using one conventional no-margin approach and two margin-generation strategies (modified-fluence and virtual PTV expansion) were generated for 10 early-stage breast cancer patients. A deliberate 1-cm setup shift was applied to simulate positional uncertainty, and all plans were normalized to identical monitor units for dosimetric comparison. Dosimetric assessment was performed using the conformity index (CI), homogeneity index (HI), and a coverage index modified in our group to enhance sensitivity to subtle target undercoverage. Results: Both margin-generation methods substantially improved plan robustness compared with the no-margin approach. The modified coverage index at the 95% prescription level (mCI95%) detected prescription-level undercoverage caused by the simulated setup deviations more sensitively than CI, revealing clear differences between margin and no-margin strategies. The modified-fluence method produced slightly higher mCI95% values than the extended-PTV approach, although the difference was not clinically significant. Conclusions: Both margin-generation techniques are practical and clinically feasible for stabilizing dose delivery in breast IMRT. The mCI effectively identified undercoverage that conventional CI or HI metrics did not detect, proving useful for differentiating plan robustness under geometric uncertainty. A skin-outside margin greater than 1 cm is recommended to mitigate dosimetric degradation in breast IMRT.