• Title/Summary/Keyword: Aerosol Generator

Search Result 30, Processing Time 0.029 seconds

Design and Performance Test of Fungal Aerosol Generator using Vibration Method (진동 방식을 이용한 곰팡이 공기 부유화 장치의 설계 및 성능 평가)

  • Ahn, Ji-Hye;Lee, Sang-Gu;Park, Chul Woo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.143-150
    • /
    • 2012
  • Fungal particles have been known to aggravate indoor air quality. To develop fungal particle cleaning devices requires a well-controlled generator of fungal aerosol particles. In this study, a novel fungal aerosol generator was designed and tested for anti-fungal experiment. Cladosporium cladosporioides was selected as test fungal particle. After aerosolization, the number concentration and the size of particles were measured by aerodynamic particle sizer. The number concentration depended on the vibration strength and vibration period of the designed fungal aerosol generator. For the vibration strength of 10volt and the period of 10 sec (5 sec on and 5 sec off), the stable particle generation with concentration of 10#/cm3 was maintained during 35 minutes.

Separate and integral effect tests of aerosol retention in steam generator during tube rupture accident

  • Lee, Byeonghee;Kim, Sung-Il;Ha, Kwang Soon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2702-2713
    • /
    • 2022
  • A steam generator tube rupture accompanying a core damage may cause the fission product to be released to environment bypassing the containment. In such an accident, the steam generator is the major path of the radioactive aerosol release. AEOLUS facility, the scaled-down model of Korean type steam generator, was built to examine the aerosol removal in the steam generator during the steam generator tube rupture accident. Integral and separate effect tests were performed with the facility for the dry and flooded conditions, and the decontamination factors were presented for different tube configurations and submergences. The dry test results were compared with the existing test results and with the analyses to investigate the aerosol retention physics by the tube bundle, with respect to the particle size and the bundle geometry. In the flooded tests, the effect of submergence were shown and the retention in the jet injection region were presented with respect to the Stokes number. The test results are planned to be used to constitute the aerosol retention model, specifically applicable for the analysis of the steam generator tube rupture accident in Korean nuclear power plants to evaluate realistic fission product behavior.

Development of a Fungal Spore Aerosol Generator: Test with Cladosporium cladosporioides and Penicillium citrinum

  • Lee, Byung-Uk;Kim, Young-Joong;Lee, Chang-Ho;Yun, Sun-Hwa;Bae, Gwi-Nam;Ji, Jun-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.795-798
    • /
    • 2008
  • As the first step to develop efficient means to control fungal spore bioaerosols, we designed, manufactured, and evaluated a fungal spore aerosol generator. We studied the physical and biological properties of the fungal spore bioaerosols on two common fungal species. The results demonstrated that the fungal spore bioaerosol generator effectively produces fungal spore bioaerosols.

Development and performance evaluation of a test particle generator for a field inspection equipment of PM-2.5 sensors (미세먼지 간이측정기 현장 검사용 시험 입자 발생기 개발 및 성능 평가)

  • Chung, Hyeok;Park, Jin-Soo
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.61-68
    • /
    • 2022
  • In this study, a fluidized bed particle generator was developed to generate an aerosol without supply of compressed air and to increase portability. It was assumed that the mixing ratio of the test particles and beads, the input amount, and the air flow rate supplied to the generator would have effect on the aerosol generation characteristics. The product of these three parameters was set as a characteristic parameter and particle generation characteristics according to the change of the characteristic parameter were observed. As a result, it was confirmed that the input amount of test particles and beads was not suitable as a characteristic parameter and a characteristic parameter expressed as a product of the mass mixing ratio and the air flowrate was newly defined. When the new characteristic parameter is applied, it can be confirmed that the total amount of particles generated from the particle generator is a function of the characteristic parameter. As a result of measuring the amount of particle generation by adjusting the characteristic parameter, it was confirmed that the performance required for the test particle generator for the field inspection equipment of PM-2.5 sensors could be satisfied.

Development of mass aerosol particle generator and fabrication of commercial anti-viral air filter (대용량 입자 발생 장치 개발 및 이를 이용한 항바이러스 공조용 공기필터 제조)

  • Park, Dae Hoon;Joe, Yun Haeng;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.151-159
    • /
    • 2016
  • Since airborne viruses have been known to aggravate indoor air quality, studies on development of anti-viral air filter increase recently. In this study, a mass aerosol particle generator for coating a commercial air filter (over $300{\times}300mm^2$) was built, and evaluated by comparing a commercial particle generator. Then, via this device, a commercial air filter was coated with anti-viral material ($SiO_2-Ag$ nanoparticles in this study), so fabrication of commercial anti-viral air filter was performed and the pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. The result showed that the particle generation of the new generator was more than about 8.5 times over which of the commercial one. Consequently, $SiO_2-Ag$ particle coating on a filter does not have significant effects on the filtration efficiency and pressure drop with different areas, and the average anti-viral efficiency of the $SiO_2-Ag$ filter was about 92% when the coating areal density was $1.0{\times}10^{12}particles/m^2$.

Key Findings from the Artist Project on Aerosol Retention in a Dry Steam Generator

  • Dehbi, Abdelouahab;Suckow, Detlef;Lind, Terttaliisa;Guentay, Salih;Danner, Steffen;Mukin, Roman
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.870-880
    • /
    • 2016
  • A steam generator tube rupture (SGTR) event with a stuck-open safety relief valve constitutes one of the most serious accident sequences in pressurized water reactors (PWRs) because it may create an open path for radioactive aerosol release into the environment. The release may be mitigated by the deposition of fission product particles on a steam generator's (SG's) dry tubes and structures or by scrubbing in the secondary coolant. However, the absence of empirical data, the complexity of the geometry, and the controlling processes have, until recently, made any quantification of retention difficult to justify. As a result, past risk assessment studies typically took little or no credit for aerosol retention in SGTR sequences. To provide these missing data, the Paul Scherrer Institute (PSI) initiated the Aerosol Trapping In Steam GeneraTor (ARTIST) Project, which aimed to thoroughly investigate various aspects of aerosol removal in the secondary side of a breached steam generator. Between 2003 and 2011, the PSI has led the ARTIST Project, which involved intense collaboration between nearly 20 international partners. This summary paper presents key findings of experimental and analytical work conducted at the PSI within the ARTIST program.

Design of Aerosol Generator for Inhalation Toxicology Study of Lead and Evaluation with Real Time Monitoring (납의 흡입독성 연구를 위한 에어로졸 발생장치의 고안 및 실시간 모니터링을 이용한 성능평가)

  • Jeung Jae Yeal;Kim Jung Man;Kim Tae Hyeung;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.2
    • /
    • pp.373-379
    • /
    • 2002
  • This paper was the design of aerosol generator for inhalation toxicology study of lead and evaluation with real time monitoring, and applied several engineering methodology to classical aerosol generator to cope with it's disadvantages. According to the testing conditions, source temperature 50℃ and inlet-duct band heater temperature 150℃, aerosol generation results for sodium chloride and lead acetate were as followings: CPM(Count Per Minute) for Sodium chloride that used for the testing material in aerosol generation and inhalation system was decreased in the 2nd and the 3rd hour's serial trials, but CVs(coefficient of variation) were maintained within 10%. CPMs for 5 and 2.5 gram of lead acetate that used for aerosol generation and inhalation exposure of lead showed similar results because of the sedimentation of lead acetate on piezoelectric crystal with time. For that reason, heating and mixing of nebulizing solution will be needed to generate lead aerosol with stable profile and maximum generation efficiency. Fluctuations of 10 and 5 gram lead acetate were low but 2.5gram was high. However, CVs for 10, 5, and 2.5gram lead acetate were within 10%. Considering the theoretical efficiencies for sodium chloride and lead acetate, 5gram sodium chloride and 2.5gram lead acetate were appropriate choice. Aerosol generation characteristics for two materials with 1 hour interval were different with respect to the fluctuation of CPM and the decrease to 10gram in it's material. For that reason, sodium chloride can not be used to estimate the aerosol generation and it's related parts for lead acetate. According to the testing conditions, source temperature 20, 50, 70℃, and inlet-duct band heater temperature 20, 50, 100, 150, 200℃, aerosol generation results for sodium chloride and lead acetate were as followings: Excluding inlet-duct band temperature 200℃, maximum CPM for sodium chloride was manifested in source temperature 70℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing. Maximum CPMs for 10, 5, and 2.5gram sodium chloride were from source temperature 70℃ and inlet-duct band temperature 20℃. Excluding inlet-duct band temperature 50, 200℃, maximum CPMs for lead acetate were indicated in source temperature 50℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing for lead inhalation study. Source and inlet-duct band temperatures for 10, 5, 2.5gram lead acetate were 50 and 100℃, 50 and 100℃, 50 and 150℃, respectively. In conclusion, considering above 2 paragraphs of results for aerosol generation, 5gram efficiencies for sodium chloride, lead acetate were higher than 2.5gram's. If inlet-duct band temperature was same, aerosol generation was increased with increase of source temperature. To get maximum aerosol generation will be the conditions that set the appropriate inlet-duel band temperature for each materials and increase the source temperature.

Response of laser light active scattering aerosol spectrometer to light-absorbing aerosol particulates (광흡수성 분체입자에 대한 레이저산란광 분체입도측정기의 반응 특성)

  • Jeung, I. S.
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.55-63
    • /
    • 1984
  • Berglund-Liu 진동방식 단분산 분체입자 발생기(Berglund-Liu vibrating orifice monodisperse aerosol generator)에 의하여 제작한 단분산 광흡수성 표준분체입자를 사용하여 레이저 산란광 분체입도 측정기 (Knollenberg active scattering aerosol spectrometer)의 반응특성을 조사하 였다. 실험결과, 기기의 반응특성은 Mie 산란이론에 의하여 계산한 이론치와 매우 잘 일치하며 특히 광흡수성 분체입자는 광통과성 분체입자가 다의적인 특성을 나타내는 것에 반하여 거의 단조증가하는 일의적인 특성을 가지고 있으며 광흡수성 분체입자의 반응특성이 제작자의 교정 치에 가까운 결과를 나타내었다.

  • PDF

Synthesis and Characterization of TiO2, Cu2O and Al2O3 Aerosol Nanoparticles Produced by the Multi-Spark Discharge Generator

  • Efimov, Alexey;Lizunova, Anna;Sukharev, Valentin;Ivanov, Victor
    • Korean Journal of Materials Research
    • /
    • v.26 no.3
    • /
    • pp.123-129
    • /
    • 2016
  • The morphology, crystal structure and size of aerosol nanoparticles generated by erosion of electrodes made of different materials (titanium, copper and aluminum) in a multi-spark discharge generator were investigated. The aerosol nanoparticle synthesis was carried out in air atmosphere at a capacitor stored energy of 6 J, a repetition rate of discharge of 0.5 Hz and a gas flow velocity of 5.4 m/s. The aerosol nanoparticles were generated in the form of oxides and had various morphologies: agglomerates of primary particles of $TiO_2$ and $Al_2O_3$ or aggregates of primary particles of $Cu_2O$. The average size of the primary nanoparticles ranged between 6.3 and 7.4 nm for the three substances studied. The average size of the agglomerates and aggregates varied in a wide interval from 24.6 nm for $Cu_2O$ to 46.1 nm for $Al_2O_3$.