• 제목/요약/키워드: Artificial Saliva

검색결과 155건 처리시간 0.023초

인공타액 오염이 수종 상아질접착제와 상아질간의 결합에 미치는 영향 (INFLUENCE OF ARTIFICIAL SALIVA CONTAMINATION ON BONDING OF DENTIN ADHESIVES TO DENTIN)

  • 류미애;양규호;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.383-397
    • /
    • 1992
  • The purpose of this study was to evaluate the influence of artificial saliva contamination on bonding of several dentin adhesives to dentin. Sixty - three human molar teeth extracted within a month were used. Each tooth was sectioned longitudinally in a buccolingual direction to obtain 126 specimens. These specimens were randomly divided into three groups and were treated by Scotchbond 2, Gluma and All bond. Each group was subdivided into three subgroups; normal group not contaminated with artificial saliva, contaminated with artificial saliva and dried group, and contaminated with artificial saliva and washed and dried group. Enamel/dentin bonding agent(Dental Adhesive of Scotchbond 2) was applied and light cured on the treated dentin surfaces. Thereafter P - 50 were cured on them, and specimens were stored in $37^{\circ}C$ artificial saliva for 24 hours before measuring shear bond strength. Shear bond strengths were determined using an universal testing machine with cross head speed 1mm/min and SEM examinations were conducted to evaluate the resin - dentin interface and degree of penetrating resin string into the dentinal tubules. The following results were obtained. 1. Normal groups not contaminated with artificial saliva showed greater shear bond strength than any other group contaminated with artificial saliva(P<0.01). 2. The shear bond strengths showed no significant difference between washed groups with distilled water and not washed groups after contamination with artificial saliva(P>0.05). 3. In normal groups, the shear bond strength of A group was significantly greater than in any other group(P<0.01). 4. In Sand G groups, fractures after shear bond strength tests occured adhesively on resintooth interface in all specimens. But in A groups, fracture of the normal group occured cohesively in dentin and fracture of the contaminated groups occured adhesively and cohesively. 5. On SEM examination, the number of resin strings penetrated into dentinal tubules were the greatest in normal groups, followed by, in descending order, washed groups and not washed groups after contamination with artificial saliva.

  • PDF

Use of Resin Infiltrant to Prevent Discoloration after Teeth Whitening

  • Min, Ji-Hyun
    • 치위생과학회지
    • /
    • 제22권3호
    • /
    • pp.156-163
    • /
    • 2022
  • Background: This study attempted to apply resin infiltrant (RI) as a method to maintain the effect of tooth bleaching treatment and compared it with fluoride varnish (FV) or artificial saliva to evaluate the effect. Methods: Sixty healthy lozenge specimens were classified into five groups. Group 1 was the negative control group, and discoloration was induced after artificial saliva treatment of the tooth specimen (G1S+C). Group 2 was a positive control group, in which pigmentation was induced after bleaching treatment and artificial saliva treatment (G2 B+S+C). Coloration was induced in group 3 (experimental group 1) after bleaching treatment and artificial saliva treatment, followed by application of fluorine varnish (G3B+FV+S+C). Coloration was induced in Group 4 (experimental group 2) after applying RI after bleaching treatment and artificial saliva treatment (G4B+RI+S+C). Pigmentation was induced in group 5 (experimental group 3) after bleaching treatment and artificial saliva treatment, followed by acid treatment (etching) and treatment with RI (G5B+E+RI+S+C). Coffee and wine were used to induce discoloration. The lightness value (L*) of the CIE L*a*b* color system was obtained by image analysis. Kruskal-Wallis H analysis was performed for the mean difference in L* values by group. Results: When coloration was induced with coffee, there was no significant difference in L* value between artificial saliva (G2 B+S+C), FV (G3B+FV+S+C), and RI (G4B+RI+S+C, G5B+E+RI+S+C) groups. There was no significant difference in L* values between the artificial saliva (G2 B+S+C), FV (G3B+FV+S+C), and RI (G4B+RI+S+C, G5B+E+RI+S+C) groups, even in the case of wine induced coloration. Conclusion: It was confirmed that artificial saliva or RI treatment had similar effects to the FV previously used to maintain the effect of tooth bleaching treatment.

불소와 칼슘의 법랑질 재광화 효과에 대한 생체외 연구 (EFFECT OF FLUORIDE AND CALCIUM ON ENAMEL REMINERALIZATION IN VITRO)

  • 이광희
    • 대한소아치과학회지
    • /
    • 제31권4호
    • /
    • pp.624-629
    • /
    • 2004
  • 침식된 치아 법랑질의 효과적인 재광화 방법에 관한 연구의 일환으로, $0.1{\sim}1.0%$ 구연산 용액에서 60분간 탈회시킨 사람 소구치 법랑질을 인공타액, 100ppm 및 1000ppm 불소가 첨가된 인공타액, 1000ppm 칼슘이 첨가된 인공타액, 100ppm 불소와 1000ppm 칼슘이 첨가된 인공타액에 각각 넣고 재광화시키면서, 3시간과 6시간 경과시에 표면미세경도를 측정하였다. 불소나 칼슘을 첨가하지 않은 인공타액 및 불소 100ppm을 첨가한 인공타액에서는 6시간 동안 유의한 재광화가 일어나지 않았으며, 불소 1000ppm을 첨가한 인공타액에서는 3시간 후에 유의한 재광화가 관찰되었고 3시간부터 6시간 사이에는 유의한 재광화가 일어나지 않았으며, 칼슘 1000ppm을 첨가한 인공타액 및 불소 100ppm과 칼슘 1000ppm을 첨가한 인공타액에서는 3시간 후와 6시간 후에 유의한 재광화가 관찰되었다(유의수준 P=0.05). 불소나 칼슘을 첨가하지 않은 인공타액 또는 불소 100ppm을 첨가한 인공타액에 비해 불소 100ppm과 칼슘 1000ppm을 첨가한 인공타액의 재광화효과가 유의하게 더 컸으며, 불소를 100ppm 또는 1000ppm으로 첨가한 것, 불소 농도를 100ppm에서 1000ppm으로 증가시킨 것, 칼슘을 1000ppm으로 첨가한 것은 재광화효과를 유의하게 증가시키지 않았다.

  • PDF

수종의 Magnet를 이용한 Overdenture의 유지력에 관한 비교연구 (A COMPARATIVE OF RETENTIVE FORCE OF VARIOUS OVERDENTURES USING SEVERAL MAGNETS)

  • 허경숙;허성주;조인호
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.49-57
    • /
    • 1991
  • The magnets were widely used to increase the retention of overdentures. The purpose of this study was to compare the break load between overdentures and edentulous models. For this study, Model former(U-402) was used for model fabrication and four different magnets were used for evaluation of break load. The artificial saliva was used between overdenture and model. Breakaway loads were tested with an Instron 1122 at a speed of 2mm/min. The results were as follows. 1. The retentivee forces complete dentures with artificial saliva were than the retentive forces of complete detures without artificial saliva. 2. Magnetic overdenture with artificial saliva showed best retentive force, magnetic overdenture without artificial saliva showed the next retentive force, and the complete denture without artificial saliva showed the worst retention. 3. As the magnetic sizes increased, the retentive forces of magnetics were increased. 4. The retentive force of nipple shape magnet is greater than the retentive force of flate shape magnet in the same size.

  • PDF

The effect of two artificial salivas on the adhesion of Candida albicans to heat-polymerized acrylic resin

  • Oncul, Burcin;Karakis, Duygu;Al, Funda Dogruman
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.93-97
    • /
    • 2015
  • PURPOSE. Xerostomia can diminish the quality of life, leads to changes in normal chemical composition of saliva and oral microbiata, and increases the risk for opportunistic infections, such as Candida albicans. Various artificial salivas have been considered for patients with xerostomia. However, the knowledge on the antifungal and antiadhesive activity of artificial saliva substitutes is limited. The aim of the present study was to evaluate influence of two artificial salivas on the adhesion of Candida albicans to the polymethylmethacrylate disc specimens. MATERIALS AND METHODS. Two commercial artificial salivas (Saliva Orthana and Biotene Oral Balance Gel) were selected. 45 polymethylmethacrylate disc specimens were prepared and randomly allocated into 3 groups; Saliva Orthana, Biotene-Oral Balance gel and distilled water. Specimens were stored in the artificial saliva or in the sterile distilled water for 60 minutes at $37^{\circ}C$. Then they were exposed to yeast suspensions including Candida albicans. Yeast cells were counted using ${\times}40$ magnification under a light microscope and data were analysed. RESULTS. Analysis of data indicated statistically significant difference in adhesion of Candida albicans among all experimental groups (P=.000). Findings indicated that Saliva Orthana had higher adhesion scores than the Biotene Oral Balance gel and distilled water (P<.05). CONCLUSION. In comparison of Saliva Orthana, the use of Biotene Oral Balance Gel including lysozyme, lactoferrin and peroxidase may be an appropriate treatment method to prevent of adhesion of Candida albicans and related infections in patients with xerostomia.

치실 종류에 따른 치면세마 시행에 대한 불소도포 효과 (Effect of fluoride application after dental prophylaxis by the type of dental floss)

  • 김경희;하명옥;홍남희;조민정
    • 한국치위생학회지
    • /
    • 제16권1호
    • /
    • pp.77-83
    • /
    • 2016
  • Objectives: This study was carried out to investigate the effect of fluoride application after dental prophylaxis by the type of dental floss. Methods: Artificial caries lesion was made on the surface of cow's permanent teeth having sound enamel surface and vickers hardness number(VHN) was measured. Specimens were classified into APF gel group and artificial saliva group. Each group was divided into waxed floss group and unwaxed flossed group. All specimens were immersed into the artificial saliva for one minute and dental flossing was applied to waxed or unwaxed floss. After washing and drying, APF gel groups were applied with fluoride for four minutes and artificial saliva groups were immersed into the artificial saliva for four minutes. After treatment, specimens were measured by VHN and surface conditions of enamel were confirmed by scanning electron microscopy(SEM). Results: VHN of waxed flossing and fluoride application group increased to $6.78{\pm}2.75$. VHN of unwaxed flossing and fluoride application group increased to $7.36{\pm}2.51$. There was no significant difference between waxed and unwaxed groups(p>0.05). VHN of waxed flossing and artificial saliva group increased to $1.07{\pm}2.84$. VHN of waxed flossing and artificial saliva group increased to $1.05{\pm}3.13$. There was no significant difference between waxed and unwaxed groups(p>0.05). There was significant increase in VHN between waxed/unwaxed flossing and fluoride application. However, waxed/unwaxed flossing with artificial saliva showed no significant VHN increase. SEM demonstrated no residue on the enamel surface in the waxed flossing groups. Conclusions: No difference was found in the remineralization of enamel by waxed flossing or unwaxed flossing.

생체유사환경 하의 치과용 임플란트의 피로강도 평가 및 수명 향상법 (Fatigue Strength of Dental Implant in Simulated Body Environments and Suggestion for Enhancing Fatigue Life)

  • 김민건
    • 대한기계학회논문집A
    • /
    • 제38권3호
    • /
    • pp.259-267
    • /
    • 2014
  • 치과용 임플란트를 대상으로 하여 건전환경 및 생체 내의 인자들을 유사하게 반영한 생체유사환경 하에서 피로시험을 수행하였다. 생체유사환경으로는 링거액 환경과 인공타액환경을 각각 사용하였다. 우선 건전환경과 생체유사환경 하에서의 피로수명 및 피로한도를 평가하였다. 또한 피로수명을 향상시킬 수 있는 한 가지 방법을 제안하였다. 인공타액 하에서의 피로수명이 링거환경보다 대체적으로 감소하였다. 시편에 대한 부식작용은 인공타액이 링거액보다 훨씬 크다. 이러한 부식의 차이가 두 경우의 피로수명의 차이로 나타난 것으로 판단된다. 질화처리된 지대주 나사의 질화경화층을 제거하고, 질소확산층을 최표면으로 하는 지대주 나사를 사용한 임플란트의 피로수명은 텅스텐카바이드를 코딩한 기존 제품에 비해 최대 8배의 피로수명 향상효과가 확인되었다.

Potentiostat를 이용한 타액에서의 아말감부식에 대한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY BY USING A POTENTIOSTAT ON THE CORROSION OF AMALGAMS IN SALIVA)

  • 손윤희;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.534-548
    • /
    • 1994
  • The purpose of this study is to observe the corrosion characteristics of seven dental amalgams (CAULK FINE CUT, CAULK SPHERICAL, OPTALLOY II, DISPERSALLOY, HI VERALOY, TYTIN, VALIANT) through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydrolic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam in 0.9% saline solution, Fusayama's artificial saliva, and stimulated parotid saliva at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was. -1700m V ~ + 400m V(vs. S. C. E) in the working electrode and the scan rate was 50m V /sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the stimulated parotid saliva shifted to more anodic direction than those in saline solution, and the current density in the stimulated parotid saliva was lower than that in saline solution. Those in Fusayama's artificial saliva was similar to those in stimulated parotid saliva. 2. The anodic polarization profiles in Fusayama's artificial saliva and stimulated parotid saliva indicated a region of slow slope current density, which is extending from the corrosion potential to the potential of anodic current peak, but that in 0.9% saline solution indicated no region of slow slope. 3. The corrosion potentials for CAULK FINE CUT, CAULK SPHERICAL, and OPT ALLOY II had the similarity in 0.9% saline solution, Fusayama's artificial saliva and stimulated parotid saliva, but those for high coper amalgam and VALIANT had no similarity. 4. The current density for TYTIN amalgam in stimulated parotid saliva was the lowest among the others. 5. As for current density, there was no significant difference between palladium enriched VALINAT and other high copper amalgams.

  • PDF

레진의치상 수리 시 인공타액 흡수도에 따른 결합강도 연구 (A Study of Bonding Strength of Repaired Resin Denture Base by Artificial Saliva Absorption)

  • 강명호;이명곤
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.25-35
    • /
    • 2011
  • Purpose: There are some advantages of the acrylic resin denture base ; appropriate strength, volume safety, simple processing apparatus, and low cost. But, it have a weakness for fracture by intense pressure or shock. However, the repairs for resin denture base are possible using various materials and techniques. There is a few studies in repairs for resin denture base, but not clinical researches. And there is no studies in absorbed saliva into the region of fracture and bond strength. This study is to observe re-bond strength of resin denture base after repairing under saliva absorption. Methods: The samples were made of heat curing resin and the rectangular parallelepiped specimens which were 50mm long, 10mm wide and 3mm high. The four different groups immersed in the artificial saliva for 2 weeks were prepared, 1) no repaired control samples, 2) immediately repaired samples, 3) repaired samples after 1 day dry, and 4) repaired samples after 3 days dry. The prepared samples were repaired by two different curing materials, self curing resin and heat curing resin method. Each groups composed of 10 specimens were experimented with the three point bending tests for bonding strength measuring Results: There were under condition absorbed in the artificial saliva and repaired by self curing resin method, repaired specimens after 1 day and 3 days dry groups had higher values of bonding strengths than control group, and bonding strengths of immediately repaired samples were similar to those of control samples (p<0.05). There were under condition immersed in the artificial saliva and repaired by heat curing resin method, immediately repaired samples showed similar values to bonding strengths of control groups, and repaired samples after 1 day and 3 days dry groups were lower than those of control group (p>0.05). Conclusion: In this study, the repairs for resin denture base were remarkably high values of bonding strengths than those of the past, and showed that have stable bonding strengths independent of saliva absorption of denture base, so present repairs for resin denture base can be performed, regardless of saliva conditions.

인공타액하에서 수종 교정선의 마찰력에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON FRICTIONAL FORCES OF VARIOUS ORTHODONTIC WIRES UNDER ARTIFICIAL SALIVA)

  • 황현식;박영철
    • 대한치과교정학회지
    • /
    • 제19권1호
    • /
    • pp.245-256
    • /
    • 1989
  • Translational movement along an arch wire requires sufficient force to overcome frictional forces between bracket and arch wire. The orthodontist must appreciate the importance of friction in this process, and study out the influencing factors on the level of friction. The purpose of this study was to evaluate the effect of artificial saliva on frictional resistances generated between the bracket and arch wire. Independent variables of this study were arch wire material, angulation and environment. Static frictional forces of cobalt-chromium, heat-treated cobalt-chromium, beta-titanium, stainless steel wires were measured under non-angulated dry, angulated dry, non-angulated saliva, angulated saliva conditions. The results were as follows: 1. Stainless steel wires showed lower friction values in non-angulated dry condition, and heat-treated cobalt-chromium wires showed higher friction values in angulated dry condition. Higher friction values were showed in order of cobalt-chromium. stainless steel, heat-treated cobalt-chromium and beta-titanium wires in non-angulated saliva condition. and were showed in order of stainless steel, cobalt-chromium, heat-treated cobalt-chromium, beta-titanium wires in angulated saliva condition. 2. Angulation increased friction for stainless steel wires under dry condition. 3. Artificial saliva decreased friction for cobalt-chromium wires and increased friction for stainless steel wires under non-angulated condition. 4. Artificial saliva decreased friction for all wires except beta-titanium wires under angulated condition. 5. Regardless of angulation or environment. heat-treated cobalt-chromium and beta-titanium wires showed higher friction values, and stainless steel wires showed lower friction values.

  • PDF