• Title/Summary/Keyword: CRA

Search Result 127, Processing Time 0.029 seconds

Immunoadjuvant Activity of Chlorogenic Acid (Chlorogenic Acid의 면역보조제 효과)

  • Han, Yong-Moon
    • YAKHAK HOEJI
    • /
    • v.54 no.6
    • /
    • pp.494-499
    • /
    • 2010
  • We have been focussing on discovery of natural compounds that have immunoregulatory activities for many years. In the present study, we investigated if chlorogenic acid (CRA), a polyphenolic compound, has an immunoadjuvant activity. Prior to examining the immunoadjuvant activity, effect of CRA on proliferation of T- or B-lymphocyte was determined. Results showed that CRA enhanced the proliferation of those lymphocytes in dose-dependant manner (P<0.05), and the proliferation enhancement by CRA was appeared to be more effective to B-cells than to T-cells. Based on these observations, it was tested with bovine serum albumin (BSA) and Candida albicans cell wall (CACW) as antigenic sources if CRA has an immunoadjuvant activity. In experiments, BSA alone or a mixture of BSA plus CRA was injected intraperitoneally to mice (BALB/c strain). For a negative control, mice were given only diluent (DPBS) by the same route. In other experiment, CACW was tested by the same way as did with BSA. Three weeks after the first immunization these animals were boosted. Antisera collected from the mice one week after the booster were analyzed by ELISA. Results displayed that the induction of anti-BSA antibody was increased in mice that received the mixture of BSA and CRA as compared to anti-BSA induction in BSA only-given mice groups (P<0.05). In case of CACW, a similar observation as did with BSA was made, resulting in that there was app. 40% increased production of the anti-CACW antiserum from the combination (CACW plus CRA)-received mice as compared to antiserum induction from CACW alone-given animals. Taken all together, these data indicate that CRA has an ability of enhancing antibody production regardless of nature of antigenic sources. Presumably, activation of B-cell proliferation by CRA may plays an important role in the immunoadjuvant activity of the polyphenolic compound.

The Exception Case about the Diagnose Forward Head Posture using the CranioVertebra Angle, CranioRotation Angle and Cobb angle : a Case Report

  • Park, Han-Kyu;Lee, Sang-Yeol;Kim, Tae-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.29-34
    • /
    • 2015
  • PURPOSE: The purpose of present study was to introduces an exceptional case in measurement methods (CVA, CRA and Cobb angle) to identify the FHP with verified reliability and validity. Subjects: Three males aged 30 years were recruited: A Normal, B and C who have FHP. METHODS: All the subjects were measured CVA, CRA and Cobb angle with the Photogrammetry and Radiography. RESULTS: The results revealed that it is not enough for measurement methods to identify the FHP using CVA, CRA and Cobb angle. On Photogrammetry values; CVA had $65^{\circ}$, CRA was $148^{\circ}$ of Normal subject A and CVA had $61^{\circ}$, CRA was $149^{\circ}$ of FHP subject B and CVA had $51^{\circ}$, CRA was $149^{\circ}$ of FHP subject C. On Radiography values; CVA had $73^{\circ}$, CRA was $148^{\circ}$ and Cobb was $50^{\circ}$ of Normal subject A and CVA had $70^{\circ}$, CRA was $150^{\circ}$ and Cobb was $53^{\circ}$ of FHP subject B and CVA had $61^{\circ}$, CRA was $153^{\circ}$ and Cobb was $31^{\circ}$ of FHP subject C. CONCLUSION: The reliable CVA, CRA and Cobb angle use methods from the previous studies might not be suitable for the diagnose the FHP. We think that it is necessary to have more detailed evaluation methods and the radiography is also needed for clear evaluations because of some possible exceptions.

Psychometric Properties of the Korean Version of the Caregiver Reaction Assessment(K-CRA) (한국형 부양자반응척도(Caregiver Reaction Assessment)의 구성타당화 연구)

  • Lee, Minhong
    • 한국노년학
    • /
    • v.29 no.2
    • /
    • pp.407-424
    • /
    • 2009
  • This study aims to evaluate psychometric properties of the korean version of the caregiver reaction assessment. A total of 253 family caregivers for older adults with physical or mental impairments are recruited using the purposive sampling method. The psychometric properties of the instrument are tested by item-analysis, exploratory factor analysis(EFA), and convergent and criterion-related validity. The results show that the internal consistency values for the five dimensions of the K-CRA are good. The convergent and criterion-related validity is empirically confirmed. The EFA with the principal component method reveals the factor structure in the observed variables. The findings of the study confirmed that the K-CRA was both reliable and valid. In conclusion, the K-CRA would be useful in clinical and research settings in South Korea.

Anti-inflammatory Effect of 9-cis Retinoic Acid on the Human Mast Cell Line, HMC-1

  • Lee, Ji-Sook;Kim, In-Sik
    • Biomedical Science Letters
    • /
    • v.13 no.2
    • /
    • pp.149-152
    • /
    • 2007
  • Mast cells play important roles in immune-related diseases, in particular, allergic diseases. Although 9-cis retinoic acid (9CRA) has been known as an immune regulator, its function in mast cells is not characterized well. In a previous paper, we demonstrated that 9CRA differentially decreases both CCR2 expression and the MCP-1-induced chemotactic activity of the human mast cell line, HMC-1 cells. In the present study, we examined the effects of 9CRA on the migration and expressions of inflammatory cytokines in HMC-1 cells. It was found that 9CRA significantly inhibited the migration of HMC-1 cells in response to stem cell factor (P<0.01), and it had no effect on the mRNA and protein expression of c-kit, a receptor binding to SCF. We further investigated the alternation of inflammatory cytokine expression and identified that 9CRA blocked the mRNA and protein expressions of Th2 cytokines such as interleukin (IL)-4 and IL-5. Taken together, our results demonstrate that 9CRA blocks SCF-induced cell movement and the protein secretion of IL-4 and IL-5, and this indicates that 9CRA may have anti-inflammatory effects on mast cells.

  • PDF

Trend and Review of Corrosion Resistant Alloy (CRA) for Offshore Pipeline Engineering (내식합금 (CRA) 동향 및 해양 파이프라인 설계 적용에 대한 고찰)

  • Yu, Su-Young;Choi, Han-Suk;Lee, Seung-Keon;Kim, Do-Kyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.85-92
    • /
    • 2014
  • Offshore fields are increasingly important for the development of offshore resources due to the growing energy needs. However, an offshore field for oil and gas production has difficult development conditions, e.g., high temperature, high pressure, sweet/sour compositions of fluids, etc. Corrosion is one of the biggest issues for offshore pipeline engineering. In this study, a Corrosion Resistant Alloy (CRA) pipe for corrosion prevention was investigated through its global demand and trends, and three types of CRA pipelines were introduced with detailed explanations. The usefulness of CRA was also evaluated in comparison to a carbon steel pipeline in terms of the structural strength, cost, and other factors. Offshore pipeline engineering, including mechanical design and verification of the results through an installation analysis based on numerical software, was performed for the carbon steel type and solid CRA type. The results obtained from this study will be useful data for CRA pipeline designers and researchers.

CRA Based Robust Controller Design for PWM Converter (CRA 기법을 이용한 PWM 컨버터의 강인제어기 설계)

  • Kim, Soo-Cheol;Kim, Hyung-Chul;Chung, Gyo-Bum;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.183-190
    • /
    • 2007
  • In this paper, a robust controller for PWM converter is proposed. The proposde converter controller consists of a PI controller for DC output voltage and a current controller using error-space approach for maintaining the sinusoidal current waveform and unity power factor. Conventionally, the try and error method has been used to design the current controller considering the switching frequency of the devices and sampling frequency of the digital controller. But this proposed method is based on characteristic ratio assignment(CRA) method which has the advantage to design the optimal gain to meet the referenced response and overshoot within the limit range. First, the CRA based current controller algorithm is explained. Then the validity of proposed controller is verified through the PSiM simulation and experience results.

Controller Design for the Converter using CRA Method (CRA 기법을 이용한 컨버터 제어기 설계)

  • Kim, Hyung-Chul;Kim, Soo-Cheol;Lee, Jae-Moon;Yeom, Sang-Gu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.980-981
    • /
    • 2006
  • 전력변환 장치에서 기존의 PID 제어기의 해석적인 해를 얻는 것은 매우 어려운 일이다. 최근에 단상 UPS용 인버터 시스템에서 CRA 기법을 이용한 새로운 제어알고리즘을 바탕으로 시스템의 제어기의 제어상수를 해석적으로 접근하여 좋은 성능을 얻은 바 있다. CRA 기법은 해석적으로 시스템의 응답속도 및 오버슈트를 임의의 제한범위 내로 설계할 수 있도록 하는 장점이 있다. 이러한 CRA 기법을 사용하여 컨버터 제어기 설계부분에 적응하여 해석적인 해를 얻고 PSiM 시뮬레이션을 통해 오버슈트와 빠른 응답을 확인한다.

  • PDF

Conflict Resolution Acts of Rural Spouses (도시근교 농촌부부의 갈등표출행동에 관한 연구)

  • 이정화;최은숙;한경혜
    • Korean Journal of Rural Living Science
    • /
    • v.6 no.1
    • /
    • pp.41-54
    • /
    • 1995
  • This study is to investigate the marital conflict resolution acts (CRA) of rural spouses and to explore the relationship between the CRA and several important factors : socio-demographic, marital relation and drinking pattern factors. Participants in this study are 150 rural women who are married and live with their husband. A modification of the Conflict Tactics Scale is used to measure the CRA of four levels, reasoning, verbal aggression, minor physical violence, and heavy physical violence. The major findings of this study are as follows. First the frequencies of each type of the CRA-reasoning, verbal aggression, minor physical violence and heavy physical violence-are 12.1%, 57.9%, 17.1% and 12.9% respectively. Therefore, the verbal aggression is the most prevalent type of the CRA Second, the result from multiple regression shows that the conflict from husband's whoring, husband's drinking capacity and family type have a meaningful impact on husband's physical violence.

  • PDF

Numerical simulation of complex hexagonal structures to predict drop behavior under submerged and fluid flow conditions

  • Yoon, K.H.;Lee, H.S.;Oh, S.H.;Choi, C.R.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.31-44
    • /
    • 2019
  • This study simulated a control rod assembly (CRA), which is a part of reactor shutdown systems, in immersed and fluid flow conditions. The CRA was inserted into the reactor core within a predetermined time limit under normal and abnormal operating conditions, and the CRA (which consists of complex geometric shapes) drop behavior is numerically modeled for simulation. A full-scale prototype CRA drop test is established under room temperature and water-fluid conditions for verification and validation. This paper describes the details of the numerical modeling and analysis results of the several conditions. Results from the developed numerical simulation code are compared with the test results to verify the numerical model and developed computer code. The developed code is in very good agreement with the test results and this numerical analysis model and method may replace the experimental and CFD method to predict the drop behavior of CRA.

Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR 제어봉집합체 낙하성능시험)

  • Lee, Young Kyu;Kim, Hoe Woong;Lee, Jae Han;Koo, Gyeong Hoi;Kim, Jong Bum;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.