• 제목/요약/키워드: Cathodic phase-1st stimulus

검색결과 3건 처리시간 0.016초

Effect of Stimulus Waveform of Biphasic Current Pulse on Retinal Ganglion Cell Responses in Retinal Degeneration (rd1) mice

  • Ahn, Kun No;Ahn, Jeong Yeol;Kim, Jae-Hyung;Cho, Kyoungrok;Koo, Kyo-In;Senok, Solomon S.;Goo, Yong Sook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제19권2호
    • /
    • pp.167-175
    • /
    • 2015
  • A retinal prosthesis is being developed for the restoration of vision in patients with retinitis pigmentosa (RP) and age-related macular degeneration (AMD). Determining optimal electrical stimulation parameters for the prosthesis is one of the most important elements for the development of a viable retinal prosthesis. Here, we investigated the effects of different charge-balanced biphasic pulses with regard to their effectiveness in evoking retinal ganglion cell (RGC) responses. Retinal degeneration (rd1) mice were used (n=17). From the ex-vivo retinal preparation, retinal patches were placed ganglion cell layer down onto an $8{\times}8$ multielectrode array (MEA) and RGC responses were recorded while applying electrical stimuli. For asymmetric pulses, 1st phase of the pulse is the same with symmetric pulse but the amplitude of 2nd phase of the pulse is less than $10{\mu}A$ and charge balanced condition is satisfied by lengthening the duration of the pulse. For intensities (or duration) modulation, duration (or amplitude) of the pulse was fixed to $500{\mu}s$($30{\mu}A$), changing the intensities (or duration) from 2 to $60{\mu}A$(60 to $1000{\mu}s$). RGCs were classified as response-positive when PSTH showed multiple (3~4) peaks within 400 ms post stimulus and the number of spikes was at least 30% more than that for the immediate pre-stimulus 400 ms period. RGC responses were well modulated both with anodic and cathodic phase-1st biphasic pulses. Cathodic phase-1st pulses produced significantly better modulation of RGC activity than anodic phase-1st pulses regardless of symmetry of the pulse.

Spatial and Temporal Electrodynamics in Acuzones: Test-Induced Kinematics and Synchronous Structuring. Phenomenological Study

  • Babich, Yuri F.;Babich, Andrey Y.
    • Journal of Acupuncture Research
    • /
    • 제38권4호
    • /
    • pp.300-311
    • /
    • 2021
  • Background: So far there is no confidence in the basics of acupoint/meridian phenomena, specifically in spatial and temporal electrical manifestations in the skin. Methods: Using the skin electrodynamic introscopy, the skin areas of 32 × 64 mm2 were monitored for spectral electrical impedance landscape with spatial resolution of 1 mm, at 2 kHz and 1 MHz frequencies. The detailed baseline and 2D test-induced 2 kHz-impedance phase dynamics and the 4-parameter time plots of dozens of individual points in the St32-34 regions were examined in a healthy participant and a patient with mild gastritis. Non-thermal stimuli were used: (1) (for the sick subject), microwaves and ultraviolet radiation applied alternately from opposite directions of the meridian; and (2) (for the healthy one) microwaves to St17, and cathodic/anodic stimulation of the outermost St45, alternately. Results: In both cases, the following phenomena have been observed: emergence of in-phase and/or antiphase coherent structures, exceeding the acupoint conditional size of 1 cm; collective movement along the meridian; reversible with a reversed stimulus; counter-directional dynamics of both whole structures and adjacent points; local abnormalities in sensitivity and dynamics of the 1 MHz and 2 kHz parameters indicating existence of different waveguide paths. Conclusion: It is assumed that these findings necessitate reconsideration of some basic methodological issues regarding neurogenic/acupuncture points as spatial and temporal phenomena; this requires development of an appropriate approach for identifying the acuzones patterns. These findings may be used for developing new approaches to personalized/controlled therapy/treatment.

The advantage of topographic prominence-adopted filter for the detection of short-latency spikes of retinal ganglion cells

  • Ahn, Jungryul;Choi, Myoung-Hwan;Kim, Kwangsoo;Senok, Solomon S.;Cho, Dong-il Dan;Koo, Kyo-in;Goo, Yongsook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제21권5호
    • /
    • pp.555-563
    • /
    • 2017
  • Electrical stimulation through retinal prosthesis elicits both short and long-latency retinal ganglion cell (RGC) spikes. Because the short-latency RGC spike is usually obscured by electrical stimulus artifact, it is very important to isolate spike from stimulus artifact. Previously, we showed that topographic prominence (TP) discriminator based algorithm is valid and useful for artifact subtraction. In this study, we compared the performance of forward backward (FB) filter only vs. TP-adopted FB filter for artifact subtraction. From the extracted retinae of rd1 mice, we recorded RGC spikes with $8{\times}8$ multielectrode array (MEA). The recorded signals were classified into four groups by distances between the stimulation and recording electrodes on MEA (200-400, 400-600, 600-800, $800-1000{\mu}m$). Fifty cathodic phase-$1^{st}$ biphasic current pulses (duration $500{\mu}s$, intensity 5, 10, 20, 30, 40, 50, $60{\mu}A$) were applied at every 1 sec. We compared false positive error and false negative error in FB filter and TP-adopted FB filter. By implementing TP-adopted FB filter, short-latency spike can be detected better regarding sensitivity and specificity for detecting spikes regardless of the strength of stimulus and the distance between stimulus and recording electrodes.