• Title/Summary/Keyword: Crest Factor

Search Result 112, Processing Time 0.023 seconds

On the Phase Sequence Set of SLM Scheme for Crest Factor Reduction in OFDM System (OFDM 시스템의 Crest 값을 감소하기 위한 SLM 기법의 위상 시퀀스에 관한 연구)

  • Lim Dae-Woon;Heo Seok-Joong;No Jong-Seon;Chung Ha-Bong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9C
    • /
    • pp.889-896
    • /
    • 2006
  • The crest factor distribution of orthogonal frequency division multiplexing (OFDM) symbol sequences is evaluated and it is shown that OFDM symbol sequences with a short period are expected to have a high crest factor. The crest factor relationship between two input symbol sequences, Hamming distance D apart is also derived. Using these two results, we propose two criteria for a phase sequence set of the selected mapping (SLM) scheme and suggest the rows of the cyclic Hadamard matrix constructed from an m-sequence as the near optimal phase sequence set of the SLM scheme.

Novel Crest Factor Improvement of Electronic Ballast-Fed Fluorescent Lamp Current Using Pulse Frequency Modulation

  • Song Joong-Ho;Choy Ick;Choi Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.98-103
    • /
    • 2001
  • In case that electronic ballast employing a valley-fill passive power factor correction (PFC) circuit is used for feeding fluorescent lamps, a new method to reduce crest factor of the lamp current is studied in this paper. In order to reduce crest factor to lower value, a pulse frequency modulation technique based on the waveform of the dc-link voltage which is predetermined by the passive PFC circuit, is taken into the switching control action of the electronic ballast. An equation-based analysis between the crest factor of lamp current and the effect of varying the inverter switching frequency is comprehensively performed.

  • PDF

Crest Factors of 16-QAM Modulated Multicode MC-CDMA Signals Employing Complementary Sequences (이진 상보형 수열 쌍을 대역확산 부호로 사용하고 16-QAM 변조 기법을 이용한 MC-CDMA 신호의 전력 포락선 특성 분석)

  • Choi Byoung-Jo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9C
    • /
    • pp.817-824
    • /
    • 2006
  • The crest factor properties of 16-QAM modulated one- and two-code assisted multi-carrier code-division multiple-access (MC-CDMA) signals employing complementary pair as spreading sequences are characterized. It is shown that a set of relationship between the two 16-QAM symbols entirely characterize the power envelope waveforms of the signals. There exists 60 different sets of relationship, which results in 16 different crest factors as a result of various equivalent transforms on the corresponding message symbols. It is also shown that the individual crest factor corresponding to each message combination is always bounded by 3dB.

Crest Factor Reduction of Electronic Ballast for Fluorescent Lamps Using Pulse Frequency Modulation Control (펄스 주파수 변조 기법을 이용한 형광등 안정기의 파고율(Crest Factor) 저감 기법)

  • Song, Joo-Ho;Lee, Dong-Yun;Song, Joong-Ho;Choi, Ju-Yeop;Choy, Ick;Lim, Myo-Taeg
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2559-2561
    • /
    • 1999
  • The life of a fluorescent lamp is greatly affected by starting scenario and crest factor. This paper will propose a new crest factor control method in electronic ballast for fluorescent lamp using Pulse Frequency Modulation (PFM), which employs a passive Power Factor Correction (PFC) circuit in the input stage. The operation of parellel-loaded circuit, the switching frequency. and the characteristics of electronic ballast with the proposed PFM control scheme are described in detail, and its validity is verified by the simulation results.

  • PDF

Impulsive sound localization using crest factor of the time-domain beamformer output (빔형성기 출력의 파고율을 이용한 충격음의 방향 추정)

  • Seo, Dae-Hoon;Choi, Jung-Woo;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.713-717
    • /
    • 2014
  • This paper presents a beamforming technique for locating impulsive sound source. The conventional frequency-domain beamformer is advantageous for localizing noise sources for a certain frequency band of concern, but the existence of many frequency components in the wide-band spectrum of impulsive noise makes the beamforming image less clear. In contrast to a frequency-domain beamformer, it has been reported that a time-domain beamformer can be better suited for transient signals. Although both frequency- and time-domain beamformers produce the same result for the beamforming power, which is defined as the RMS value of its output, we can use alternative directional estimators such as the peak value and crest factor to enhance the performance of a time-domain beamformer. In this study, the performance of three different directional estimators, the peak, crest factor and RMS output values, are investigated and compared with the incoherent interfering noise embedded in multiple microphone signals. The proposed formula is verified via experiments in an anechoic chamber using a uniformly spaced linear array. The results show that the peak estimation of beamformer output determines the location with better spatial resolution and a lower side lobe level than crest factor and RMS estimation in noise free condition, but it is possible to accurately estimate the direction of the impulsive sound source using crest factor estimation in noisy environment with stationary interfering noise.

  • PDF

A New Control Scheme of Class-E Electronic Ballast with Low Crest Factor

  • Chon, Hyun-Son;Lee, Dong-Yun;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.175-184
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for reducing the crest factor of electronic ballasts for fluorescent lamps using Pulse-Frequency-Modulation (PFM) is Introduced The lifetime of the lamps is guaranteed by decreasing the lamp crest factor and also voltage stress of the switch is significantly decreased by a new scheme although conventional Class-E Inverter is used In this paper. The proposed PFM control scheme didn't use any auxiliary circuit. The proposed control strategy is executed by feeding back the Input voltage, and the zero-voltage-switching (ZVS) is ensured by maintaining constant turn-off time of the switch Therefore, the control principles of proposed method are explained in detail and its validity is verified through several simulations and experimental results.

A second order analytical solution of focused wave group interacting with a vertical wall

  • Sun, Yonggang;Zhang, Xiantao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.2
    • /
    • pp.160-176
    • /
    • 2017
  • The interaction of focused wave groups with a vertical wall is investigated based on the second order potential theory. The NewWave theory, which represents the most probable surface elevation under a large crest, is adopted. The analytical solutions of the surface elevation, velocity potential and wave force exerted on the vertical wall are derived, up to the second order. Then, a parametric study is made on the interaction between nonlinear focused wave groups and a vertical wall by considering the effects of angles of incidence, wave steepness, focal positions, water depth, frequency bandwidth and the peak lifting factor. Results show that the wave force on the vertical wall for obliquely-incident wave groups is larger than that for normally-incident waves. The normalized peak crest of wave forces reduces with the increase of wave steepness. With the increase of the distance of focal positions from the vertical wall, the peak crest of surface elevation, although fluctuates, decreases gradually. Both the normalized peak crest and adjacent crest and trough of wave forces become larger for shallower water depth. For focused wave groups reflected by a vertical wall, the frequency bandwidth has little effects on the peak crest of wave elevation or forces, but the adjacent crest and trough become smaller for larger frequency bandwidth. There is no significant change of the peak crest and adjacent trough of surface elevation and wave forces for variation of the peak lifting factor. However, the adjacent crest increases with the increase of the peak lifting factor.

A Study on Crest Settlement Characteristics of Rockfill Dam (락필댐의 정부침하 거동특성 연구)

  • Park, Han-Gue;Park, Dong-Soon;Kim, Yong-Seong;Lee, Jong-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1219-1226
    • /
    • 2005
  • In this study, crest settlement characteristics of CFRD (Concrete Faced Rockfill Dam) and ECRD (Earth Cored Rockfill Dam) were analysed through the instrumentation data from representative 7 large dams in Korea. Also, We have studied the effect of valley shape and uniaxial compressive strength of intact rock to better understand the impact of the parent rock strength and the valley shape on the long term crest settlement of CFRDs. From the results, we found that the valley shape and strength of intact rock on crest settlement of dams are an important parameters. As a result, we obtained that the maximum crest settlement of CFRD is larger than that of ECRD and long term crest settlement rate per dam height of rockfill dams is less than 0.60% during service period.

  • PDF

Analysis of the Leakage Impulse Current in Faulty Insulators for Detection of Incipient Failures (절연물의 초기사고 감지를 위한 누설 임펄스 전류의 해석)

  • Kim, Chang-Jong;Lee, Heung-Jae;Sin, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.390-398
    • /
    • 2000
  • Leakage impulse current of the contaminated insulators by using experiment data were studied. The impulse current in phase-time relationship was analyzed on line post insulators. Also, frequency components and crest factor of the leakage current were investigated to provide a scheme for an early detection of insulator incipient failure. The study shows that the phase-time characteristic is non-stationary and random and, non-harmonic component and crest factor can be promising parameters for detecting insulator leakage currents.

  • PDF

A new control scheme of Class-E electronic Ballast with low crest factor (저 파고율 특성을 갖는 Class-E 전자식 안정기의 새로운 제어 기법)

  • Chon, Hyun-Son;Lee, Dong-Yun;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.234-236
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for reducing the crest factor of electronic ballasts for fluorescent lamps using Pulse-Frequency-Modulation (PFM) is introduced The lifetime of the lamps is guaranteed by decreasing the lamp crest factor and voltage stress of the switch is significantly decreased by a new scheme although conventional Class-E inverter is used in this paper The proposed PFM control scheme doesn't used any auxiliary circuit. The proposed control strategy is executed by feeding back the input current. and the Zero-Voltage-Switching (ZVS) is ensured by operating beyond resonant frequency. Therefore, the control principles of proposed method are explained in detail and its validity is verified through several simulated results.

  • PDF