• Title/Summary/Keyword: Cut off

Search Result 2,170, Processing Time 0.031 seconds

An Experimental Study on the Cut off Performance Test of Cut off Type Overflow Valve in L.P Gas (과류(過流) 차단형(遮斷型) 액화(液化) 석유(石油)가스 용기용(容器用) 밸브의 차단(遮斷) 성능(性能) 시험(試驗)에 관(關)한 실험적(實驗的) 연구(硏究))

  • LEE, JIN
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.116-122
    • /
    • 1992
  • The purpose of this paper is to determine the cut off flowrate regions of the overflow valve in using L.P gas vassels. The experimental methods were employed to measure the cut off flowrate in the state of constant pressure by using the $N_2$ gas. 1) To determine the optimum cut off flowrate regions, Hose length are required 0.5 meters. 2) Cut off fowrate regions about the each pressure can be suggested as follows. A) Cut off flowrate rigions are $2.0-4.0m^3/hr$ at the pressure of the $1Kg_f/cm^2$. B) Cut off flowrate rigions are$7.0-10.0m^3/hr$ at the pressure of the $10Kg_f/cm^2$.

  • PDF

The improvement of cut-off probe for measuring plasma density at hard conditions

  • Kim, Dae-Ung;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.202-202
    • /
    • 2011
  • Diagnostics of plasma density is a key factor for monitoring plasma processing. Various probes are invented to measure plasma density and cut-off probe is a one of the most promising diagnostics tool for measuring plasma density. However, at the low density or high pressure the cut-off probe cannot clearly resolve the cut-off peak. Several reasons make this problem: Cut-off likes peaks caused by cavity resonances and weaken transmission spectrum signal at high pressure. Recently, You et al., have researched mechanism of cut-off probe and we improve the cut-off reliability and sensitivity base on that research. Modified cut-off antenna is adapted and bias cut-off probe method is tried. These experiment results have good agreement with the previous study and show good measurement characteristics.

  • PDF

Association between False Positive, False Negative, High-Background Cases and Humidity in One Lambda LABTypeTM HLA-DR Typing (One Lambda LABTypeTM을 이용한 HLA- DR Typing시 나타나는 위양성과 위음성, High-Background 사례와 검사실 습도의 관계분석)

  • Hyang Son AN;Minsung SOHN
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.3
    • /
    • pp.132-142
    • /
    • 2023
  • Human leukocyte antigen (HLA) typing was performed in the diagnostic immunology laboratory of the Seoul National University Hospital. Among 611 HLA-DR tests, specific bead reactions suspected of being false positive and false negative in Lot 20 reagents were found. Therefore, we aimed to identify the factors causing cut-off corrections by examining cases where cut-off corrections were not made for 533 test results and cases where cut-off corrections were made for 78 cases after the cut-off corrections of specific beads. Frequency analysis was conducted to verify the demographic characteristics, and descriptive statistics were used to assess the humidity in the laboratory as a variable. Cross-tabulation was done to examine the association between cut-off corrections and demographic characteristics. Independent samples t-tests were conducted to verify the difference in humidity based on cut-off corrections. Finally, logistic regression analysis was conducted to examine the relationship between humidity levels and the rate of cut-off corrections, and results showed as the humidity level in the laboratory highs, the number of cut-off corrections decreased by a factor of 0.986. This suggests cut-off corrections rate increases when the humidity lowers. Therefore, it indicates that humidity in the laboratory is also a factor that affects HLA typing results.

Cut-off Probe Frequency Spectrum의 물리적 해석

  • Yu, Sin-Jae;Kim, Dae-Ung;Kim, Jeong-Hyeong;Seong, Dae-Jin;Sin, Yong-Hyeon;Na, Byeong-Geun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.200-200
    • /
    • 2011
  • Although the cut-off probe, a precise measurement method for the electron density, is widely used in the industry, the physics on the wave spectrum of the cut-off is not understood yet, only cut-off point frequency containing the information of electron density has been analyzed well. This paper analyzes the microwave frequency spectrum of the cut-off probe to see the physics behind using both microwave field simulation (CST Microwave Studio) and simplified circuit simulation. The result shows that the circuit model well reproduces the cut-off wave spectrum especially in the low frequency regime where the wavelength of the driving frequency is larger than the characteristic length and reveals the physics of transmission characteristics with frequency as resonances between vacuum, plasma and sheath. Furthermore, by controlling the time domain in solver of the microwave simulator, the cut-off like transmission peaks above the cut-off frequency which has been believed as cavity effect is verified as chamber geometry effect. The result of this paper can be used as the basis for the improvement of cut-off probe.

  • PDF

An experimental study for reduction of B.P.F. noise level of multi-blade fan (다익 송풍기의 이산 주파수 소음 저감을 위한 실험적 연구)

  • 김영찬;이상환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • B.P.F.(Blade Passing Frequency) levels were measured with the cut-off clearance changes. The velocity inside the scroll, pressure fluctuation at cut-off region, and the scroll surface pressure distribution along the scroll from the cut-off to outlet were measured. With a certain cut-off clearance the improvement of efficiency and attenuation of B.P.F. noise level could be achieved. The measured results of pressure fluctuation and scroll surface pressure distribution showed that the secondary flow inside the scroll increased B.P.F. noise level at the cut-off region as the cut-off clearance got wide.

  • PDF

Cut off Sampling and Estimation (절사법과 추정)

  • 한근식
    • Proceedings of the Korean Association for Survey Research Conference
    • /
    • 2003.06a
    • /
    • pp.29-33
    • /
    • 2003
  • In business survey. cut off sampling is usual. The contribution from cut off part of the population is at least small in comparison with the remaining population. In this study. the population have been separated as three stratum, cut-off. take-some, take-all, and we will estimate cut-off part.

  • PDF

Epidemiological Cut-off Values Generated for Disc Diffusion Data from Photobacterium damselae (Photobacterium damselae의 디스크 확산법 결과에 대한 Epidemiological Cut-off Value의 결정)

  • Kwon, Mun-Gyeong;Lim, Yun-Jin;Kim, Myoung-Sug;Seo, Jung-Soo;Kim, Do-Hyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.6
    • /
    • pp.838-844
    • /
    • 2016
  • In this study, epidemiological cut-off values were estimated for 44 Photobacterium damselae isolates, since clinical breakpoints have not been established for this pathogenic bacterium. The susceptibility of the isolates to 10 antibiotics was evaluated using internationally standardized disc diffusion protocols. Normalized resistance interpretation was used to generate statistically valid epidemiological cut-off values for the susceptibility data. There were not enough strains exhibiting full sensitivity to ampicillin and amoxicillin to allow analysis of these antibiotics. Because there were only a marginally sufficient number of strains exhibiting full sensitivity to oxytetracycline, the cut-off value generated provided only a provisional estimate. The valid wild-type cut-off values were <13, 13, 9, 22, 25, 27, and 28 mm for gentamicin, cephalexin, erythromycin, oxolinic acid, flumequine, florfenicol, and sulfamethoxazole/trimethoprim, respectively. The application of these cut-off values should greatly facilitate the rational selection of antibiotics for use in commercial fish farms.

A study of Full Width at Half Maximum(FWHM) according to the Filter's Cut off level in SPECT camera (SPECT filter의 cut off level에 따른 반폭치(FWHM) 크기에 관한 연구)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.63-69
    • /
    • 2003
  • Filtering is necessary to reduce statistical noise and to increase image quality in SPECT images. Noises controled by low-pass filter designed to suppress high spatial frequency in SPECT image. Most SPECT filter function control the degree of high frequency supression by chosing a cut of frequency. The location of cut off frequency determines the affect image noise and spatial resolution. If select the low cut off frequency, its provide good noise suppression but insufficient image quantity and high cut off frequencies increase the image resolution but insufficient noise suppression. The purpose of this study was to determines the optimam cut off level with comparison of FWHM according to cut off level in each kiters-Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen and Butterworth filter in SPECT camera. We recorded image along the X, Y, Z-axis with $^{99m}TcO_4$ point source and measured FWHM by use profile curve. We find averaged length is $9.16\;mm{\sim}18.14\;mm$ of FWHM in X, Y, and Z-axis, and Band-limited and Generalized Hamming filters measures 9.16 mm at 0.7 cycle/pixel cut off frequency.

  • PDF

Should Cut-Off Values of the Risk of Malignancy Index be Changed for Evaluation of Adnexal Masses in Asian and Pacific Populations?

  • Yavuzcan, Ali;Caglar, Mete;Ozgu, Emre;Ustun, Yusuf;Dilbaz, Serdar;Ozdemir, Ismail;Yildiz, Elif;Gungor, Tayfun;Kumru, Selahattin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5455-5459
    • /
    • 2013
  • Background: The risk of malignancy index (RMI) for the evaluation of adnexal masses is a sensitive tool in certain populations. The best cut off value for RMI 1, 2 and 3 is 200. The cut off value of RMI-4 to differentiate benign from malignant lesions is 450. Our aim was to evaluate the efficiency of four different malignancy indexes (RMI1-4) in a homogeneous population. Materials and Methods: We evaluated a total of 153 non-pregnant women with adnexal masses who did not have a history of malignancy and who were above 18 years of age. Results: A cut-off value of 250 for RMI-1 provided 95.9% inter-observer agreement, yielding 95.9% specificity, 93.5% negative predictive value, 75.0% sensitivity and 82.8% positive predictive value. A cut-off value of 250 for RMI-1 showed high performance in preoperative diagnosis of invasive malignant lesions than cut-off value of 200 in our population. A cut-off value of 350 for RMI-2 provided 94.5% inter-observed agreement, yielding 94.2% specificity, 93.4% negative predictive value, 75.0% sensitivity and 77.4% positive predictive value. RMI-2 showed the higher performance when the cut-off value was set at 350 in our population. A cut-off value of 250 provided 95.2% inter-observer agreement, yielding 95.0% specificity, 93.2% negative predictive value, 75.0% sensitivity, and 88.0% positive predictive value. RMI-3 showed the highest performance to diagnose malignant adnexal masses when the cut-off value was set at 250. In our study, RMI-4 showed similar statistical performance when the cut-off value was set at 400 [(Kappa: 0.684/p=0.000), yielding 93.8% inter-observer agreement, 93.4% specificity, 93.4% negative predictive value, 75.0% sensitivity, and 75.0% negative predictive value]. Conclusions: We showed successful utilization of RMIs in preoperative differentiation of benign from malignant masses. Many studies conducted in Asian and Pacific countries have reported different cut-off values as was the case in our study. We think that it is difficult to determine universally accepted cut-off values for RMIs for common use around the globe.

Effect of Cut-off Intervals on Nutrients Removal Efficiency in Hydrophytes at the Artificial Vegetation Island (인공수초재배섬에서 수생식물 지상부 절취주기별 수중영양염류 제거효율)

  • Park, Hae-Kyung;Byeon, Myeong-Seop;Choi, Myung-Jae;Yun, Seok-Hwan;Jeon, Nam-Hui
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.221-226
    • /
    • 2009
  • We investigated the most effective cutting interval for underwater nutrient removal through cut off the emergent part of hydrophytes at artificial vegetation island (AVR) which was installed for the purpose of water quality improvement in Lake Paldang. We divided the planting area of Phragmites japonica into three parts according to the cutting intervals. The shoot height and relative growth rate of P. japonica, nutrient contents and biomass of cut off P. japonica were measured at each cutting interval. The amount of nutrients which were removed through cut off at each cutting interval was calculated. P. japonica showed full growth, 80% and 60% of full growth before first cut off at three-months, two-months and one-month cutting interval condition respectively. Three-month cutting interval condition showed the largest biomass of cut off P. japonica and one-month cutting interval condition showed the least. However the cut off P. japonica showed the highest content of nutrients at one-month cutting interval condition and the least at three-month cutting interval condition. The amount of phosphorus and nitrogen removal at two-month cutting off condition is the largest among three cutting interval conditions indicating that cut off the emergent part of P. japonica every two months is the most effective to remove the nutrients from water at AVR in eutrophic lakes.