• Title/Summary/Keyword: Disc method

Search Result 1,016, Processing Time 0.024 seconds

Two Cases on Tortipelvis caused by Lumbar Disc Herniation - Using Mckenzie Method Treatment (요추 추간판 탈출증에 의한 골반경사 치험 2례 - Mckenzie 수기요법을 이용)

  • Hwang, Hyung-Joo;Heo, Kwang-Ho;Keum, Dong-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.2 no.1
    • /
    • pp.85-97
    • /
    • 2007
  • Objectives : We evaluated the effect of Mckenzie method treatment by participating two patients suffering from Tortipelvis by lumbar disc herniation. Methods : Two patients were diagnosed as Tortipelvis by lumbar disc herniation through CT scan and X-ray examination. We used Mckenzie method and measured VAS(Visual analogue scale). Results and Conclusions : After using Mckenzie method treatment, We found out a recovery from both patients suffering from Tortipelvis by lumbar disc herniation. The result, through our study, suggests that Mckenzie method treatment was effective to cure the Tortipelvis by lumbar disc herniation. It also was effective to reduce the low back pain and to stabilize the lumbar disc herniation.

  • PDF

Optimization of an Automotive Disc Brake Cross-section with Least Thermal Deformation by Taguchi Method (최소 열변형을 위한 자동차 디스크 브레이크 단면형상의 다구찌기법 기반 최적설계)

  • Kim, Cheol;Ha, Tae-jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Optimum cross-sectional shape of an automotive disc brake was developed based on FEM thermal analyses and the Taguchi method. Frictional heat flux and convection heat transfer coefficients were first calculated using equations and applied to the disc to calculate accurate temperature distribution and thermal deformations under realistic braking conditions. Maximum stress was generated in an area with highest temperature under pads and near the hat of ventilated disc and vanes. The SN ratio from Taguchi method and MINITAB was applied to obtain the optimum cross-sectional design of a disc brake on the basis of thermal deformations. The optimum cross-section of a disc can reduce thermal deformation by 15.2 % compared to the initial design.

Relation between the DISC Behavior, Coping Type and Level of Stress and Job Satisfaction, Organizational Committment of Hospital Employees (병원 종사자의 DISC 행동유형 및 스트레스 대처유형과 직무만족, 직무몰입 간의 관계)

  • Bang, Kih-Hyeon;Jang, Hyo-Kang;Jung, Yong-Mo
    • Korea Journal of Hospital Management
    • /
    • v.15 no.3
    • /
    • pp.17-32
    • /
    • 2010
  • The purpose of this study is to analyze the influence of DISC behavior pattern, stress-managing method, and the stress level on job attitude of hospital Employees, and to provide suggestions for effective human resources management in hospital settings. First, the research suggested emotional or aversive stress-managing method had significant influence to the stress level, whereas DISC behavior patterns did not. Second, to the job satisfaction, Influence, Compliance and Steadiness of DISC behavior patterns, challenging or aversive stress-managing method, and the stress level showed immediate meaningful effect. Third, for the system immersion, challenging or emotional ress-managing method as well as the job satisfaction showed direct influence. Especially, the challenging method had not only a direct but an indirect effect through mediating job satisfaction.

  • PDF

Monitoring Method of Projecting Disc in Optical Archive System (아카이브 정보저장기기에서의 디스크 돌출 모니터링 기술)

  • Jeong, Wooyoung;Lim, Sung-Yong;Yang, Hyunseok;Yoo, SeungHon
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • Optical Archive system consists of cartridge, drive and transfer robot. Transfer robot moves disc in cartridge to drive that reads data of disc. Distance between disc in cartridge and transfer robot very short, about 4mm. When disc projects, there is a danger of collision. Collision can cause breakage of disc and breakdown of system. To prevent collision of disc and transfer robot, projection of disc should be detected. In this paper, we proposed error monitoring method of projecting disc in archive data storage using camera. Proposed algorithm is evaluated by experiments with archive system.

An Analysis of the State of Cervical Disc Herniation According to Cervical Lordosis and Age (경추 전만 정도 및 연령에 따른 경추 추간판 탈출 양상 분석 연구)

  • Lim, Ji Seok;Yoon, Kang Hyun;Lee, Seungmin;Cho, Ye Eun;Park, Ji Min;Lee, Sang Hoon;Kim, Yong Suk
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.107-115
    • /
    • 2015
  • Objectives : The aim of this study is to investigate the state of cervical disc herniation according to the degree of cervical lordosis and age. Methods : 67 records of inpatients who were diagnosed with herniated intervertebral disc(HIVD) of the cervical spine were analyzed. Cobb's method, Jochumsen method and the Ishihara index were used to measure the degree of cervical lordosis. The state of the cervical disc was identified using magnetic resonance imaging(MRI) of the cervical spine. Then correlations among cervical lordosis, age and cervical disc herniation were analyzed. Results : Disc bulging was associated with hypolordosis and disc protrusion was associated with hyperlordosis and age. Disc extrusion was not associated with either cervical lordosis or age. The number of disc herniations in the cervical spine was correlated with age significantly, but not with cervical lordosis. Conclusions : Cervical disc herniation had a tendency to correlate with age and cervical lordosis, although this is not definite. Future studies that analyze more radiographic images of patients with HIVD of the cervical spine might be necessary to identify the influence of cervical lordosis on cervical disc herniation.

Prediction of Load-displacement of the Disc Spring with the Friction (마찰을 고려한 접시 스프링의 하중 변위 곡선 예측)

  • Shin, Dong-Ho;Lee, Jung-Youn;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.4
    • /
    • pp.344-351
    • /
    • 2012
  • A disc spring consists of a conical disc. A load-displacement formula was newly developed in the form of energy method to consider both rigid and friction. The cross section of the disc spring has identical slope angles at the bottom of conical. To solve such a problem, an energy method calculation is proposed. To achieve the goal of this study, the proposed calculation is extended to a disc spring with friction. A firm basis background study based on Almen's work is presented in developing a new numerical approach to predict the available formulation for a disc spring with friction.

Prediction of Load-Displacement of the Disc Spring with the Friction (마찰을 고려한 접시 스프링의 하중 변위 곡선 예측)

  • Shin, Dong-Ho;Oh, Jae-Eung;Lee, Jung-Youn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.572-577
    • /
    • 2011
  • A disc spring consists of a conical disc. A load-displacement formula was newly developed in the form of energy method to consider both rigid and friction. The cross section of the disc spring has identical slope angles at the bottom of conical. To solve such a problem, an energy method calculation is proposed. To achieve the goal of this study, the proposed calculation is extended to a disc spring with friction. A firm basis background study based on Almen's work is presented in developing a new numerical approach to predict the available formulation for a disc spring with friction.

  • PDF

A Study of Estimation of Lumbar Intervertebral Disc Size by Colombini's Method (Colombini 방법에 의한 요추부 추간판 크기 추정에 관한 연구)

  • Kim, Jong-Soon
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.1
    • /
    • pp.23-31
    • /
    • 2007
  • Purpose: As a preliminary study, the purpose of this study was to examine the indirect estimation of the lumbar intervertebral disc size by two anthropometric methods, in order to compare these indirect methods with the direct analysis by radiological imaging. Methods: The wrist, elbow, knee, and ankle joint (both right and left) diameters were measured in 52 volunteers, and then intervertebral disc size was calculated using two anthropometric methods (Colombini and modified Colombini). The data were analysed with independent t-test to assess clinical usefulness. Results: When using right and left joint diameter, there was no significant difference in the estimation value of the L4-5 and L5-S1 intervetebral disc sizes. However, the study has shown that male subjects have significantly larger L4-5 and L5-S1 intervertebral disc sizes, compared with those of female subjects. In addition, disc sizes calculated by Colombini's formula were significantly larger than modified Colombini's formula. Conclusion: The indirect estimation of the intervertebral disc size by anthropometric method can be considered as a clinically useful method. However, further study should be conducted to compare anthropometric values with other radiological imaging.

  • PDF

Implement and Verification of the Algorithm of the Optical Disc Detection Using the Side-beams (사이드 빔을 이용한 광디스크 판별 알고리즘의 구현 및 검증)

  • 임선미;허준호;추철환;임종철;김태성;김수원
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2669-2672
    • /
    • 2003
  • This paper describes a new method of discrimination between the normal disc and the rewritable one. The conventional method of disc discrimination, using Focus error signal, has a heavy fluctuations. To achieve an accurate discrimination, in this paper, the sum of side beam[1]signal is used for that. A new approach is expected to improve the performance of disc discrimination as well as to reduce the signal variation almost by 50%. Techniques in this paper are applicable to the all types of optical disc player, such as CD (compact disc), VCD(Video-CD) and DVD (digital versatile disc) and any other optical disc players.

  • PDF

Acoustic field simulation of a PZT4 disc projector using a coupled FE-BE method

  • Jarng, S.S.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.211-218
    • /
    • 1999
  • This paper describes the application of a coupled finite element-boundary element method (FE-BEM) to obtain the steady-state response of a piezoelectric transducer. The particular structure considered is a PZT4 disc-typed projector. The projector is three-dimensionally simulated to transduce applied electric charge on axial surfaces of the piezoelectric disc to acoustic pressure in air or in water. The directivity pattern of the acoustic field formed from the projected sound pressure is also simulated. And the displacement of the disc caused by the externally applied electric charge is shown in temporal motion. The coupled FE-BE method is described in detail.

  • PDF