• 제목/요약/키워드: FRP reinforcement

검색결과 295건 처리시간 0.02초

FRP Rods로 보강한 콘크리트 보의 전단 내하력의 평가 (Estimation of Shear Carrying Capacity on Concrete Beams, Reinforced with FRP Rods)

  • 최익창;연준희;고재용
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2004
  • The purpose of this study is to estimate the contribution of concrete and shear reinforcement, in shear carrying capacity, on concrete beams, reinforced with steel and/or FRP rods. The experimental tests for 12 concrete beams, reinforced with steel and/or FRP rods, are carried out. Experimental parameters includes the mechanical properties of reinforcements in shear and bending, and the ratio of shear reinforcement. This study compares the experimental results of shear carrying capacity in concrete beams, reinforced with steel and/or FRP rods, with the proposed equations. According to the experimental results, the effect of the concrete in concrete beams reinforced with FRP rods is decreased with decreasing Young's modulus of longitudinal tensile reinforcement. This results from the large deflection of concrete beams reinforced with decreasing Young's modulus of longitudinal tensile reinforcement. Also, the contribution of shear reinforcement is smaller than the calculated value, using the truss analogy. This results from the fact that the stress redistribution is not exhibited after the break of shear reinforcement.

콘크리트 환경과 고온의 복합환경이 FRP 보강근의 계면전단성능에 미치는 영향 (The Combined Effect of Concrete Environment and High Temperature on Interlaminar Shear Strength of FRP Reinforcement)

  • 문도영;오홍섭
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.749-756
    • /
    • 2011
  • FRP 보강근의 화재 노출시 내구성능에 대한 연구들은 고온 노출이 인장성능에 미치는 영향에 대한 분석이 대부분을 차지한다. 그러나, 신설 구조물에 삽입된 FRP 보강근은 먼저 콘크리트 내에서 습윤환경 및 알칼리에 의한 성능저하가 발생하며, 이와 같은 FRP 보강 콘크리트 구조물에 화재가 발생하면, 보강근은 고온에 노출된다. 그러므로 화재에 의해 손상 받은 FRP 보강근의 평가시에는 콘크리트 환경과 고온에 의한 영향을 동시에 고려하여야 한다. 이 연구에서는 장기간동안 용액에 노출된 FRP 보강근에 $60^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$$300^{\circ}C$의 온도를 가하고, 계면전단강도를 측정, 비교 하였다. 실험 결과에 따르면, 환경과 고온의 복합영향이 FRP 보강근의 역학적 특성에 미치는 영향이 환경만의 영향 또는 고온만의 영향 보다 큰 것으로 나타났다.

Assessment of reliability-based FRP reinforcement ratio for concrete structures with recycled coarse aggregate

  • Ju, Minkwan;Park, Kyoungsoo;Lee, Kihong;Ahn, Ki Yong;Sim, Jongsung
    • Structural Engineering and Mechanics
    • /
    • 제69권4호
    • /
    • pp.399-405
    • /
    • 2019
  • The present study assessed the reliability-based reinforcement ratio of FRP reinforced concrete structure applying recycled coarse aggregate (RCA) concrete. The statistical characteristics of FRP bars and RCA concrete were investigated from the previous literatures and the mean value and standard deviation were employed for the reliability analysis. The statistics can be regarded as the material uncertainty for configuring the probability distribution model. The target bridge structure is the railway bridge with double T-beam section. The replacement ratios of RCA were 0%, 30%, 50%, and 100%. From the probability distribution analysis, the reliability-based reinforcement ratios of FRP bars were assessed with four cases according to the replacement ratio of RCA. The reinforcement ratio of FRP bars at RCA 100% showed about 17.3% higher than the RCA 0%, where the compressive strength at RCA 100% decreased up to 27.5% than RCA 0%. It was found that the decreased effect of the compressive strength of RCA concrete could be compensated with increase of the reinforcement ratio of FRP bars. This relationship obtained by the reliability analysis can be utilized as a useful information in structural design for FRP bar reinforced concrete structures applying RCA concrete.

Hybrid Reinforcement System을 이용한 콘크리트 교량상판 슬래브의 거동 (Behavior of Concrete Bridge Deck Using Hybrid Reinforcement System)

  • 박상렬;조근희
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.451-458
    • /
    • 2004
  • 본 연구는 재래 철근과 Fiber Reinforced Polymer 보강재를 사용한 Hybrid Reinforcement System의 기본 개념과 적용성에 대해 기술하고 있다. 콘크리트 교량상관은 보로서 지지되고 상하 두층의 보강재로 인장보강되어 있다. HRS를 이용한 콘크리트 교량상판에서는 보 지지점 부근의 부모멘트에 대한 상부 인장력은 FRP 봉으로 저항하고 보 지지점 중앙부근의 하부인장력은 재래의 철근으로 저항한다. HRS를 이용한 콘크리트 교량상판은 FRP 봉은 비 부식성이고, 부식되기 쉬운 철근은 교량상판 위로부터 가급적 멀리하여 부식물질의 침투를 막을 수 있는 장점이 있다. HRS를 이용한 콘크리트 교량상판은 또한 극한상태에서 충분한 연성을 가지고 있다. 그 이유는 1) FRP봉은 철근보다 탄성계수가 낮고 파단시의 최대 변형률이 크며, 2) 충분한 FRP 보강량을 사용하면 극한변형률을 낮출 수 있으며, 3) 부모멘트 구간의 일부를 비부착시켜 극한 변형률을 낮출 수 있다. 실험 연구 결과 보통의 FRP보강비의 범위에서는 FRP 및 HRS 콘크리트 슬래브는 FRP봉의 파단이 아니라 콘크리트의 압축에 의해 파피됨을 보여주고 있다. 그러므로 HRS를 이용한 연속 콘크리트 교량상관에서는 정모멘트부의 하부철근이 먼저 항복하여 소성힌지를 형성하고 나중에 부보멘트나 정모멘트부의 콘크리트가 압축파괴되어 FRP 콘크리트 슬래브에 비하여 상당한 소성에너지를 소모한다.

FRP 판을 거푸집 및 보강재로 활용한 콘크리트 보의 실험적 연구 (Experimental Study of Concrete Beam with FRP Plank as Formwork and Reinforcement)

  • 유승운;배한욱
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.67-74
    • /
    • 2007
  • FRP 판을 콘크리트 구조물의 거푸집 및 보강재로 이용하기 위한 기본적인 실험을 수행하였다. FRP 판과 콘크리트가 합성 효과를 발휘하기 위해서는 두 재료간의 부착이 중요한 요인 중의 하나이다. 이러한 부착을 확보하기 위하여 FRP 판에 두 가지 크기의 골재를 일반적으로 건설 현장에서 많이 사용하는 에폭시를 이용하여 부착 하였다. 콘크리트 보는 FRP 판만으로 인장 보강하였고 추가적인 휨 및 전단 보강은 하지 않았다. 비교를 위해 한 비교 실험 시편은 FRP 판에 골재를 부착하지 않고, 다른 한 비교 실험 시편은 FRP 판 대신에 종래의 철근으로 보강하여 실험하였다. 모든 콘크리트 보의 실험은 보의 중앙에 집중하중을 파괴까지 재하하였다. 실험 결과는 현행 ACI 318(2005)과 ACI 440(2006)과 비교 분석하였다. 본 연구 결과 FRP 판을 콘크리트 구조물의 거푸집 대용 및 인장 보강재로 충분히 활용할 수 있는 가능성을 보여주었다.

구조물 보강용 FRP 판과 광섬유 센서가 결합된 자기감지 보강재 (Self Sensing Reinforcement Combined with Fiber-Optic Sensor and FRP Strip for Structural Reinforcement)

  • 송세기;서수연;김강수
    • 대한건축학회논문집:구조계
    • /
    • 제35권8호
    • /
    • pp.123-130
    • /
    • 2019
  • Recently, it is required to develop a monitoring technology that combines an FBG sensor as a means for continuously monitoring whether reinforcing effect of FRP is maintained on FRP reinforced structural members. However, most existing researches focus on the insertion of FBG sensors into bar-shaped FRPs, and there is insufficient study on the details strip-type FRPs combined with FBG sensors. Therefore, in this paper, it is studied to develop a reinforcement in which a FBG sensor is combined with a FRP strip. Especially, combination of FRP and FBG sensor. For this, a series of experiments were performed to find the adhesive strength of fiber-FRP-epoxy joints, the tensile strength of FBG sensor part with reflection-lattice, and the performance depending on the connection method of FRF and FBG sensor. As a result of the study, it was found that a minimum strength of $216.15N/mm^2$ is required for incorporating FBG sensors in FRP using epoxy. It is considered that the adhesion length of epoxy joints should be more than 50mm. When the FBG sensor is attached to the FRP strip as an epoxy, it is considered appropriate to use the complete attachment and the sensor non-attachment method.

퍼포본드 FRP-콘크리트 합성보의 실험적 연구 (An Experimental Study of Perfobond FRP-Concrete Composite Beam)

  • 유승운;국무성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.121-127
    • /
    • 2010
  • 퍼포본드 FRP 판을 영구 거푸집 및 인장 보강재로 이용한 합성보에 대한 실험을 수행하였다. FRP 판을 영구 거푸집 및 인장 보강재의 합성이용은 재래적인 방법에서 필요한 거푸집 조립 및 탈형 등의 작업이 수반되지 않으므로 빠른 시공이 가능하다. FRP 판과 콘크리트가 합성 구조체로 작용하기 위해서는 FRP 판의 표면처리가 필요하다. 이를 위해 FRP 판에 잔골재를 현장에서 많이 사용하는 에폭시를 이용하여 부착하고 FRP 판의 웨브에 구멍을 천공하였다. 합성보에 추가적인 휨 및 전단보강은 하지 않았다. 비교를 위해 두가지 종류의 비교 실험시편을 제작하였다. FRP 판의 웨브에 구멍을 천공하지 않은 비교 실험시편과 FRP 판 대신에 철근으로 보강한 비교 실험시편이다. 모든 시험체는 중앙에 집중하중을 재하하여 파괴까지 실험하였다. 본 연구 결과 퍼포본드 FRP 판은 콘크리트 구조물의 영구 거푸집 대용 및 인장 보강재로도 활용 할 수 있는 가능성을 보여주었다.

하이브리드 FRP 리바의 역학적 특성 (Mechanical Properties of Hybrid FRP Rebar)

  • 박찬기;원종필
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.58-67
    • /
    • 2003
  • Over the last decade fiber-reinforced polymer (FRP) reinforcement consisting of glass, carbon, or aramid fibers embedded in a resin such as vinyl ester, epoxy, or polyester has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. But reinforcing rebar for concrete made of FRP rebar has linear elastic behavior up to tensile failure. For safety a certain plastic strain and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. The same should be required for FRP rebar. Thus, the main object of this study was to develop new type of hybrid FRP rebar Also, this study was evaluated to the mechanical properties of Hybrid FRP rebar. The Manufacture of the hybrid FRP rebar was achieved by pultrusion, and braiding and filament winding techniques. Tensile and interlaminar shear test results of Hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

Behavior of FRP-reinforced steel plate shear walls with various reinforcement designs

  • Seddighi, Mehdi;Barkhordari, Mohammad A.;Hosseinzadeh, S.A.A.
    • Steel and Composite Structures
    • /
    • 제33권5호
    • /
    • pp.729-746
    • /
    • 2019
  • The nonlinear behavior of single- and multi-story steel plate shear walls (SPSWs) strengthened with three different patterns of fiber reinforced polymer (FRP) laminates (including single-strip, multi-strip and fully FRP-strengthened models) is studied using the finite element analysis. In the research, the effects of orientation, width, thickness and type (glass or carbon) of FRP sheets as well as the system aspect ratio and height are investigated. Results show that, despite an increase in the system strength using FRP sheets, ductility of reinforced SPSWs is decreased due to the delay in the initiation of yielding in the infill wall, while their initial stiffness does not change significantly. The content/type/reinforcement pattern of FRPs does affect the nonlinear behavior characteristics and also the mode and pattern of failure. In the case of multi-strip and fully FRP-strengthened models, the use of FPR sheets almost along the direction of the infill wall tension fields can maximize the effectiveness of reinforcement. In the case of single-strip pattern, the effectiveness of reinforcement is decreased for larger aspect ratios. Moreover, a relatively simplified and approximate theoretical procedure for estimating the strength of SPSWs reinforced with different patterns of FRP laminates is presented and compared with the analytical results.

긴급시공이 가능한 FRP 내진보강재 개발 및 최적 보강량 산정을 위한 해석적 연구 (Analytical Study for Optimal Reinforcement Amount and Development of FRP Seismic Reinforcement that can be Emergency Construction)

  • 김진섭;권민호;서현수;임정희;김동영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권5호
    • /
    • pp.136-145
    • /
    • 2013
  • 최근 발생한 대규모 지진으로 구조물의 내진보강에 대한 사회적 관심도가 높아지고 있다. 특히 내진 설계가 반영되지 않은 기둥은 취성적인 파괴로 구조물 전체붕괴를 유발하기 때문에 내진보강이 적용 되어야한다. 과거에는 단면증설법, 강판보강법등이 주로 적용되었고 최근에는 복합재료의 장점을 이용한 섬유보강법이 선호되고 있다. 그러나 이러한 보강법들은 구조물의 물리적 손상을 유발하며, 작업공간과 시간소비가 크다는 단점이 있다. 본 연구에서는 기존 보강법의 단점을 보강하여 복합재료 (Fiber reinforced polymer)와 Aluminum 체결부 이용한 FRP 내진보강재를 개발하였다. 비선형 유한요소 해석프로그램을 통해 개발된 FRP 내진보강재의 최적 보강량을 결정하였다.