• Title/Summary/Keyword: Hand Device

Search Result 774, Processing Time 0.028 seconds

A Development of Image Transfer Remote Maintenance Monitoring System for Hand Held Device (휴대용 화상전송 원격정비 감시시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.276-284
    • /
    • 2009
  • In this paper, we develop the image transfer remote maintenance monitoring system for hand held device which can compensate defects of human mistake. The human mistakes always happen when the worker communicate information each other to check and maintenance the equipment of the power plant under bad circumstance such as small place and long distance in power plant. A worker couldn't converse with other when in noisy place like Power plant. So, we make some hand device for handy size and able to converse in noisy place. The developed system can have improvement of productivity through increasing plant operation time. And developed system is composed of advanced H/W(hard ware) system and S/W(soft ware)system. The H/W system consist of media server unit, communication equipment with hand held device, portable camera, mike and head set. The advanced s/w system consist of data base system, client pc(personal computer) real time monitoring system which has server GUI(graphic user interface) program, wireless monitoring program and wire ethernet communication program. The client GUI program is composed of total solution program as pc camera program, and phonetic conversation program etc.. We analyzed the required items and investigated applicable part in the image transfer remote maintenance monitoring system with hand held device. Also we investigated linkage of communication protocol for developed prototype, developed software tool of two-way communication and realtime recording skill of voice with image. We confirmed the efficiency by the field test in preventive maintenance of plant power.

A Measurement System for 3D Hand-Drawn Gesture with a PHANToMTM Device

  • Ko, Seong-Young;Bang, Won-Chul;Kim, Sang-Youn
    • Journal of Information Processing Systems
    • /
    • v.6 no.3
    • /
    • pp.347-358
    • /
    • 2010
  • This paper presents a measurement system for 3D hand-drawn gesture motion. Many pen-type input devices with Inertial Measurement Units (IMU) have been developed to estimate 3D hand-drawn gesture using the measured acceleration and/or the angular velocity of the device. The crucial procedure in developing these devices is to measure and to analyze their motion or trajectory. In order to verify the trajectory estimated by an IMU-based input device, it is necessary to compare the estimated trajectory to the real trajectory. For measuring the real trajectory of the pen-type device, a PHANToMTM haptic device is utilized because it allows us to measure the 3D motion of the object in real-time. Even though the PHANToMTM measures the position of the hand gesture well, poor initialization may produce a large amount of error. Therefore, this paper proposes a calibration method which can minimize measurement errors.

Jain's hand retractor system and stand: an innovative device for hand surgery

  • Jain, Aakansh
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.389-391
    • /
    • 2021
  • Solo hand surgery is becoming increasingly common, mostly due to a lack of assistants and dedicated operating theatres. The solo hand surgeon faces challenges of proper hand positioning, elevation, and skin flap/tissue retraction. Most commercially available hand retractors or stands do not address all the relevant problems and are not economically feasible for trainee surgeons. The Jain's hand retractor system and stand, described herein, provides solutions to all these problems, and its simple design helps surgeons to reproduce it easily.

A Study of The Wearable Input Device Based on Human Hand-Motions Recognition

  • Daehui Won;Lee, Hogil;Kim, Jinyoung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.51.5-51
    • /
    • 2002
  • In this paper, we propose and developed a keyglove using the touch-typing method as new solutions to the problem of text input into the mobile computing devices. This device recognizes that character is typed in though the hand's movements analysis and requires no additional space on a person's desktop or work surface, and can be easily used with computers of any size, even the smallest mobile computer, and is designed as an input device for wearable computers and virtual environment. The concept of the wearable input device based on human hand-molies recognition.

  • PDF

The input device system with hand motion using hand tracking technique of CamShift algorithm (CamShift 알고리즘의 Hand Tracking 기법을 응용한 Hand Motion 입력 장치 시스템)

  • Jeon, Yu-Na;Kim, Soo-Ji;Lee, Chang-Hoon;Kim, Hyeong-Ryul;Lee, Sung-Koo
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.157-164
    • /
    • 2015
  • The existing input device is limited to keyboard and mouse. However, recently new type of input device has been developed in response to requests from users. To reflect this trend we propose the new type of input device that gives instruction as analyzing the hand motion of image without special device. After binarizing the skin color area using Cam-Shift method and tracking, it recognizes the hand motion by inputting the finger areas and the angles from the palm center point, which are separated through labeling, into four cardinal directions and counting them. In cases when specific background was not set and without gloves, the recognition rate remained approximately at 75 percent. However, when specific background was set and the person wore red gloves, the recognition rate increased to 90.2 percent due to reduction in noise.

Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study (기구조작후 치근표면의 조도에 관한 연구; 주사전자현미경적 in vivo 및 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.809-822
    • /
    • 1998
  • Adequate root preparation in the treatment of periodontal disease often involves mechanical instrumentation to remove plaque, calculus perhaps contaminated cementum. Although meticulous scaling and root planing may remove some cementum, the use of aggressive root planing to remove cementum does not appear warranted. So ultrasonic device and rotary instrument appear to be replacing hand instrument. But it is not clear those instruments make smooth root surface as hand instrument. The roghness of the root surface were evaluate with SEM following instrumentation with Gracey curette, Perio Clean and piezo ultrasonic device(Setlec) with various tip. 20 extracted teeth were used in vitro experiment, and 9 teeth of a patient destined for extraction for periodontal reasons were utilized in vivo experiment. It was demonstrated that hand curette created the smoothest surface, while diamond tip tended to roughen the root surface. But the hand curette, Perio Clean, and piezo ultasonic device with scaler tip tend to remove cementum completely. Piezo ultrasonic device with curette-like tip made the desirable smooth surface with partial removal of cementum.

  • PDF

Outcome of Rehabilitation Device Driven by Magnetic Force in Stroke Patients (뇌졸중 환자에서 자기력에 의해 유도되는 재활운동기기)

  • Park, Ji-Woo;Kim, Min-Su
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.101-109
    • /
    • 2020
  • PURPOSE: This study investigates the therapeutic effect of a prototype of a hand rehabilitation device based on magnetic forces. METHODS: Using an electromagnet and permanent magnets, we developed an end effector type device that induces various movements of the finger in accordance with the magnetic field direction. A total of 26 subacute stroke patients were enrolled and assigned to two groups in this randomized controlled trial. The intervention group received 30 minutes hand rehabilitation therapy per day for 4 weeks, using the device developed by us. Conventional physical therapies were conducted equally twice a day, 30 minutes per session, during the same period in both groups. RESULTS: After 4 weeks, rate of the Wolf Motor Function Test as a primary outcome measure showed significant improvement in the intervention group as compared to control group(p = .036). Scores of the Manual Function Test and Fugl-Meyer Assessment of upper limb were also significantly increased in the intervention group as compared to control group(p = .038 and p = .042, respectively). Moreover, the Korean version of Modified Barthel Index tended to improve after subjecting to physical therapy in both groups. CONCLUSION: Our results indicate that the novel hand rehabilitation device developed using a magnetic force, improves the hand motor functions and activities of daily life in subacute stroke patients.

A Hand Gesture Recognition Method using Inertial Sensor for Rapid Operation on Embedded Device

  • Lee, Sangyub;Lee, Jaekyu;Cho, Hyeonjoong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.757-770
    • /
    • 2020
  • We propose a hand gesture recognition method that is compatible with a head-up display (HUD) including small processing resource. For fast link adaptation with HUD, it is necessary to rapidly process gesture recognition and send the minimum amount of driver hand gesture data from the wearable device. Therefore, we use a method that recognizes each hand gesture with an inertial measurement unit (IMU) sensor based on revised correlation matching. The method of gesture recognition is executed by calculating the correlation between every axis of the acquired data set. By classifying pre-defined gesture values and actions, the proposed method enables rapid recognition. Furthermore, we evaluate the performance of the algorithm, which can be implanted within wearable bands, requiring a minimal process load. The experimental results evaluated the feasibility and effectiveness of our decomposed correlation matching method. Furthermore, we tested the proposed algorithm to confirm the effectiveness of the system using pre-defined gestures of specific motions with a wearable platform device. The experimental results validated the feasibility and effectiveness of the proposed hand gesture recognition system. Despite being based on a very simple concept, the proposed algorithm showed good performance in recognition accuracy.

A Framework for Designing Closed-loop Hand Gesture Interface Incorporating Compatibility between Human and Monocular Device

  • Lee, Hyun-Soo;Kim, Sang-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.533-540
    • /
    • 2012
  • Objective: This paper targets a framework of a hand gesture based interface design. Background: While a modeling of contact-based interfaces has focused on users' ergonomic interface designs and real-time technologies, an implementation of a contactless interface needs error-free classifications as an essential prior condition. These trends made many research studies concentrate on the designs of feature vectors, learning models and their tests. Even though there have been remarkable advances in this field, the ignorance of ergonomics and users' cognitions result in several problems including a user's uneasy behaviors. Method: In order to incorporate compatibilities considering users' comfortable behaviors and device's classification abilities simultaneously, classification-oriented gestures are extracted using the suggested human-hand model and closed-loop classification procedures. Out of the extracted gestures, the compatibility-oriented gestures are acquired though human's ergonomic and cognitive experiments. Then, the obtained hand gestures are converted into a series of hand behaviors - Handycon - which is mapped into several functions in a mobile device. Results: This Handycon model guarantees users' easy behavior and helps fast understandings as well as the high classification rate. Conclusion and Application: The suggested framework contributes to develop a hand gesture-based contactless interface model considering compatibilities between human and device. The suggested procedures can be applied effectively into other contactless interface designs.

The Effect of Visual Feedback on One-hand Gesture Performance in Vision-based Gesture Recognition System

  • Kim, Jun-Ho;Lim, Ji-Hyoun;Moon, Sung-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.551-556
    • /
    • 2012
  • Objective: This study presents the effect of visual feedback on one-hand gesture performance in vision-based gesture recognition system when people use gestures to control a screen device remotely. Backgroud: gesture interaction receives growing attention because it uses advanced sensor technology and it allows users natural interaction using their own body motion. In generating motion, visual feedback has been to considered critical factor affect speed and accuracy. Method: three types of visual feedback(arrow, star, and animation) were selected and 20 gestures were listed. 12 participants perform each 20 gestures while given 3 types of visual feedback in turn. Results: People made longer hand trace and take longer time to make a gesture when they were given arrow shape feedback than star-shape feedback. The animation type feedback was most preferred. Conclusion: The type of visual feedback showed statistically significant effect on the length of hand trace, elapsed time, and speed of motion in performing a gesture. Application: This study could be applied to any device that needs visual feedback for device control. A big feedback generate shorter length of motion trace, less time, faster than smaller one when people performs gestures to control a device. So the big size of visual feedback would be recommended for a situation requiring fast actions. On the other hand, the smaller visual feedback would be recommended for a situation requiring elaborated actions.