• Title/Summary/Keyword: Hydrogen House

Search Result 68, Processing Time 0.021 seconds

A Study on the Infrastructure of All-electric Houses in the Viewpoint of Hydrogen Economy (수소경제 관점의 전기에너지주택 보급기반 구축에 관한 연구)

  • Hwang, Sung-Wook;Lee, Hyeon-Ju;Kim, Kang-Sik;Nah, Hwan-Seon;Kim, Jung-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.1
    • /
    • pp.100-109
    • /
    • 2012
  • In this paper, some ideas are proposed to establish the infrastructure of all-electric houses which are able to reduce primary energy consumption and $CO_2$ emission by adopting heat pump systems and induction heating cookers excluding the use of fossil fuel energy. This electrification concept is based on the consumption of only one type of energy which means electricity as secondary energy and the conventional fossil fuel energy is just consumed to generate electricity as primary energy. All-electric house is laid on the extension of the hydrogen economy in a long-term viewpoint so that the effectiveness of this new conceptual house is estimated analyzing the reduction of $CO_2$ emission. In this analysis, the balance of electricity supply and demand is considered including the construction of new power plants by renewable energy such as nuclear, IGCC and fuel cell because decarbonization is an essential element of hydrogen technology and economy and this action is accomplished in both supply and demand side of electricity. The results are able to contribute to develop various useful hydrogen policies and strategies and some detail researches are required previously to make the best application of this new conceptual house.

Fabrication and Stability of Pd Coated Ta/YSZ Cermet Membrane for Hydrogen Separation (Pd 코팅된 Ta/YSZ 수소분리막의 제조 및 안정성)

  • Lee, Sang-Jin;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2010
  • Cermet membrane was fabricated with tantalum as hydrogen-permeable metal and $Y_2O_3$-stabilized $ZrO_2$ (YSZ) as ceramic supporter. Ta/YSZ cermet membrane was prepared through pre-sintering in He atmosphere and then main sintering under high vacuum and the impurities to originate from sintering and brazing could be removed by mechanical polishing. As-prepared membrane showed dense structure with continuous channel of tantalum. Hydrogen permeation experiment was conducted in the region of $200{\sim}350^{\circ}C$ using Ta/YSZ membrane coated with Pd for hydrogen dissociation. The crack in membrane was formed at $300^{\circ}C$ and the Pd coating layer has flaked off in spots. XRD results showed that tantalum reacted with hydrogen to form $Ta_2H$. The lattice expansion by $Ta_2H$ caused deterioration for membrane.

Fabrication and Stability of V/YSZ Cermet Membrane for Hydrogen Separation (수소 분리를 위한 V/YSZ cermet 분리막의 제조 및 안정성)

  • Jeon, Sung-Il;Park, Jung-Hoon;Lee, Sang-Jin;Choi, Soo-Hyun
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.62-68
    • /
    • 2010
  • The powder mixture for fabricating the cermet membranes was prepared by mechanically mixing 60 vol.% vanadium with $Y_2O_3$-stabilized $ZrO_2$ (YSZ). The powder mixture was pressed into disks, which were then sintered in vacuum at $1600^{\circ}C$ for 2 h. As-sintered membrane was dense and mounted to a stainless steel ring with brazing filler. Hydrogen fluxes of V/YSZ membrane have been measured in the range of $200{\sim}350^{\circ}C$ with 100% $H_2$. The crack was formed in the both sides of membrane at $350^{\circ}C$ and pressure of 0.5 bar. During permeation experiment, vanadium of V/YSZ membrane reacted with hydrogen to form $V_2H$ which was the origin of crack formation.

Fabrication and Hydrogen Permeation Properties of $V_{99.8}B_{0.2}$ Alloy Membrane for Hydrogen Separation (수소 분리를 위한 $V_{99.8}B_{0.2}$ 분리막의 제조와 수소투과특성)

  • Jung, Yeong-Min;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.21 no.4
    • /
    • pp.345-350
    • /
    • 2011
  • No investigation has yet been accomplished to screen the boron-doped effects on vanadium based metal membranes. The synthesis, hydrogen permeation properties and chemical stability of a novel Pd-coated $V_{99.8}B_{0.2}$ alloy membrane are presented in this report. Hydrogen permeation experiments have been performed to investigate the hydrogen transport properties through the Pd-coated $V_{99.8}B_{0.2}$ alloy membrane in the absolute pressure range 1.0~3.0 bar under pure hydrogen, hydrogen-carbon dioxide gas mixture at $400^{\circ}C$. The maximum hydrogen permeation flux was $48.5mL/min/cm^2$ for a 0.5 mm thick membrane under pure hydrogen. This results offer new direction in the synthesis of novel non-Palladium-based metal membranes for hydrogen separation in water-gas shift reaction.

Hydrogen separation of $V_{99.8}B_{0.2}$ Alloy Membrane in Water-gas shift Reaction (수성 가스 전이반응에서 $V_{99.8}B_{0.2}$ 합금 분리막의 수소분리)

  • Jeon, Sung-Il;Jung, Yeong-Min;Park, Jung-Hoon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • The influence of co-existing gases on the hydrogen permeation without sweep gas was studied through a Pd-coated $V_{99.8}B_{0.2}$ alloy membrane. Membranes have been investigated in the pressure range 1.5-8.0 bar under pure hydrogen, hydrogen-carbon dioxide and hydrogen-carbon monoxide gas mixture without sweep gas at $400^{\circ}C$. Preliminary hydrogen permeation experiments without sweep gas have been confirmed that hydrogen flux was $40.7mL/min/cm^2$ for a Pd-coated $V_{99.8}B_{0.2}$ alloy membrane (thick : 0.5 mm) using pure hydrogen as the feed gas. In addition, hydrogen flux was $21.4mL/min/cm^2$ for $V_{99.8}B_{0.2}$ alloy membrane using $H_2/CO_2$ as the feed gas. The hydrogen permeation flux decreased with decrease of hydrogen partial pressure irrespective of pressure when $H_2/CO_2$and $H_2/CO$mixture applied as feed gas respectively and permeation fluxes were satisfied with Sievert's law in different feed conditions. It was found from XRD, SEM/EDX results after permeation test that the Pd-coated $V_{99.8}B_{0.2}$ alloy membrane had good stability and durability for various mixtures feeding condition.

Correlation of Air Pollutants and Thermal Environment Factors in a Confined Pig House in Winter

  • Choi, Hong L.;Kim, Ki Y.;Kim, Hyunook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.4
    • /
    • pp.574-579
    • /
    • 2005
  • Optimal management of indoor air quality in a confined pig house, especially in winter, is indispensable for preventing infectious respiratory disease to workers and animals. This study was performed to elucidate the correlation of aerial contaminants and climate factors in a confinement. It was observed that indoor air contaminants ion in the confinement was the highest at 2:00-5:00 pm in a day, followed by 8:00-11:00 pm and 8:00-11:00 am. This was attributed to the increase of pig activities in the afternoon. The concentration of total dust and total airborne bacteria was found to have a significant correlation with temperature and relative humidity (p<0.05). Correlation of total dust and total airborne bacteria, total dust and ammonia, and total dust and odor were shown statistically significant at 95% confidence level. In conclusion, temperature and total dust concentration correlated significantly with all the parameters except for hydrogen sulfide ($H_2S$). This could be explained by the fact the dryness of pig feces by increase of interior temperature and resuspension of feed deposited on the floor by the pig activity, resulted in high generation of dust which adsorbed and carried the airborne bacteria and odor compounds in a confined pig house. It was proved that the adsorptive capacity of dust with ammonia ($NH_3$) was higher than that with hydrogen sulfide ($H_2S$).

The Characteristics of Hydrogen Permeation through Pd-coated $Nb_{56}Ti_{23}Ni_{21}$ Alloy Membranes (Pd 코팅된 $Nb_{56}Ti_{23}Ni_{21}$ 합금 분리막의 수소투과 특성)

  • Jung, Yeong-Min;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • We make a studyof the hydrogen permeability and chemical stability of $Nb_{56}Ti_{23}Ni_{21}$ metal alloy membrane. For this purpose, we produced the $Nb_{56}Ti_{23}Ni_{21}$ membrane which has 10 mm diameter and 0.5 mm thick, and experiment the hydrogen transport properties under two kinds of feed gas ($H_2$ 100%; $H_2$ 60% + $CO_2$ 40%) at $450^{\circ}C$C with variation of absolute pressure.The maximum hydrogen permeation flux was $5.58mL/min/cm^2$ in the absolute pressure 3 bar under pure hydrogen. And each case of feed gases about gas composition, the permeation fluxes were satisfied with Sievert's law, and the hydrogen permeation flux decreased with decrease of hydrogen partial pressure irrespective of temperature and pressure. After permeation test, we experiment the stability and durability of $Nb_{56}Ti_{23}Ni_{21}$ alloy membrane for carbon dioxide by XRD analysis.

Extraction of Athabasca Oil Sand with Sub- and Supercritical Water (아임계 및 초임계수를 이용한 Athabasca 오일샌드의 추출)

  • Park, Jung Hoon;Son, Sou Hwan;Baek, Il Hyun;Nam, Sung Chan
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.281-286
    • /
    • 2009
  • Bitumen extraction and sulfur removal from Athabasca oil sand were conducted using water in sub- and supercritical condition. Bitumen yield in micro reactor was investigated in the pressure range of 15~30 MPa, the temperature of 360 and $380^{\circ}C$ and water density $0.074{\sim}0.61g/cm^3$ for 0~120 min. Bitumen yield increased with reaction pressure irrespective of temperature and dramatically increased in especially supercritical region due to hydrogen formed from water gas shift reaction. Total amount of gas product decreased with reaction pressure but the portion of sulfur and hydrogen increased a little with increasing pressure to 25 and 30 MPa. It is seen that supercritical condition was favourable to the hydrogen formation and sulfur removal. Bitumen yield and sulfur removal from original oil sand reached a maximum 22% and 40% respectively in supercritical condition(the reaction time of 60 min at $380^{\circ}C$ and 25 or 30 MPa).

Fabrication of Pd/YSZ Cermet Membrane for Hydrogen Separation (수소 분리를 위한 Pd/YSZ Cermet 분리막의 제조)

  • Jeon, Sung-Il;Park, Jung-Hoon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.148-154
    • /
    • 2011
  • Metal-ceramic composite membrane have been developed to separate hydrogen from mixed gases, particularly product streams generated during coal gasification and methane reforming. Cermet membrane was fabricated with palladium as hydrogen-permeable metal and $Y_2O_3$-stabilized $ZrO_2$ (YSZ) as ceramic supporter. As-prepared membrane showed dense structure with continuous channel of palladium. The hydrogen flux of Pd/YSZ membrane have been measured in the range of 0.5~2 atm with 100% hydrogen gas. The results indicate that the hydrogen flux was 0.333 mL/$min{\cdot}cm^2$ at $450^{\circ}C$ and 2 atm. The crack was formed in the surface and cross-section of membrane.

An Experimental Study on the Explosion Hazards in the Fuel Cell Room of Residential House (주택 내 수소연료전지 전용실의 폭발 위험성에 대한 실험적 연구)

  • Park, Byoungjik;Kim, Yangkyun;Hwang, Inju
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.71-79
    • /
    • 2021
  • In this study, a real-scale fuel-cell room of volume 1.36 m3 is constructed to confirm the explosion characteristics of hydrogen-air mixture gas in a hydrogen-powered house. A volume concentration of 40% is applied in the fuel-cell room as the worst-case scenario to examine the most severe accident possible, and two types of doors (made of plastic sheet and wood) are fabricated to observe their effects on the overpressure and impulse. The peak overpressure and impulse based on distance from the ignition source are experimentally observed and assessed. The maximum and minimum overpressures with a plastic-sheet door are about 20 and 6.7 kPa and those with a wooden door are about 46 and 13 kPa at distances of 1 and 5 m from the ignition source, respectively. The ranges of impulses for distances of 1-5 m from the ignition source are about 82-28 Pa·s with a plastic-sheet door and 101-28 Pa·s with a wooden door. The amount of damage to people, buildings, and property due to the peak overpressure and impulse is presented to determine the safe distance; accordingly, the safe distance to prevent harm to humans is about 5 m based on the 'injuries' class, but the structural damage was not serious.