• Title/Summary/Keyword: Korean type building

Search Result 2,376, Processing Time 0.036 seconds

A study of Library design through space program redefine -Gunpo city Library competition- (스페이스프로그램 재정의를 통한 도서관 계획연구 -군포시립도서관 현상설계-)

  • Yoon, Hwon;Lee, Ji-Eun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.8 no.2
    • /
    • pp.93-104
    • /
    • 2008
  • Purpose of this paper is to research about new building type of Korean library and suggest the design of Library which based on the building type changes. This research is based on the idea that change of building type could be derived from Architects' designs. So, we analyzed space programs of Gunpo Library competition, redefined the space programs and suggested the direction of building type changes with program changes through design processes. The conclusions of this research are follows; first, we suggested new zoning system in library building design that is consisted of three separate building based on each building's own functions. Second, new zoning and library design would be helpful to making plan about library building competition. The method that we tried at this projec is useful to other complex building designs which have necessities to redefine building type.

  • PDF

Case Study on Landscape Defect Type of Defect Lawsuit in Apartment Building (공동주택 하자소송에서의 조경하자유형 사례분석)

  • Park, Jun-Mo;Seo, Deok-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.263-264
    • /
    • 2016
  • Since 2000s in Korea, apartment building tended to become goods or assets rather than houses. Therefore, conflicts between supplier and consumer were aggravated, and the defect dispute has been increased rapidly. This dispute enlarges to defect lawsuit and it is social and economical matter. The landscape work in apartment building is main work for a resident that appearance and convenient facility which lawn, tree, fountain, chair, playground, and etc. A number of defects surround landscape work are important issue in defect lawsuit, but, a related research is a minority, and a regulation is incomplete. Therefore, this study is basic study for standard of landscape defect type. As case study on defect lawsuit, draw a landscape defect type in apartment building.

  • PDF

An Analysis of Heating and Cooling Energy and Effect on Outdoor Air Cooling according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 및 외기냉방 효과 분석)

  • Roh, Ji-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.31-38
    • /
    • 2014
  • This study makes three apartment building complex an object of analyzing representative building types and energy consumption rate of house holds, and effect of outdoor air cooling. Recently created apatrment complex is composed of very various types of building, plan, and orientation etc. But, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively. Because architects are hard to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject is grasped, apartment building types were examined and representative types were extracted. In this study, energy simulation was conducted, and the effect to outdoor air cooling was analyzed about representative types of the subject apartment complex. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Besides solar gain, household layout of building, orientation, and plan etc. effects compositively on energy consumption rate. 2) The effect of ourdoor air cooling in building of tower type can be improved by arranging households appropriately.

Analysis the case study of tower type apartment by opening types of building surface (탑상형 아파트의 외피개방유형에 따른 전기에너지 사용량 사례 분석)

  • Kim, Yu-Won;Lee, Hyun-Soo;Kim, Eun-Hye
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.111-115
    • /
    • 2011
  • The purpose of this study was the analysis of electric energy consumption with the case study of tower type apartment's opening of building surface. We analyze the relationship between tower type apartment's opening of building surface and using electric energy consumption. The results of this study are: 1) The highest energy consumption of electric energy was on August without any influence of opening types of building surface. 2) Also, the south-west sides consumption of August was 848 kWh on Type B(one side opening) and it was the highest usage. 3) A house if facing west used more electricity than facing east when its opening of building surface's datum level is facing south. However, the house of facing east used more power than west when its opening of building surface's datum level is facing north. 4) When opening of building surface is facing on north-west or north-east, the opening of building surface's side of west and east used more electric power than north-west or north-east sides.

  • PDF

A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire- (필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로-)

  • Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF

Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer (사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가)

  • Park, Su-Jin;Jung, Sun-Young;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

A Study on the Deterioration Patterns of Building Components in the Rental Apartment Housing (임대공동주택 구성재의 열화도 패턴에 관한 연구)

  • Lee Kang-Hee
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.65-72
    • /
    • 2006
  • Most of buildings have been deteriorated with time-elapse by reflection of the building location, material, environmental circumstances and so on. The performance would go down and be demolished if anything could not be done after constructed. The maintenance should be required to preserve a decent living condition or improve a inferior condition by various plans and practices. The maintenance plan needs various data such as a repair scope, a repair time, a forecasted cost, a plan of management and so forth. Among the above required data for planning the maintenance, the deterioration characteristics of the building components would be first analyzed. The deterioration pattern would be a key role to affect and make a maintenance plan. In this paper, it aimed at classifying the deterioration patterns of building components. A deterioration pattern would be analyzed between the cumulative repair cost and time-elapse and modeled with these relations. A deterioration patterns are classified into 4 types-a accelerated type, a straight type, a temporary type and a slowly type. As a result of this research, a accelerated type includes window, window frame, general paintings, general water proofing in building components. A straight type includes the lacquer paintings, furnishings in building components and water supply pipe, boiler, sanitaries in mechanical facilities and lighting in electric facilities. Based on these research results, further study should be conducted to include any other components and an estimating model.

Basic study for development of bottom-up infill module for high rise building (고층 건축물을 위한 bottom-up Infill module 개발 기초 연구)

  • Sung, Soojin;Lim, Chaeyeon;Na, Youngju;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.164-165
    • /
    • 2015
  • Modular construction technique is an adaptation of factory-based mass production concept in ordinary manufacturing industries to construction industry and it assumes that panels, units, etc. are fabricated in factories and assembled in construction sites. Given its structural limitations, modular construction technique is primarily used in low-story buildings whose maximum height is usually five stories, but researchers are actively studying possible adaptation of modular construction technique to high-rise building designs these days as in the case of infill-type modular construction design. Infill-type modular construction technique, most frequently used in high-rise building construction projects, completes frame construction first in reinforced concrete structures and fills unit modules in such structures. However, infill-type modular construction technique leads to longer construction schedule accompanying increase in construction cost, cost overrun due to additional of temporary work, and possible damage to units in the wake of facility construction. Accordingly, this study is performed as a basic study for the development of bottom-up infill-type modular construction technique intended to construct structural frames and fill in units sequentially in a bid to address such drawbacks of current infill-type modular construction technique.

  • PDF

A Study on the Spatial Configuration Characteristics of the Apartment Building Type based on the Space Syntax Analysis (공간구문론 분석에 의한 아파트 주동형식별 공간배치 특성에 관한 연구)

  • 박몽섭;박찬돈;하재명
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.185-194
    • /
    • 2004
  • This paper deals with the spatial configuration of the unit floor plan based on the apartment building type. It is generally agreed that various apartment building types were organized by diverse apartment unit floor plan. The reason behind this diversity, apartment unit plan are affected by the environmental condition and the diverse spatial composition of the unit floor plan. Apartment building types were classified by the similarity of the justified-graph type. This types classified into two category; One core type which were classified by the shape of the core, and multiple core type which were compounded by more than two core. These categories divided into 5 types, and 2 types. Each types were compared in view of the mean depth, relative asymmetry, integration value. Consequently, these types could be classified in the number of the unit floor plan. It is profitable to 3 unit types which was analyzed in view of an indicator of the spatial configuration. Therefore, 3 unit types is favorable to the composition of the apartment building types.

An Analysis of Heating and Cooling Energy Cost according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 비용 분석)

  • Roh, Ji-Woon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.96-105
    • /
    • 2013
  • This study aims to investigate the energy performance of apartment in respect of complex design, building type and generation house layout and finally to produce the guide line for energy saving design. To grasp the present condition and problem about this subject, apartment building types were examined and representative types were extracted. Considering azimuth angle, private area, and generation number, building type of the subject apartment was classified in detail, energy simulation was conducted, and the effect to energy cost was compared. In the research, using VE energy simulation program, the heating and cooling load were calculated and converted to energy cost. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Energy cost is compared according to several azimuth in plank '一' type apartment. As the results, calculated gas cost is the best in $49^{\circ}$, but total cost is in $-31^{\circ}$. 2) Apartment buildings of tower types are compared, it is resulted that 'Y' type (azimuth $-7^{\circ}$, $-20^{\circ}$) is the best in gas cost, but the total cost is worst because of high cooling load.