• Title/Summary/Keyword: MCA

Search Result 459, Processing Time 0.039 seconds

Elution profiles of metronidazole from calcium sulfate beads

  • Burasarin Ithisariyanont;Saranya Poapolathep;Amnart Poapolathep;Pareeya Udomkusonsri
    • Journal of Veterinary Science
    • /
    • v.24 no.6
    • /
    • pp.74.1-74.15
    • /
    • 2023
  • Background: Antibiotic beads are used to treat local bacterial infections by delivering high drug concentrations to infected tissue. Objectives: This study examined the elution characteristics of metronidazole from metronidazole-calcium sulfate (MCa) and metronidazole-calcium-potassium sulfate (MCaK) beads over 20 days and the antibacterial efficacy of the beads after storage. Methods: The MCa and MCaK beads were prepared by mixing 250 mg of metronidazole and 10 g of calcium sulfate hemihydrate with water and a 3% potassium sulfate solution, respectively. The beads were placed in phosphate-buffered saline for the elution study. The metronidazole eluents were determined using high-performance liquid chromatography. The microstructures were examined by scanning electron microscopy (SEM), and the antimicrobial activity was evaluated by a microbioassay. Results: For the 20-day study, the total amount of metronidazole released was greater in the MCa beads than in the MCaK beads by 6.61 ± 0.48 mg (89.11% ± 3.04%) and 4.65 ± 0.36 mg (73.11% ± 4.38%), respectively. The amounts of eluted drugs from the MCa and MCaK beads were higher than the minimum inhibitory concentration at 0.5 ㎍/mL against anaerobic bacteria at both 20 days and 14 days. SEM showed that calcium crystals on the outer surface had dissolved after elution, and thinner calcium crystals were prominent in the MCaK beads. The MCa and MCaK beads exhibited antibacterial activity after setting, followed by storage at room temperature or 4℃ for 21 days. Conclusions: The MCa beads could release more drug than the MCaK beads, but all eluted metronidazole amounts were effective in controlling bacterial infections. Both metronidazole beads could be stored at ambient temperature or in a refrigerator.

Deflection Analysis of MCA/Si diaphragm for MEMS (MEMS용 MCA/Si diaphragm 구조의 변위해석)

  • Kim, Jae-Min;Lee, Jong-Choon;Yoon, Suk-Jin;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.372-375
    • /
    • 2003
  • MCA deflection control is a important technology for the development of MEMS applications. In this study, deflection analysis at the MLA/Si diaphragm was investigated by Finite Element Method. Analysis of Si diaphragm combined with MCA has been implemented into the ANSYS (Solid5 and Solid45). On the basis of this structure, deflection versus MCA number of layers has been modelled and MCA/Si contact area characteristics with different diaphragm conditions were analyzed. Consequently, it is expected that fabrication technology of MCA/Si diaphragm could be usefully applied for the fabrication process of high-performance piezoelectric MEMS devices.

  • PDF

Small Animal PET Imaging with [$^{124}I$]FIAU for Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression in a Hepatoma Model (간암 동물 모델에서 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabinofuranosyl-5-[$^{124}I$iodo-uracil ($[^{124}I]FIAU$) 소동물 PET 영상 연구)

  • Chae, Min-Jeong;Lee, Tae-Sup;Kim, June-Youp;Woo, Gwang-Sun;Jumg, Wee-Sup;Chun, Kwon-Soo;Kim, Jae-Hong;Lee, Ji-Sup;Ryu, Jin-Sook;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Purpose: The HSV1-tk gene has been extensively studied as a type of reporter gene. In hepatocellular carcinoma (HCC), only a small proportion of patients are eligible for surgical resection and there is limitation in palliative options. Therefore, there is a need for the development of new treatment modalities and gene therapy is a leading candidate. In the present study, we investigated the usefulness of substrate, 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabino-furanosyi-5-[$^{124/125}I$]iodo- uracil ([$I^{124/125}I$]FIAU) as a non-invasive imaging agent for HSV1-tk gene therapy in hepatoma model using small animal PET. Material and Methods: With the Morris hepatoma MCA cell line and MCA-tk cell line which was transduced with the HSV1-tk gene, in vitro uptake and correlation study between [$^{125}I$]FIAU uptake according to increasing numeric count of percentage of MCA-tk cell were performed. The biodistribution data and small animal PET images with [$^{124}I$]FIAU were obtained with Balb/c-nude mice bearing both MCA and MCA-tk tumors. Results:, Specific accumulation of [[$^{125}I$]FIAU was observed in MCA-tk cells but uptake was low in MCA cells. Uptake in MCA-tk cells was 15 times higher than that of MCA cells at 480 min. [$^{125}I$]FIAU uptake was linearly correlated (R2 =0.964, p =0.01) with increasing percentage of MCA-tk numeric cell count. Biodistribution results showed that [$^{125}I$]FIAU was mainly excreted via the renal system in the early phase. Ratios of MCA-tk tumor to blood acting were 10, 41, and 641 at 1 h, 4 h, and 24 h post-injection, respectively. The maximum ratio of MCA-tk to MCA tumor was 192.7 at 24 h. Ratios of MCA-tk tumor to liver were 13.8, 66.8, and 588.3 at 1 h, 4 h, and 24 h, respectively. On small animal PET, [$^{124}I$]FIAU accumulated in substantial higher levels in MCA-tk tumor and liver than MCA tumor. Conclusion: FIAU shows selective accumulation to HSV1-tk expressing hepatoma cell tumors with minimal uptake in normal liver. Therefore, radiolabelled FIAU is expected to be a useful substrate for non-invasive imaging of HSV1-tk gene therapy and therapeutic response monitoring of HCC.

Fabrication of MCA Valve For MEMS (MEMS용 적층형 압전밸브의 제작)

  • Kim, Jae-Min;Yun, Jae-Young;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.129-132
    • /
    • 2004
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 sccm at a supplied voltage of 100 V with a 50 % duty cycle, maximum non-linearity was 2.24 % FS and leak rate was $3.03{\times}10^{-8}\;pa{\cdot}m^3/cm^2$. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and air transportation industry.

  • PDF

Design, Fabrication and Characteristics of a MCA Valve (적층형 압전밸브의 설계, 제작 및 특성)

  • Chung, Gwiy-Sang;Kim, Jae-Min;Yoon, Suk-Jin;Jeong, Soon-Jong;Song, Jae-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.230-235
    • /
    • 2004
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 seem at a supplied voltage of 100 V with a 50% duty cycle, maximum non-linearity was 2.24% FS and leak rate was $3.03{\times}10^{-8}pa{\codt}m^{3}/cm^{2}$. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and air transportation industry.

Endovascular Approach in Patients with Acute Complete Occlusion Due to Middle Cerebral Artery Dissection

  • Park, Kang-Hoon;Kwak, Hyo Sung;Park, Jung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.717-722
    • /
    • 2020
  • Objective : Dissection of the middle cerebral artery (MCA) is less common than dissection of vessels in the vertebrobasilar system or carotid artery. Acute complete occlusion related to MCA dissection is extremely rare. We report an endovascular approach in patients with acute complete occlusion due to MCA dissection. Methods : We reviewed retrospectively the endovascular procedure and clinical results for acute-stroke patients who underwent recanalization from October 2014 through December 2018. Initial imaging findings and the endovascular procedure were analyzed for patients with acute complete occlusion due to MCA dissection. Results : We undertook first-line aspiration thrombectomy using a Penumbra catheter in 294 patients with acute occlusion of the M1 segment. Of these patients, seven were confirmed to have acute complete occlusion due to MCA dissection. All patients had angiographic findings of an intimal flap at the proximal occlusion site of the MCA. One patient complained of severe headache during microcatheter passage through the occluded lesion and died due to massive bleeding caused by rupture of the false lumen. The remaining patients underwent initial contact aspiration thrombectomy without microcatheter passage. After aspiration thrombectomy, six patients had delayed flow through the MCA. One patient underwent stenting of the MCA because of progressive symptoms. Conclusion : An intimal flap at the proximal portion of an occluded MCA can suggest the possibility of MCA dissection. Contrast aspiration thrombectomy without microcatheter passage can reduce the risk of false lumen rupture in cases of MCA dissection.

Electric-Field-Induced Strain Properties of Multi Layer Ceramic Actuator Using PMN-PZ-PT Ceramics (PMN-PZ-PT 세라믹스를 이용한 적층형 액츄에이터의 변위특성)

  • Ha, Mun-Su;Jeong, Soon-Jong;Koh, Jung-Hyuk;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.620-623
    • /
    • 2003
  • Non-linear behaviors of multilayer piezoelectric ceramic actuator (MCA) were investigated under electrical and mechanical stress. DC 100 V bias was applied to the MCA to obtain displacement. Laser vibrometer, which using Doppler effect, was employed to characterize displacement caused by $d_{33}$ mode of MCA. To understand this non-linear behavior of MCA, displacement was measured and compared under different load states. By increasing load, electric field-induced strain and piezoelectric constant($d_{33}$) of MCA was decreased. We attribute this phenomenon to the domain wall motion and depoling of MCA under heavy load.

  • PDF

Comparison of Cerebral Blood Flow between Patients with Metabolic Syndrome and Normal Group to Evaluate Diagnostic Value of Transcranial Doppler Ultrasound (대사증후군 환자군과 정상군의 뇌혈류 측정 비교를 통한 뇌졸중 위험인자에 대한 TCD의 진단적 가치 고찰)

  • Um, Eun-Jin;Park, Woo-Rham;Kim, Ju-Sung;Lee, Beom-Joon;Na, Byung-Jo
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.85-100
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate diagnostic value of Transcranial Doppler Ultrasound about risk factor of stroke by comparing blood flow between patients with metabolic syndrome(MS group) and Normal group. Methods: 62 metabolic syndrome patients and 106 healthy adults were selected who had no cerebrovascular diseases, cardiovascular diseases and other systemic diseases. We measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of MCA, ACA, PCA, VA, ICA in two groups using TCD. All subjects were divided by gender and age. Results: In comparing Ms group with normal group, Vm in the MCA, ACA, PCA, ICA and Vs in the MCA, ICA were lower in MS group. In all vessels, PI of MS group were higher than that of Normal group. In all vessels, Vm and Vs revealed negative correlation with age and PI revealed positive correlation with age. In 20-39 year olds, there was decrease in the Vs and Vm and increase of PI of MS group in comparison with normal group. There was significant difference in the Vm of PCA, ICA, Vs of MCA, PCA, ICA and PI of MCA, ACA. In 40-59 year olds, Vm in the MCA, ACA, ICA and Vs in the MCA, ACA were lower in MS group. PI in the MCA, ACA, PCA, ICA were higher in MS group. In 60-79 year olds, Vm of MCA, PCA, ICA was decreased in MS group than Normal group with no statistical signification. Vs in the MCA was lower and PI in the PCA was higher in MS group. In male, Vm of PCA and Vs of MCA were lower and PI of MCA, ACA, PCA, ICA were higher in MS group. In female, Vm of MCA, PCA, ICA and Vs of MCA, ICA were lower and PI of ACA, PCA, VA, ICA were higher in MS group. Conclusions: The significant difference in Vm, Vs, PI between MS group and normal group suggests hemodynamic disorder. Screening and prognosing high risk group can be done through TCD and this can be used to prevent stroke. More detailed study will be needed.

Saccular Aneurysm at the Anterior Communicating Artery Complex Associated with an Accessory Middle Cerebral Artery : Report of Two Cases and Review of the Literature

  • Kang, Dong-Hun;Park, Jae-Chan;Park, Seong-Hyun;Hamm, In-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.568-571
    • /
    • 2009
  • Accessory middle cerebral artery (MCA) is an infrequent vascular anomaly of the brain. Cerebral aneurysms associated with this anomalous artery are also very rare. To our knowledge, there have only been ten previous reports of an aneurysm associated with accessory MCA. The authors present two patients with accessory MCA-related aneurysms. A 38-year-old male and a 59-year-old female both presented with sudden-onset severe headache. In both patients, computed tomography (CT) scan revealed subarachnoid hemorrhage. A subsequent angiogram demonstrated an accessory MCA arising from the anterior cerebral artery (ACA) and a saccular aneurysm at the anterior communicating artery (ACoA) complex associated with an accessory MCA. Surgical clipping allowed for complete exclusion of the aneurysm from the arterial circulation. Based on our review of the ten cases of aneurysms associated with accessory MCA documented in the literature, we suggest that accessory MCA-related aneurysms can be classified according to whether the accessory MCA originates from the proximal A1 segment or from the ACoA complex. We also emphasize the importance of precise interpretation of preoperative angiograms and intraoperative precaution in determining the presence of this anomalous artery prior to temporary clip placement.

Effect of Sophora Subprostrata Fractions on Focal Ischemic Brain Damage Induced by Middle Cerebral Artery Occlusion in Rats(II) (광두근 분획물이 중대뇌동맥폐쇄에 의한 뇌허혈손상에 미치는 효과(II) -조직화학적 평가를 기준으로-)

  • Choi Moon-Seok;Kim Youn-Sub
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.4
    • /
    • pp.993-999
    • /
    • 2005
  • This research was peformed to investigate protective effect of Sophora Subprostrata fractions against focal ischemic brain damage after middle cerebral artery(MCA) occlusion using intraluminal suture. Rats were divided into six groups: MCA-occluded group(Control): each administered groups with Sophora Subprostrata total phase(Total), Sophora Subprostrata Aqueous phase (Aqueous), Sophora Subprostrata BuOH phase(BuOH), and Sophora Subprostrata Alkaloid phase(Alkaloid) after MCA-occlusion; sham-operated group(Sham). The right MCA was occluded by A poly-L-lysine coated 4-0 nylon suture thread through the internal carotid artery permanently. Sophora Subprostrata and fractions were administered orally(Smg/ml) for 7 days after MCA-occlusion. The Drain tissue was stained with $2\%$ triphenyl tetrazolium chloride on ischemic brain tissue(2mm section). The results showed that 1) Sophora Subprostrata total phase reduced infarct size and total infarct volume compared to the control group at 24 hours after MCA-occlusion, 2) Sophora Subprostrata Aqueous phase reduced infarct size and total infarct volume compared to the control group at 24 hours after MCA-occlusion, 3) Sophora Subprostrata Alkaloid phase reduced infarct size compared to the control group at 24 hours after MCA-occlusion, but 4) at 7 days after MCA-occlusion, Sophora Subprostrata did not show effective recovery compared with control group. Sophora Subprostrata has protective effects against brain damage at the early stage of focal cerebral ischemia. Sophora Subprostrata total and Aqueous phase produced more pronounced protective effect against focal ischemic brain damage.