• Title/Summary/Keyword: MLA

Search Result 93, Processing Time 0.026 seconds

Immunostimulating Lectins from Marine Natural Products: Characteristics of the MLA-I, MLA-II and MLA-III (해양 천연물로부터 면역기능 조정제 렉틴 개발 : MLA-I, MLA-II, MLA-III의 특성)

  • 정시련;김장환;전경희
    • YAKHAK HOEJI
    • /
    • v.39 no.3
    • /
    • pp.243-251
    • /
    • 1995
  • Three new lectins, MLA-I, MLA-II and MLA-III, have been isolatedand purified from the hemolymph of Meretrix lusoria and reported previously. Biophysicochemical characteristics were investigated with these three MLA lectins. The MLA lectins agglutinated human erythrocytes non specifically and proved as D-galactose group carbohydrate specific. Molecular weight of ML.A-I. II and III were estimated to be 330, 500 and 310KD, respectively, by gel filtration on Sepharose CL-6B column. On SDS-polyacrylamide gel electrophoresis, ML.A-I was dissociated into a single subunit of 42KD, MLA-II was into the twelve subunits of 46, 32, 30, 28, 25, 23. 22, 20. 19, 16, 15, and 14KD, and MLA-III was into the two subunits of 72 and 44KD. The pl of MLA-I, II, III were 4.0. 4.9 and 5.0. Amino acid analysis revealed a high contents of acidic and hydroxy amino acids, and a paucity of sulfur containing amino acids. Proline was not contained in MLA-II.

  • PDF

Purfication of New Lectins, MLA-II and MLA-III, form the Hemolymph of Meretrix lusoria (백합조개 체액으로부터 새로운 렉틴 MLA-II 및 MLA-III의 정제)

  • Kim, Jang-Hwan;Chung, See-Ryun;Jeune, Kyung-Hee
    • YAKHAK HOEJI
    • /
    • v.38 no.4
    • /
    • pp.394-400
    • /
    • 1994
  • As a previous step for the development of immunostimulating substance from marine natural products the two new lectins, MLA-II and MLA-III, have been isolated and purified from the hemolymph of Meretrix lusoria in addition to the previously reported MLA-I. The new lectins molecules were characterized as pure by electrophoretic studies.

  • PDF

Lymphocytes Mitogenic and Immunochemical Characteristics of the Immunomodulating Lectins, MLA, from Marine Natural Products (해양 천연물에서 분리한 면역기능 조정제 렉틴 MLA의 림프구 자극분열효과 및 면역화학적 특성)

  • 전경희;김장환;정시련
    • YAKHAK HOEJI
    • /
    • v.39 no.3
    • /
    • pp.252-259
    • /
    • 1995
  • Isolation, purification and characterization of biophysicochemical properties of the three new lectins, MLA-I, MLA-II, MLA-III from the hemolymph of Meretrix lusoria have been reported previously. A series of immunochemical studies were investigated in this work. The three lectins were revealed as having partial identity each other by immunodiffusim and immunoelectrophoresis. These results suggest that MLA lectins are isolectins having similar biophysicochemical properties. Particularly, MLA-I proved to be a potent mitogen for murine splenic as well as human peripheral lymphocytes, and the optimum mitogenic dose were 62.5 and 1.95 $\mu\textrm{g}$/ml, respectively.

  • PDF

Development of Microlens Array for Maskless Lithography Application (Maskless lithography 응용을 위한 마이크로렌즈 어레이 개발)

  • Nam, Min-Woo;Oh, Hae-Kwan;Kim, Geun-Young;Seo, Hyun-Woo;Wei, Chang-Hyun;Song, Yo-Tak;Yang, Sang-Sik;Lee, Kee-Keun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.4
    • /
    • pp.33-39
    • /
    • 2009
  • A microlens array (MLA) was developed based on the wet-etched quartz substrate and coating of UV adhesive on the substrate for maskless lithography application. The developed MLA has the focal length of ${\sim}45\;{\mu}m$ and the spot size of ${\sim}1\;{\mu}m$. The spot size of the focused beam passing through the MLA was detected by CCD camera, and its intensity was monitored by beam profiler. Uniform spots with nearly identical intensities were observed on the focal plane when a beam passes through the fabricated MLA. The focal length was varied depending on thickness of the coated UV adhesive. The thicker the thickness of the UV adhesive was, the shorter the focal length of the MLA was. With a general mask aligner, UV beam focusing was tested onto photoresist (PR). The beams were well focused onto PR when UV passes through the MLA. Depending on the variable distances from the MLA, beam sizes onto PR were controlled. Even at high temperature for a long time, the performances of the MLA were not changed.

  • PDF

Fabrication of Microlens Array Using Photoresist Thermal Reflow (Photoresist Thermal Reflow를 이용한 Microlens Array 제작)

  • Hwang, Sung-Ki;Baek, Sang-Hoon;Kwon, Jin-Hyuk;Park, Yi-Soon
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.2
    • /
    • pp.118-122
    • /
    • 2009
  • An optical sheet with microlens array (MLA) is designed and fabricated as a substitute for the prism sheets of LCD backlight. Using photoresist thermal reflow, MLAs were fabricated on PET film with thickness of $100{\mu}m$, and we measured the change of MLA profile in terms of exposure time, reflow temperature and reflow time.

Comparison of L5178Y tk+/- Mouse Lymphoma Assay and In vitro Chromosome Aberration Test

  • Lee, Michael;Jung Kwon;Cho, Ji-Hee;Hong, Mi-Young;Kim, Eun-Joo;Junghee Han;Chung, Moon-Koo;Han, Sang-Seop
    • Toxicological Research
    • /
    • v.18 no.2
    • /
    • pp.129-138
    • /
    • 2002
  • The mouse lymphoma assay (MLA) has been recently validated as a sensitive and specific test system to determine the genotoxic potential for a chemical. The objective of this study is to evaluate the utility of MLA for detecting mutagens. Especially, to compare MLA with the in vitro chromosomal aberration test (CA), we performed MLA using the microwell method with three chemicals (hydroxyurea, theophylline and amino acid copper complex), which were reportedly positive in the CA. In cell treated with hydroxyurea, anti-neoplastic agent that blocks DNA replication, evidence of a positive response was obtained without S9 mix for 4 h and 24 h. In addition, analysis of colony size distribution at concentration that gave an elevated mutant fraction showed that hydroxyurea induced a high proportion of small type colonies, indicating that hydroxyurea-induced mutation is associated with large chromosomal deletion. Conversely, negative MLA result was obtained for theophylline, which was wed as central nervous system stimulator. Although theophylline increased the mutant frequency at concentration of 1250 $\mu\textrm{g}$/$\textrm{m}{\ell}$ with S9 mix for 4 h, a concentration-related increase in mutant frequency was not observed. The MLA result of amino acid copper complex was considered equivocal because the positive result was obtained at concentration showing 10% or less RS or RTG. Thus, among 3 CA-positive chemicals, positive MLA result was obtained for one. The other two chemicals were negative and equivocal. However MLA, which evaluates mutagenic potential of chemicals through colony formation by cell grouth, may provide a higher predictivity of carcinogenesis than CA.

South Korean Elementary Students' Mathematical Listening Ability (초등학생의 수학 청해력 실태 조사 연구)

  • Kim, Rina
    • Communications of Mathematical Education
    • /
    • v.37 no.2
    • /
    • pp.183-197
    • /
    • 2023
  • Mathematical listening ability(MLA) refers to the capability to listen to speech languages that contain mathematical principles and concepts and understand their meanings, distinguishing it from daily life and listening in other subject classes. In this study, I investigated 834 elementary school students' MLA adapting a MLA survey items. Through the statistical analysis results of the survey, I confirmed that students' MLA had a significant correlation with gender, grade, and school location. Female students' MLA was statistically significantly higher than that of male students. MLA increased with grade and then decreased again in 6th grade. In addition, students' MLA was statistically significant differences according to the location of the school. The results of this study might be used as the basis for follow-up research and development of teaching and learning materials related to MLA.

Simulation Study on the Minimization of Moiré Patterns Caused by Microlens Array Films for Backlight Applications

  • Joo, Byung-Yun;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.538-545
    • /
    • 2014
  • Microlens array (MLA) films have been used as brightness-enhancement components in many illumination systems, such as a backlight, which should meet the industrial needs of low cost and high brightness performance. A hexagonally-arranged MLA (HA-MLA) was chosen due to its high filling factor, which was a prerequisite for achieving high brightness-enhancement capability. The moir$\acute{e}$ fringes produced in a film stack composed of two HA-MLA were investigated, under four different lens configurations, by optical simulation. It was found that randomizing the lens configuration, while keeping the filling factor high, was effective way to develop high-gain MLA films for backlight applications.

Comparison of the Foot Muscle EMG and Medial Longitudinal Arch Angle During Short Foot Exercises at Different Ankle Position

  • Yoon, Hyeo-bin;Kim, Ji-hyun;Park, Joo-hee;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.46-53
    • /
    • 2017
  • Background: The MLA is supported by both the abductor hallucis (ABH) and the extrinsic muscles. Insufficient muscular support may lower the MLA when the body's weight is applied to the foot. The short foot exercise (SFE) is effective in increasing the height of the MLA for people with flat feet. Most of the research related to the SFE has simply evaluated the efficiency of the exercise using enhanced ABH electromyography (EMG) activation. Since the tibialis anterior (TA), peroneus longus (PER), and ABH are all involved in supporting the MLA, a new experiment design examining the EMG of the selected muscles during SFE should be applied to clarify its effect. Objects: Therefore, this study aimed to clarify the effect of the SFE in different ankle position on the MLA angle and the activation of both the intrinsic and extrinsic muscles and to determine the optimal position. Methods: 20 healthy subjects and 12 subjects with flat feet were recruited from Yonsei University. The surface EMG and camera were used to collect muscle activation amplitude of TA, PER, and ABH and to capture the image of MLA angle during SFE. The subjects performed the SFE while sitting in three different ankle positions-neutral (N), dorsiflexion (DF) at 30 degrees, and plantar flexion (PF) at 30 degrees. Results: ABH EMG amplitudes were significantly greater in N and DF than in PF (p<.05). Muscle activation ratio of TA to ABH was the lowest in PF (p<.05). MLA angle in both groups significantly decreased in PF (p<.01). The TA and ABH was activated at the highest level in DF. However, in PF, subjects significantly activated the ABH and PER with relatively low activation of TA. Conclusion: Therefore, researchers need to discuss which SFE condition most effectively use the arch support muscle for flat foot.

Display 특성 향상을 위한 MLA 광소자 개발 연구

  • Jeong, Han-Uk;Kim, Gwang-Yeol;Lee, Gong-Su;Sin, Seong-Uk;Park, Hong-Jin;Choe, Byeong-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.199-199
    • /
    • 2009
  • Recently, polymeric microlens arrays have become important elements in many applications. Microlens arrays have been used to enhance luminance efficiency and luminance power efficiency of light-emitting diodes (LEDs) and organic LEDs. Many processes for fabrication of microlens array are studied. Though the MLA has been fabricated by electroformed mold, LIGA process and reflow method, these methods were required masks, multiple process steps and post processing. In this paper, we proposed rapid and direct UV laser direct fabrication process using colorless liquid photopolymer, NOA60 for polarization activated microlens. The microlens arrays are formed on the NOA60 on glass, after the focused laser energy was irradiated to the material. The diameter of MLA was varied from 42 to 88 ${\mu}m$, and the height from 0.9 to 1.6 ${\mu}m$. The MLA fabricated using NOA60 shows more then 85% transmittance as well as good hardness for optical module.

  • PDF