• Title/Summary/Keyword: Measurement Technique

Search Result 4,368, Processing Time 0.055 seconds

An experiment for comparison of an imaging measurement technique for a water spray with a phase-Doppler measurement technique (PDPA와 화상처리법(PMAS)의 비교를 위한 분무 측정 실험)

  • Jurng, J.;Lee, G.W.
    • Journal of ILASS-Korea
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • Two measurement techniques of droplet sizing, an imaging technique(PMAS) and a phase-Doppler measurement technique (PDPA), have been compared using a water spray from a pressurized-type swirl nozzle. The result showed that SMD measured by PDPA was larger than that measured by PMAS by about 40 %. Such discrepancy of SMD could be explained by the fact that the light signal intensity used by PDPA can be biased towards larger particles. On the other hand there could be lower opportunity to capture the images of the large particles with PMAS, since the large particles could be out of sight due to their high speed.

  • PDF

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

A Study on Measurement Uncertainty of CMM used for Inspection of Precision Machined parts. (정밀가공 부품 검사에 사용되는 삼차원측정기의 측정불확도 연구)

  • 이갑조;오상록;김종관
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.3-9
    • /
    • 2004
  • The machining parts must be produced within the specification of drawing and those will be able to meet function and efficiency. At that time. it is necessary not only precision machine or machining technique but also the measurement technique is very important. So. the improvement of precise measurement technique is to be joined together at once with improvement of product technique. Finally. he quality and value of the parts are decided by precision measurement. This paper aims to study on he measurement uncertainty when the machined parts are inspected with 3-dimensional coordinate measuring machine. The objectives are to remove an error of measurement and to improve quality and productivity of the mass products.

  • PDF

Precision Measurement Technique of DC Voltage/Resistance Ratio (직류 전압/저항 비율 초정밀 측정기술)

  • Kim, Kyu-Tae;Yu, Kwang-Min
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.3
    • /
    • pp.96-99
    • /
    • 2002
  • We developed 1:1 resistance ratio measurement system for precision measurement of a series-resistor type dc voltage divider. By using active guard technique and exchange technique, any leakage effects, which are one of the most critical error sources, were successfully removed. The best measurement uncertainty with the developed ratio measurement system was estimated to be approximately $10^{-8}\;for\;10\;k{\Omega}\;and\;100\;k{\Omega}$.

A Surface Generation Velocity Measurement Technique Using the Buried Channel MOS Structure (Buried Channel MOS 구조를 이용한 표면생성속도 측정 방법)

  • 조성호;허연철;이종덕
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.7
    • /
    • pp.56-63
    • /
    • 1992
  • A measurement technique of the surface generation velocity S$_o$ using the BC(buried channel) MOS structure with shallow and low doped channel layer (BC MOS S$_o$ measurement technique) is presented and verified analytically and experimentally. Using this measurement technique, S$_o$ can be measured more accurately than that measured using the gate-controlled diode SS1oT measurement technique. When S$_o$ is measured for the two techniques from a BC MOS structure test patten with gate length of 171$\mu$m, the results are 0,66cm/sec and 0.28cm/sec for the former and the latter respectively.

  • PDF

A Study on Measurement Uncertainty of 3-dimensional Coordinate Measuring Machine used for Inspection of Precision Machined parts (정밀가공 부품 검사에 사용되는 3차원측정기의 측정불확도 연구)

  • Lee Gab Jo;Oh Sang Lok;Kim Jong Kwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.55-61
    • /
    • 2005
  • The machining Parts must be Produced within the specification of drawing and those will be able to meet faction and efficiency. At that time, it is very important not only precision machine and machining technique but also the measurement technique. So, the improvement of measurement technique is to be joined together at once with improvement of machining technique. Finally, the quality and value of the parts are decided by precision measurement. This paper aims to study on the measurement uncertainty when the machined parts are inspected with 3-dimensional coordinate measuring machine. The objectives remove an error of measurement and remove a quality of mass products.

An integrated visual-inertial technique for structural displacement and velocity measurement

  • Chang, C.C.;Xiao, X.H.
    • Smart Structures and Systems
    • /
    • v.6 no.9
    • /
    • pp.1025-1039
    • /
    • 2010
  • Measuring displacement response for civil structures is very important for assessing their performance, safety and integrity. Recently, video-based techniques that utilize low-cost high-resolution digital cameras have been developed for such an application. These techniques however have relatively low sampling frequency and the results are usually contaminated with noises. In this study, an integrated visual-inertial measurement method that combines a monocular videogrammetric displacement measurement technique and a collocated accelerometer is proposed for displacement and velocity measurement of civil engineering structures. The monocular videogrammetric technique extracts three-dimensional translation and rotation of a planar target from an image sequence recorded by one camera. The obtained displacement is then fused with acceleration measured from a collocated accelerometer using a multi-rate Kalman filter with smoothing technique. This data fusion not only can improve the accuracy and the frequency bandwidth of displacement measurement but also provide estimate for velocity. The proposed measurement technique is illustrated by a shake table test and a pedestrian bridge test. Results show that the fusion of displacement and acceleration can mitigate their respective limitations and produce more accurate displacement and velocity responses with a broader frequency bandwidth.

Sub-sampling Technique to Improve the Measurement Speed of White Light Scanning Interferometry (백색광 주사 간섭계의 측정 속도 개선을 위한 서브 샘플링 기법 연구)

  • Chyun, In-Bum;Joo, Ki-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.999-1006
    • /
    • 2014
  • In this investigation, we explain the sub-sampling technique of white light scanning interferometry (WLSI) to improve the measurement speed. In addition to the previous work using Fourier domain analysis, several methods to extract the height from the correlogram of WLSI are described with the sub-sampling technique. Especially, Fourier-inverse Fourier transformation method adopting sub-sampling technique is proposed and the phase compensation technique is verified with simulation and experiments. The main advantage of sub-sampling is to speed up the measurements of WLSI but the precision such as repeatability is slightly poor. In case of measuring the sample which has high height step or difference, the proposed technique can be widely used to reduce the measurement time.

The measurement of partial discharge for preventive diagnosis in power machinery (전력용 기기의 예방진단을 위한 부분방전측정)

  • 김태성;구할본;임장섭;정우성
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.42-48
    • /
    • 1994
  • The preventive diagnosis technique for power system is being highlighted as a research area for deterioration of insulation in machinery because of high-voltage power system. We make efforts to develop not only diagnosis of aging state but also detection of defects in the initial stage from preventive diagnosis technique. Especially, partial discharge is actively studied as a non-destructive diagnosis technique and very useful because partial discharge measurement reduces damage than conventional diagnosis technique. The loaded stress during this test is smaller than that of other diagnosis techniques. But the continuous research for various complicated analysis method is required because partial discharge has very small signals and its signals have complex forms. In this paper, the measurement of partial discharge was investigated and studied on many specimens with void. We made samples having artificial voids and measured partial discharge. In order to use as a practical diagnosis technique, we studied ways of measurement, measured illustrations and types of partial discharge which could be used in order to diagnose defects of power machinery.

  • PDF

Measurement of optical flow using horn and anandan techniques (Horn과 Anandan기법을 이용한 Optical flow 측정)

  • 송석진;남기곤;이장명
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.685-688
    • /
    • 1998
  • Measurement of optical flow is a core problem of matching through the analysis of image sequences. In this paper, horn's and anandan's techniques are analyzed to derive a better technique for matching. Experimental results show that Horn's technique has low accuracy in measuring the velocity of optical flow while anandan's technique has poor performaance for diverging images. Based upon this observation, a new technique for the measurement of optical flow is proposed.

  • PDF