Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

Design of Automatic Fire Prevention and Suppression System for Photovoltaic Connection Module (태양광 접속반의 자동 화재 예방 및 진압 시스템 설계)

  • Lee, Kang Won;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2022
  • A solar power generation system uses a solar module that collects solar radiation energy, a connecting board that collects DC power generated from the solar module, and a diode to prevent reverse current from flowing from an inverter to the solar module. The existing photovoltaic connection module consists of only fuses and diodes for reverse polarity and overcurrent blocking, and does not have fire diagnosis, prevention, and suppression functions in the event of a fire. To solve this problem, this paper presents a method to monitor the internal state of the photovoltaic connection module using several sensors and to prevent and extinguish a fire using solenoid valves and fire extinguishing agents when a fire is detected. Through the experiment, it was confirmed that the proposed method normally suppresses the fire in event of a fire.

Reconfiguration of PV Module Considering the Shadow Influence of Photovoltaic System (태양광 발전시스템의 그림자 영향을 고려한 PV 모듈의 재구성)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.36-44
    • /
    • 2013
  • This paper proposes the reconfiguration of PV module considering shadow influence of photovoltaic system. The PV system is consisted series-parallel connection of PV module. The voltage and current between PV modules become unbalance when shadow occurs to PV module. If shadow occurs to the series connection PV module, the output current is limited to current of shaded PV module. Also if shadow occurs to the parallel connection PV module, the output voltage is limited to voltage of shaded PV module. These problems are caused power loss. Therefore, the PV module in this paper consist using the fixed module and variable module by shaded conditions. The reconfiguration of PV module can compensates the shadow influence by changing connection of a variable module when shadow is occurred to PV module. A validity of the reconfiguration of PV module proposed in this paper proves through comparing with performance of conventional PV module.

The developed connection method on Si PV module (결정질 태양전지 모듈의 개선된 Connection Method)

  • Ji, Yang-Geun;Kong, Ji-Hyun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Yeong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.115-120
    • /
    • 2009
  • In this paper, we measurement the resistance on the flat wire for PV module. There is some kind of flat wire that has different length and different contact area in the PV module. so we test the resistance on each case for analysis with common connection method. we measurement the electrical output characteristics and phenomenon of PV module that is applied new connetion method. by the result, The fill factor and electrical output characteristics on PV module are analyzed to getting better more then common connection method. Finally we recommend the developed connection method for diminishing of resistance on PV module. It enhance the electrical character more than common connection method.

  • PDF

The Analysis of missmatch with resistance on Si-PV module (결정질 태양전지 모듈 내부 저항의 Missmatch 분석)

  • Ji, Yang-Geun;Kong, Ji-Hyun;Kong, Gi-Hwan;Yu, Gwon-Jong;Won, Chang-Sub;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, we test the electrical resistance of flat wire in the PV module. normally solar cell has two kind of flat wire(inter connection ribbon and bus bar ribbon). we found the phenomenon that has a unbalance with resistance when we make a wiling between of string. So, we measurement the resistance of flat wire each other. and analysis of missmatch with resistance between flat wires on PV module. next to survey of IR picture on missmatch flat wire samples for analyze of missmatch with current in the wire. and we perform IR test with solar cell that has a connection with flat wire for test the effect of missmatch resistance on solar cell. Finally we perform the Dark I-V test for survey of effect by the unbalance of resistance. By the result of Dark I-V test, the series resistance of existing connection sample is large more then innovated connection sample.

  • PDF

Fire Prevention Systems for Photovoltaic Connection Panel (태양광 접속반의 화재 방지 시스템)

  • Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.137-138
    • /
    • 2019
  • The photovoltaic module connects the voltage generated by the solar cell to the inverter. In the photovoltaic module, a diode is used to block the reverse voltage from the inverter to the solar cell. The heat generation of this diode is the main cause of the solar connection fire. In this paper, we propose a method to monitor the heat generation of diodes and prevent fire by using IoT devices.

  • PDF

PV Module Configuration Considering Environment Conditions of Photovoltaic System (태양광 발전시스템의 환경조건을 고려한 PV 모듈 구성)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.31-41
    • /
    • 2014
  • This paper proposes the configuration of photovoltaic(PV) module considering the environment conditions of the PV system. The PV system is consisted of the series-parallel connection of the PV module. When shadows or changes of the radiation or an electrical characteristic in the solar cell are happened to PV system, the serious power loss will occur. If the PV module connected in series has the shadows, the output current is restricted to current of shaded PV module. Also if shadow is occurred to the parallel connection PV module, the output voltage is limited to voltage of shaded PV module. These problems are caused power loss. Therefore, this paper proposes the method that makes the output power of the PV module equalize by reconfiguration of PV module using the switching considering these environment conditions. A validity of the method proposed in this paper proves through comparing with performance of conventional PV module.

Optimum Design of Dye-Sensitized Solar Module for Building-Integrated Photovoltaic Systems

  • Lee, Kyu-Seok;Kang, Man Gu
    • ETRI Journal
    • /
    • v.39 no.6
    • /
    • pp.859-865
    • /
    • 2017
  • This paper presents a method for determining the optimum active-area width (OAW) of solar cells in a module architecture. The current density-voltage curve of a reference cell with a narrow active-area width is used to reproduce the current density profile in the test cell whose active area width is to be optimized. We obtained self-consistent current density and electric potential profiles from iterative calculations of both properties, considering the distributed resistance of the contact layers. Further, we determined the OAW that yields the maximum efficiency by calculating efficiency as a function of the active-area width. The proposed method can be applied to the design of the active area of a dye-sensitized solar cell in Z-type series connection modules for indoor and building-integrated photovoltaic systems. Our calculations predicted that OAW increases as the sheet resistances of the contact layers and the intensity of light decrease.

Fabrication of $CuInSe_2$ thin films Solar Cell by Patterning Process (Patterning에 의한 $CuInSe_2$ 박막 태양전지 제조)

  • Kang, Gi-Hwan;Lee, Jeong-Churl;Kim, Seok-Ki;Yoon, Kyung-Hoon;Park, I-Jun;Song, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1895-1897
    • /
    • 1999
  • This paper describes the fabrication and performance characterizations of the CIGS$(CuInGaSe_2)$ solar cells and its prototype module. The CIGS cell and module were fabricated on the sodalime glass$(5\times5cm^2)$ by the well known three stage co-evaporation and series connection followed by patterning process. respectively. The developed minimodule with active area of $14.7cm^2$ showed 6.0% solar efficiency($V_{oc}$=3.2V, $I_{sc}$=79.8mA, FF=34.6%) in AM 1.5 condition.

  • PDF

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.