• Title/Summary/Keyword: Radioimmunoassay

Search Result 453, Processing Time 0.022 seconds

Radioimmunoassay of High-Density Lipoprotein in Japanese Quail Serum (메추리혈청 리포단백질의 방사면역분석법)

  • 한병훈;한용남;유시용;양현옥;박명환
    • YAKHAK HOEJI
    • /
    • v.29 no.2
    • /
    • pp.90-95
    • /
    • 1985
  • The development of radioimmunoassay (RIA) for high-density lipoprotein (HDL) in Japanese quail serum will contribute to the screening of drugs acting on cholesterol transport. We have developed a double antibody RIA method for J. quail HDL. The first antibody was raised in rabbit by immunization of HDL isolated by the dextrane sulfate-$Mn^{#}$ precipitation method. For the preparation of raclioiodinated antigen, HDL was further purified by combination of electrophoretic procedure. Using the second antibody raised in goat by rabbit IgG, we have furnished the RIA method for HDL. It showed high specificity and sensitivity of working assay range, 0.1-33.mu.g HDL/tube. There was no correlation between the radioimmunoassay of HDL and the enzyme assay of HDL-cholesterol.

  • PDF

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

A Study on the Quality Control of the Radioimmunoassay Serum $T_3$(triiodothyronine) (혈청(血淸)$T_3$의 방사면역측정시(放射免疫測定時) 정도관리(精度管理)에 관(關)한 검토(檢討))

  • Kyong, Kwang-Hyon;Choi, Young-Sook
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.55-62
    • /
    • 1982
  • Measurement of triiodothyronine($T_3$) concentration is useful for the diagnosic and treatment of thyroid gland diseases. Fundermental studies of measurement of $T_3$ concentration by radioimmunoassay were performed and values determined by commercially available kit, Coat-A-Count, Diagnostic Products Corporation. The optimal utilization of the radioimmunoassay in measuring $T_3$ concentrations is dependant not only on high quality performance of the assay, but also on their appropriate application to the clinical situation. These are several aspects that must be considered in every individual case. These include factors such as accurate pippeting in reagent preparation in the assay and through decanting to remove all visible moisture after incubation steps and so forth. In attempt to assess quality control of the radioimmunoassay of serum $T_3$, serum pools with high, medium, low $T_3$ concentrations were assayed for each of 5 samples. The results obtained with this study were as follow: 1. The coefficient of variation(C. V.) for the standard curve ranged between $0.2{\sim}3.5%$. 2. It was necessary that both incubation time and temperature should correctly be maintained all the in the assay performance. 3. The precison with the $T_3$ RIA procedure was good. 4. The measured values of serially diluted serum $T_3$ concentration with Ong/dl standard solution was proportional to the predicted values. However dilution curve of distilled water was not strait. 5. Calculated $T_3$ values of patient serum in normal group was $107.8{\pm}25.90ng/dl$ in male patient and $127.29{\pm}24.08ng/dl$ in female patient.

  • PDF

Production and Characterization of Specific Antibodies to Bombesin

  • Kwon, Hyeok-Yil;Lee, Yun-Lyul;Park, Hyoung-Jin
    • The Korean Journal of Physiology
    • /
    • v.28 no.1
    • /
    • pp.91-97
    • /
    • 1994
  • In order to produce a specific bombesin antiserum far very sensitive radioimmunoassay, synthetic $[lys^3]-bombesin$ conjugated to bovine serum albumin was subcutaneously injected into guinea pigs. The conjugation was performed using either carbodiimide or gIutaraldehyde as a coupling agent. The antisera were characterized by analysis of Scatchard and Sips plots. The antiserum LBE 2G/2 raised by repeat injection of the immunogen conjugated with carbodiimide showed the titer of 1 : 188,000, very low cross-reactivity to bombesin-like peptides except bombesin, with high affinity constant $(1.64{\times}10^{11}\;M^{-1})$ and high heterogeneity index (0.91). The antiserum LBG 1G/2 produced by repeat injection of the immunogen conjugated with glutaraldehyde possessed the titer of 1 : 43,000, high cross-reactivity to some bombesin-like peptides, high affinity constant $(1.19{\times}10^{11}\;M^{-1})$ and high heterogeneity index (0.79). These results indicate that the antiserum LBE 2G/2 is specific only to bombesin and that the antiserum LBG IG/2 binds to some bombesin-like peptides such as alytesin, gastrin releasing peptide and neuromedin C. The antiserum LBE 2G/2 is sufficient for the very sensitive radioimmunoassay of bombesin.

  • PDF

Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range (BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언)

  • Park, Hee-Won;Kim, Tae-Hoon;Roh, Gyeong-Un;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.108-114
    • /
    • 2012
  • Purpose: Immunosorbent assay most commonly used in the laboratory and commercial third-party quality control material is a substance that provided by BIO-RAD. However, in Reference Sheet by radioimmunoassay test kit or a measuring device for the mention of Acceptable Range is somewhat lacking. Radioimmunoassay for the inspection of test results by setting Acceptable Range to increase the objectivity of the recommendations on the data accumulated by the manufacturer listed in the Reference Sheet is to be issued. Materials and Methods : In our hospital since 2009 partially BIO-RAD using quality control materials in 2011, excluding certain items, some items were most of the BIO-RAD third-party quality control materials are used. Thus, internal quality control data accumulated BIO-RAD's Unity Real Time program by using the items were measured. Results : BIO-RAD using quality control material items were about 50 of the 20 Point Data averages, standard deviations, variation coefficients were calculated to measure the Acceptable Range of kit, automated immunoassay attributed Roche Elecsys / E170 / cobas e Systems the measures and compared. Conclusions : BIO-RAD QC materials commonly used hospital and peer group by setting the measurement kit, suitable for laboratory equipment for radioimmunoassay of Acceptable Range manufacturer recommendation to increase the objectivity of the test results by national and international recognition for radioimmunoassay should seek to increase.

  • PDF

Performance Characteristics of CA 19-9 Radioimmunoassay and Clinical Significance of Serum CA 19-9 Assay in Patients with Malignancy (CA 19-9 방사면역측정법의 기본적 검토 및 악성종양환자에서의 혈청 CA 19-9치의 임상적 의의에 관한 연구)

  • Kim, Sang-Eun;Shong, Young-Kee;Cho, Bo-Youn;Kim, Noe-Kyeong;Koh, Chang-Soon;Lee, Mun-Ho;Hong, Seong-Woon;Hong, Kee-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.119-126
    • /
    • 1985
  • To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. The results were as follows; 1) The CA 19-9 radioimmunoassay was simple to perform and can be completed in one work day. And the between-assay reproducibility and the assay recovery were both excellent. 2) The mean serum CA 19-9 level in 135 normal controls was $8.4{\pm}4.2U/mL$. Normal upper limit of serum CA 19-9 was defined as 21.0 U/mL. 4 out of 135(3.0%) normal controls showed elevated CA 19-9 levels above the normal upper limit. 3) One out of 20(5.0%) patients with benign gastrointestinal diseases showed elevated serum CA 19-9 level above the normal upper limit. 4) In 81 patients with various' untreated malignancy, 41 patients(50.6%) showed elevated serum CA 19-9 levels. 66.7% of 18 patients with colorectal cancer, 100% of 2 patients with pancreatic cancer, 100% of 3 patients with common bile duct cancer, 47.1% of 17 patients with stomach cancer, 28.6% of 28 patients with hepatoma and 60.0% of 5 other gastrointestinal tract cancers showed elevated serum CA 19-9 levels. 5) The sensitivities of serum CA 19-9 related to resectability in colorectal and stomach cancer were 33.3% in resectable colorectal cancer, 83.3% in unresectable colorectal cancer, 41.7% in resectable stomach cancer, 60.0% in unresectable stomach cancer respectively. 6) The sensitivity of serum CA 19-9 in 9 patients of postoperative colorectal cancer without recurrence were 33.3% and significantly decreased compared with that of untreated colorectal cancer, 66.7% (p<0.05). 7) In patients with colorectal cancer, simultaneous measurement of serum CA 19-9 and serum CEA levels increased sensitivities. From above results, we concluded that serum CA 19-9 radioimmunoassay is simple to perform and reproducible, and is a useful indicator reflecting tumor extent and responses to the treatment in patients with malignancy.

  • PDF